DWDM Modules
DWDM Modules
DWDM SFP transceivers support various data transfer protocols, ranging from OS-3/STM-1/SDH/FE to 10GBE/OC-192/10FC/STM-64. All Optronic DWDM transceivers are equipped with DDM (Didgital Diagnostic Monitoring). This function allows you to control the parameters of optical modules: output signal power, input signal power, temperature characteristics of the transceiver, as well as supply voltage and consumption current. The data is transmitted in real time.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Hinged cabinet LAB-M NSHS-2 80.35.70
Hinged cabinet LAB-M NSHS-2 80.35.70
Furniture for laboratory work. Mounted storage cabinet Length, mm: 800 Depth, mm: 350 Height, mm: 700 PACKAGE CONTENTS body – melamine white 16 mm thick, ABS edge dark gray two compartments facades – tinted light gray glass in the right compartment 1 built-in shelf, in the left compartment 1 easily removable shelf with the possibility of rearrangement at 5 levels in height permissible load on the shelf - 20 kg.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Table-sink LAB-M MO 120.65.90 T6V
Table-sink LAB-M MO 120.65.90 T6V
Furniture for laboratory work. Table-sink LAB-M MO 120.65.90 T6V Width, mm: 1200 Depth, mm: 650 Height, mm: 900 equipment: Table top – TRESPA TopLabPlus – monolithic slab of ultra-high pressing thickness of 6mm with a chemically resistant surface made of polyurethane-acrylic composition, on a substrate of wood-containing material (plywood 15mm or melamine 16mm), edged around the perimeter of PVC edge 2mm 1 built–in bowl - epoxy compound VITE. The location of the bowl in the center, fixing the bowl flush with the level of the countertop. Inner bowl size – 450*365*280 mm The base of the sink table is a support pedestal made of white melamine Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging Without shelves
LOIP
Saint Petersburg
Produced in: Saint Petersburg
8-CHANNEL PORTABLE RECORDER OF EMERGENCY AND NORMAL MODES PARMA RAS VAF-A(M2)
8-CHANNEL PORTABLE RECORDER OF EMERGENCY AND NORMAL MODES PARMA RAS VAF-A(M2)
It will help relay protection and automation services, the chief power engineer of industrial enterprises and a wide range of specialists engaged in setting up, monitoring, diagnostics and operation of electrical installations to solve the following tasks: − record emergency waveforms on 4 current channels and 4 voltage channels, with data stored in COMTRADE format - take daily load schedules and carry out long−term monitoring of the parameters of the power grid (recorder) - to monitor the conduct of switching in switchgear − identify the causes of the emergency mode − to evaluate the correctness of the operation of the RSiA and PA devices − determine the harmonic composition of current and voltage (up to and including the 14th harmonic) − control phase alternation − remove the voltage characteristics − measure the phase shift angle and perform the construction of vector diagrams of voltage and current − control the circuits in the SHPT − check the integrity of electrical conductors (ringing) − carry out maintenance of relay protection circuits and power circuits of electrical installations − monitor the status and diagnostics of DC circuits
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range (with crucible cooling), °C from +40 to +400* The heating rate of the crucible with the sample, °C/min 0..20 Igniting a gas flame The speed of the stirrer, rpm 30...240 Power consumption from AC 220 V, no more, 600 W Overall dimensions of the device, not more than 350x250x280 mm Weight of the device, not more than, kg 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Island LAB table-2400 OKM
Island LAB table-2400 OKM
equipment 2 countertops sink-drain (polypropylene, internal size 250*100*150mm), laboratory faucet d/water the package includes a siphon corrugated hose flexible eyeliner length 1200mm 2 racks, each support racks – aluminum profile painted with powder paint (RAL 1001) top panel 190mm deep – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sliding cabinet LAB-400 TNYA-3
Sliding cabinet LAB-400 TNYA-3
Furniture for laboratory work. Sliding cabinet Length, mm: 400 Depth, mm: 580 Height, mm: 680 PACKAGE CONTENTS case – melamine 16mm thick inner size of the box – 310*470* 120mm roller supports h=60mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted table LAB-1200 PLTM
Wall-mounted table LAB-1200 PLTM
equipment sink-drain (polypropylene, internal size 250*100*150mm), laboratory faucet for water the scope of delivery includes a siphon corrugated hose flexible liner length 1200mm rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel depth 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Mercury analyzer "RA-915M" with the prefix "RP-92"
Mercury analyzer "RA-915M" with the prefix "RP-92"
1 supp.
Technical specifications: Continuous operation time 8 hours Analyzer dimensions (LxWxH), mm, no more than 470x110x220 mm Overall dimensions of the pumping unit: (LxWxH), mm, no more than 360x110x125 mm Analyzer weight 7 kg The weight of the console is 7 kg Power supply 100 - 240 V Powered by an autonomous RA source-915+ - 6/14 In Powered by an autonomous source RP-91 - 12 V Power consumption 20 W Current frequency 50/60 Hz The mass of the pumping unit is 3 kg Average service life, years, at least 5 Volume of the injected sample, cm3 0.5 - 10.0 Air flow, dm3/min 0.8 - 4.2
Lumeks
Saint Petersburg
Produced in: Saint Petersburg