Search

329 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 8
    Applying
  • 45
    Names
    Loading...
  • 2
    Manufacturer
  • Made in
  • 8
    Additional
View:
329 products
Temperature equalization unit THERMOTEST-B1
Temperature equalization unit THERMOTEST-B1
It is designed to improve short-term temperature stability during verification and calibration of electronic thermometers LT 300 (except LT-300-F), LT and ExT-01/1 in calibration thermostats TERMOTEST 100, TERMOTEST-100-40, TERMOTEST 05 and TERMOTEST-05-1.
Produced in: Tomsk
Stand MTIf-P
Stand MTIf-P
The stainless steel stand is designed for installation and storage of pressure gauges MTIf 100, MTIf 160 and MTIf 400 in the process of determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products. Overall dimensions 170x95x105 mm Weight 0.5 kg
Produced in: Tomsk
Heat carrier PMS-50
Heat carrier PMS-50
Polymethylsiloxane liquid for the operating temperature range 0...+200 °C. In aluminum cans it is supplied with a volume of 10 liters. The density is 0.960 g/cm3.
Produced in: Tomsk
CRYO-VT-12-1 Low-temperature liquid thermostat
CRYO-VT-12-1 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the internal bath of the thermostat and in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 360 W at +20 °C. Internal bath with a volume of 6 liters and a depth of 140 mm. The operating temperature range is -30...+200 °C. Overall dimensions 280x460x620 mm The open part of the bath is 110x80 mm Bath depth 140 mm Weight 39 kg Power consumption 3.0 kW.
Produced in: Tomsk
Storage cabinet for gas (oxygen) cylinders SHDB-40.40.182
Storage cabinet for gas (oxygen) cylinders SHDB-40.40.182
Cabinet 400 mm wide, 1825 mm high made of painted steel for storing one cylinder with a capacity of 40 liters. Overall dimensions 400x400x1825 mm Weight 36 kg
Produced in: Tomsk
LB22-Sh Laboratory bath
LB22-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases when high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. One workplace with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 5 liters and a depth of 110 mm. The volume of the bath is 5 liters Overall dimensions 515x360x660 mm The open part of the bath is 295x145 mm Bath depth 110 mm Weight 7 kg Power consumption 2.5 kW
Produced in: Tomsk
Dry-air low-temperature thermostat BIOTEST
Dry-air low-temperature thermostat BIOTEST
Operating temperature range +10...+30 °C. Instability of maintaining the set temperature ± 0.5 ° C. Overall dimensions 480x620x1070 mm Weight 33 kg Power consumption 200 W
Produced in: Tomsk
Silicone hose 18x3 with thermal insulation
Silicone hose 18x3 with thermal insulation
Silicone hose with thermal insulation and an internal diameter of 18 mm is used to connect the CRYO-VT-07 thermostat or A600 circulation cooler to external consumers.
Produced in: Tomsk
Laboratory electronic thermometer LTA-N
Laboratory electronic thermometer LTA-N
The error is ± 0.05 °C in the range of -50...+300 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Glass cylinder VT-ro-TS
Glass cylinder VT-ro-TS
Glass cylinder for hydrometers of the size 50×500 mm. Designed for thermostats VT RO 01, VT RO 02 and CRYO-VT RO 03.
Produced in: Tomsk
Fume Cupboard SHV-NRZH.240
Fume Cupboard SHV-NRZH.240
Overall dimensions with raised protective shield 2405x800x2270 mm Overall dimensions with lowered protective shield 2405x800x2100 mm The diameter of the exhaust pipe is 200 mm Weight 386 kg Power supply 220 V, 50 Hz, 16 A
Produced in: Tomsk
Set of devices for BNTI-05-04 State Standard 20287 method B
Set of devices for BNTI-05-04 State Standard 20287 method B
It is used in determining the pour point of petroleum products in accordance with the State Standard 20287 (method B).
Produced in: Tomsk