Search

51 products
View:
  • Selected: 0
    Applying
  • Selected: 1
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • 2
    Applying
  • Names
  • 3
    Manufacturer
  • 4
    Made in
  • 2
    Additional
View:
51 products
Vacuum membrane pump PL.HM03.02.60 Primelab
Vacuum membrane pump PL.HM03.02.60 Primelab
from 100 000 ₽
1 supp.
The vacuum pump chamber is made of fluoroplastic, and other parts are coated with fluoroplastic, which ensures the high chemical resistance of the pump. It has a pumping speed of gases and vapors of 38 l/min at an extreme vacuum of 60 mbar. It is quite compact, so it can be placed in almost any already equipped space. Valve(s) material FFKM (Perfluoro rubber) Working medium Gas Country Russia Chemical resistance Yes Overall dimensions, L×W×H, mm 289.5x160x200 Protection class acc. to DIN EN60529 IP20 Noise level, dB 75 dB Power supply 230 V, 50 Hz Ultimate vacuum, mbar abs. 60 Excess pressure, bar. Max. permissible 0.5 bar Productivity, l/min 38 Drive rotation speed, rpm 1350 Maximum current, A 1.2 Device weight, kg 7.6 Working chamber material PTFE (polytetrafluoroethylene) Equipment: Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
2VVN1-25 water ring vacuum pump
2VVN1-25 water ring vacuum pump
The use of a 2VVN1-25(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-25(H) pump. The 2VVN1-25(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
2NVBM-250/3000 Booster high vacuum pump
2NVBM-250/3000 Booster high vacuum pump
The 2NVBM-250(R)/3000 booster pump consists of housings, a steam pipe, a trap and a heater. The alignment of the steam line in the pump housing 2NVBM-250(R)/3000 is carried out by a steam line screed, which, when installing the housing on the collector, enters its upper end into the hole of the hood (oil reflector). The required effective speed of action of the forevacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-250(R)/3000 booster pump is not less than 25 l/s. The maximum residual pressure of the 2NVBM-250(R)/3000 pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6 × 10-4 Pa (5 × 10-6 mm Hg). The pressure of the cooling water at the inlet to the 2NVBM-250(R)/3000 pump should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2). The drain from the pump must be free with a jet break. Cooling water consumption is 360 l/h. The total amount of working fluid for the 2NVBM-250(R)/3000 pump is 17 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1 · 10-2 to 1 · 10-1 mm Hg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Vacuum turbomolecular complex KW-150
Vacuum turbomolecular complex KW-150
The complex includes: single-flow turbomolecular vacuum pump VGTN-150; frequency converter; set of mounting parts; operation manual. For connecting to the pre-vacuum pumping system, the pump is equipped with an ISO-KF25 exhaust flange. If necessary, it can be upgraded with an ISO-KF16 flange for purging the pump with inert gas. Pump cooling is combined. Based on the operating conditions, the complex can work both with forced air cooling and with water cooling. The working orientation in space is arbitrary. One of the key features of the pump is that a breakthrough of the atmosphere is possible. This has become possible due to the production of a turbine from a solid billet and a special, rigid design of the bearing assembly.
Produced in: Vladimir
3VVN1-12M Water ring vacuum pump
3VVN1-12M Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-12M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working parts. The 3VVN1-12M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-12M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
NVD-600 Two-rotor Vacuum Pump
NVD-600 Two-rotor Vacuum Pump
The NVD-600 two-rotor vacuum pump is not designed for pumping air, vapors and vapor-gas mixtures from one volume to another. The NVD-600 two-rotor pump can only work in conjunction with a pre-vacuum pump, and is designed for pumping in the pressure range from 1.3·102Pa (1 mm Hg) to the maximum residual pressure. The speed of action of the forvacuum pump for NVD-600 is not less than 60 m3/h. The temperature of the pumped media at the inlet to the pump NVD-600 should not exceed the maximum operating values of the ambient temperature according to GOST standard 15150-69, at which the pump is operated. At an operating pressure of more than 5 mm Hg for the HVD-600, the bypass valve is in the open position. The pumped gas is partially bypassed through channels in the pump housing from the outlet to the inlet of the pump NVD-600, which ensures the operability of the pre-vacuum pump and prevents overheating of the pump NVD-600. The NVD-600 double-rotor vacuum pump can operate continuously at an inlet pressure of no more than 133 Pa (1 mm Hg) or pumping out one or more sealed vessels with a total volume of 7.5 m3 for the pump from atmospheric to the maximum residual pressure for 8 hours.
Produced in: Kazan
Vacuum membrane pump PL.HM02.01.4 Primelab
Vacuum membrane pump PL.HM02.01.4 Primelab
from 250 000 ₽
1 supp.
The vacuum membrane pump PL.HM02.01.4 is a universal device made in Russia from the Primelab company. Made from high-quality materials, including fluoroplastic, used to create sealed chambers, and a protective coating for safe operation of the device. The technical characteristics of the pump depend on the method of connecting the chambers. With a series connection, the performance will be 38 l/min at a maximum vacuum of 4 mbar. Parallel and independent connections will allow you to achieve completely different performance indicators of the device. The vacuum diaphragm pump PL.HM02.01.4 Primelab is convenient to use. It has a light weight of 9 kg, compact dimensions (321.5x160x200 mm) and creates a minimum of noise (up to 75 dB).
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
ND-630 High-vacuum diffusion pump
ND-630 High-vacuum diffusion pump
The working condition of the ND-630 diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (uner technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-630 diffusion pump is a maximum of 9 liters, a minimum of 6 liters. The viewing window for visual inspection of the working fluid has marks of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid practically does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-630 diffusion pump using one temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the ND-630 diffusion pump up to 360°C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 600 l/h, for the oil reflector it is 80 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
Vacuum membrane pump PL.HM02.01.8 Primelab
Vacuum membrane pump PL.HM02.01.8 Primelab
from 165 000 ₽
Vacuum membrane pump PL.HM02.01.8 Primelab is a universal laboratory device, the performance of which can be adjusted for each task separately. Depending on the method of connecting the chambers, its productivity can be 38 l/min and 76 l/min with a maximum residual pressure of 8 and 45 mbar. With independent connection, 38 l/min for each chamber. A carefully thought out security system ensures a long service life of the device. Complies with IP20 protection class. It makes virtually no noise during operation (up to 75 dB), which does not cause discomfort when the pump is constantly running. It has small dimensions (321x140x200 mm), allowing the device to be placed in an already equipped space. Supplied complete with equipment sufficient for quick assembly and operation of the device.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
NVSp-4 Spiral Vacuum Pump
NVSp-4 Spiral Vacuum Pump
The NVSp-4 dry vacuum spiral pump can operate continuously at an inlet pressure of no more than 10 kPa (75 mm Hg), pumping out one or more sealed vessels with a total volume of no more than 0.7 m3 from atmospheric to residual pressure during the day. Pumping of vessels of the specified volume with leakage is allowed, but the leakage should not cause an increase in pressure at the pump inlet of more than 10 kPa (75 mm Hg).
Produced in: Kazan
Vacuum membrane pump PL.HM01.01.6 Primelab
Vacuum membrane pump PL.HM01.01.6 Primelab
from 180 000 ₽
1 supp.
Vacuum membrane pump PL.HM01.01.6 Primelab is a compact, chemical-resistant and efficient laboratory device made in Russia. Designed to create a vacuum, drying and filtration under vacuum conditions, as well as pumping steam-gas-air media. The Primelab company has developed a pump in accordance with IP20 protection class. Absolutely safe: its chambers are made of fluoroplastic, the connections are covered with a fluoroplastic coating. Productivity is 38 l/min at a maximum vacuum of 6 mbar. In operating mode, the noise level does not exceed 75 dB. In Russia, the Primelab vacuum diaphragm pump PL.HM01.01.6 is subject to warranty and post-warranty service. Supplied complete with everything you need to get started.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region