Search

1188 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 22
    Areas of use
    Loading...
  • 161
    Item names
    Loading...
  • 24
    Manufacturer
    Loading...
  • Made in
  • 42
    Additional
    Loading...
View:
1188 products
Muffle furnace LF-15/11-V2
Muffle furnace LF-15/11-V2
Design features: Special system of air intake and exhaust of combustion products with adjustable thrust; Programmable microprocessor temperature controller; Three programs of ten steps with the ability to set the temperature, heating speed and holding time for each step; Manual heating mode with timer with sound notification and auto-off; Durable ceramic muffle; Closed heaters on four sides of the chamber; Backlit graphic display; Conveniently located control panel; Automatic shutdown of heating when opening the door; Sound and light alarm when the current temperature exceeds the limits of the permissible interval; The door opens up and faces the user with the cold side; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1100 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than mm 215x190x330 Overall dimensions, WxHxD, not more than 525x1045x680 mm Rated supply voltage, 220 V Rated power, W 6100
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted LAB table-1200 PF
Wall-mounted LAB table-1200 PF
COMPLETE SET rack support posts – aluminum profile, powder-coated (RAL 1001) top panel 190mm deep – metal, powder-coated (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Thermostat for determining oxidative stability LT-830
Thermostat for determining oxidative stability LT-830
Design features: Microprocessor-based PID controller; Multifunctional control knob; Minimum temperature gradient over the entire volume of the bath; Hole for the control thermometer; Stainless steel bathtub ; Built-in cooling heat exchanger; Self-diagnosis system; A faucet for draining the working fluid. Technical specifications: Temperature range, °C - without external cooling - with cooling with tap water (current +10)...+100 (Tvods+5)...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of test places 4 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 30 Working fluid - up to 80 °C - above 80 °C distilled water water-glycerin mixture Overall dimensions (WxDxH), mm 560x250x710 Weight of the device without liquid, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory Mill CALIBRE
Laboratory Mill CALIBRE
1 supp.
The mill provides grinding of agricultural crops according to the current standards regulating methods of determining their quality. Principle of operation: grain is fed into the mill dispenser, where an air-grain mixture is formed, which enters the grinding chamber. The crushed product is separated from the air in the cyclone and collected in a special removable container. After the grain supply is stopped, the air flow ensures self-cleaning of the dispenser and the grinding chamber of the mill. application It is used in the preparation of samples to determine the quantity and quality of gluten, the "drop number" and other indicators of the quality of crops by infrared spectroscopy and other laboratory analysis methods, which require a high degree of grinding of samples. The CALIBRE differs from its predecessor, the BOREY laboratory mill, by a drastic reduction in overall and weight characteristics. An additional advantage of the CALIBRE mill is the reduction in the number of structural elements. So the absence of the door of the grinding unit makes it possible for quick access to carry out work on cleaning the grinding headset. technical specifications: Volume of the receiving funnel, ml 400 Permissible amount of ground product per hour, kg 3 The grinding time of the suspension is 50 gr., from 25-35 The maximum size of the crushed product, mm 12 The diameter of the sieve holes, mm 0.8; 1.0 The speed of rotation of the grinding hammers, rpm 16 500 Minimum mass of the milled product, g 10 The maximum mass of the milled product, g 300 Overall dimensions, mm 400 x 445 x 400 Weight, kg 26 Noise level, dB 70 Power supply Single-phase AC 220 V, 50 Hz Power, W 1050 The response time of the overload protection system, from 2 GENERAL CHARACTERISTICS: 1. Reproducible sample preparation process: The mill is equipped with a sieve with round holes with a diameter of 0.8 mm*, which makes it possible to obtain a finely dispersed product with a stable particle size during grinding. On a separate order, it is possible to complete a sieve with holes with a diameter of 1.0 mm. 2. Quick and easy cleaning The cyclone-exhaust system of the mill provides self-cleaning of the grinding chamber. The ledges and holes in which the ground sample can be collected are minimized. 3. Low noise The vibration and noise insulation system of the CALIBRE mill allows, with considerable power and productivity, to ensure comfortable work of personnel during the working shift. 4. Maximum safety and ease of operation The closed grinding chamber ensures safe operation of the mill. The thermal overload protection system turns off the electric motor when it stops during the grinding process.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted table LAB-1500 PFT
Wall-mounted table LAB-1500 PFT
EQUIPMENT rack support racks – aluminum profile painted with powder paint (RAL 1001) top panel with a depth of 190mm – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory washing table CM-150.64.90
Laboratory washing table CM-150.64.90
A table with an overall height of 900 mm with a countertop measuring 1500 × 640 mm made of porcelain stoneware, monolithic ceramics or stainless steel. It is designed for long-term operation, the power frame does not contain aluminum and plastic parts in the fasteners. Overall dimensions without superstructure 1500x640x900 mm
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Low laboratory work table LAB-PRO SLn 150.65.75 TR
Low laboratory work table LAB-PRO SLn 150.65.75 TR
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Automatic apparatus for analysis of saturated vapor pressure of liquid petroleum products DNP-LAB-12
Technical specifications: The volume of the analyzed sample is 5 ml The volume of the test chamber is 25 ml Test temperature 37.8°C Accuracy of maintaining the temperature of the chamber ±0.1 °C Pressure measurement range 0.01...200 kPa Pressure measurement accuracy ±0.01 kPa Gas/liquid ratio 4/1 Power consumption from 220 mains, no more than 150 watts USB, LAN interface Overall dimensions, no more 450x230x190 mm Weight, not more than 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 150.86.230 PP
Supply and exhaust cabinet with drainage system for working with fuming acids LAB-PRO SHPVK 150.86.230 PP
BASIC EQUIPMENT Working box front guide posts – aluminum profile painted with powder paint (RAL 7035/RAL 5023), in the right rack there are a light switch and 2 splash–proof sockets with a 3.2kW cover (IP54) front anti–spill side - polypropylene working surface - polypropylene 15mm thick removable plate 600*600mm with a ceramic granite work surface for placement heating plates (2 pcs.) 2 dependent lifting screens filled with transparent PVC, 5mm thick in a polypropylene frame in the lower screen – sliding doors made of transparent PVC with a thickness of 5mm lifting 0-780mm, does not change the dimensions of the cabinet when lifting the counterweights are placed in the front pillars-pylons and are easily serviced upper fixed screen – polypropylene inner part the working box is a fully sealed polypropylene capsule with a back wall washing system, a drainage channel and a polypropylene pipe for cold water 3 levels of hoods easily removable polypropylene exhaust canopies polypropylene drain sink on the top panel are placed: LED dust- and moisture-proof lamp (2X22W IP65) separated from the workspace by transparent PVC switching box with automatic emergency power off 16A flange with damper plug for air inflow d=200mm flange with aspiration collector for air outflow d=250mm (distance from the rear panels up to the center of the flange – 155mm) cabinet ventilation system
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Green DPSS Laser 523 nm KLM-523-x
Green DPSS Laser 523 nm KLM-523-x
DPSS lasers of the KLM-523/x series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Circulation thermostat LT-411b
Circulation thermostat LT-411b
The LOIP LT-411b modification device consists of an immersion thermostat-circulator LOIP LT-400 and a working bath with a lean-to hinged lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.01 The error of setting the set temperature, not more than, ° C ± 0.02 Heater power, W 2200 Pump: max. flow rate, l/min 6...12 pressure, 0.4 bar Bath volume, l 11 The working fluid is water, silicone oil. The open part of the bath / depth, mm 165x230/200 Overall dimensions, mm 268x335x400 Weight, kg 11.4
LOIP
Saint Petersburg
Produced in: Saint Petersburg