Search

1188 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 22
    Areas of use
    Loading...
  • 161
    Item names
    Loading...
  • 24
    Manufacturer
    Loading...
  • Made in
  • 42
    Additional
    Loading...
View:
1188 products
Heating plate LH-405
Heating plate LH-405
Maximum heating temperature, °C 400 Temperature difference across the platform, °C, no more than ± 5 Dimensions of the heating platform, mm 218x315 Power consumption, W 1800 Platform material aluminum alloy Overall dimensions, mm 285x370x110 Weight, kg 9
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Cryothermostat liquid FT-205-25
Cryothermostat liquid FT-205-25
Technical specifications: Operating temperature range, °C -25...+100 Accuracy of temperature maintenance, °C ± 0.2 The discreteness of the temperature display, ° C 0.1 Cooling capacity at 20°C, W 470 Pump capacity in the discharge circuit, not less than, l/min 10.5 Volume of working fluid, l 6.5 The open part of the bath/depth, mm dia.80x200 Power supply, V/Hz 220/50 Power consumption, not more than 3.6 kW Overall dimensions, mm 320x465x590 Weight without working fluid, kg 20
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Specialized X-ray wavelength dispersive analyzer ARF-7
Specialized X-ray wavelength dispersive analyzer ARF-7
Specialized wavelength-dispersive XRF analyzer based on the Cochois scheme is designed for high-precision determination of chemical elements U, Th, Mo, Au, W, Tl, As, Pb as well as other elements in ores, rocks and when developing the technogenic fields. Possibility to determine groups of elements without readjustment of crystal-analyzer. Exceptionally high resolution of the Koshua X-ray optical scheme with crystal-analyzer quartz 1011. Developed mathematical support. Principle of analyzer operation is based on the excitation of the fluorescent radiation of sample atoms being under examination by radiation coming from an X-ray tube. Spectrum decomposition of the fluorescence radiation is performed according to Cauchois method. The fluorescence radiation focused by analyzing crystal and standard line are marked on Rowland focal circle. Then, they are recorded by X-ray radiation detector in turn. The intensity of the fluorescent irradiation with a particular wavelength is directly proportional to the chemical element concentration in the material under examination.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Oxygen generator "VPSA series"
Oxygen generator "VPSA series"
An oxygen adsorption generator is a special equipment designed to produce gaseous oxygen from atmospheric air by short—cycle non-heating adsorption. The main components of the generator are: adsorbers (vessels operating under excessive pressure) filled with zeolite molecular sieve, pneumatic valves, automatic control system, shut-off and control valves and other control and measuring devices, and equipment. Oxygen concentration: 30-95% Capacity: 500-3000 m3/hour
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Laboratory LAB table-1800 LLv
Laboratory LAB table-1800 LLv
equipment side decorative panels – melamine 16mm thick all-welded frame made of rectangular metal profile painted with white powder paint adjustable supports
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Anemometer AP1M with cup sensor AP1M2
Anemometer AP1M with cup sensor AP1M2
from 47 332 ₽
Range: 0.8-20.0 m/s; Accuracy characteristics: PG±(0.3+0.05V) m/s; The power is supplied from a 4.8 V battery. The power consumption is 0.1 VA. Application conditions: For primary measuring transducers: from minus 30C to plus 50C in the range of 1.0–20.0 m/s; For digital measuring console: from minus 10C to plus 50C; Relative humidity 45-80% at temperature (25±10)With; Continuous operation time at negative temperatures up to minus 30C is no more than 1 hour.
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
Wall-mounted high table LAB-PRO SPCv 120.80.90 TR-E16/23
Wall-mounted high table LAB-PRO SPCv 120.80.90 TR-E16/23
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-210S
Laboratory scales VLTE-210S
from 59 990 ₽
Technical characteristics: NIP, G210 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g on ±10; sv. 200g to 210g on ±15 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Heating mantleLH-225 (50-250 ml)
Heating mantleLH-225 (50-250 ml)
The volume of the heated flask, ml 50-250 Maximum heating temperature, °C 600 Dimensions, mm 170x230x160 Power, W 550 Weight, kg 3
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Island LAB table-3000 OL
Island LAB table-3000 OL
equipment 2 tabletops, each tabletop consists of 2 cohesive parts, the seam is treated with moisture-resistant glue 2 racks, each support racks – aluminum profile painted with powder paint (RAL 1001) top panel 190mm deep – metal painted with powder paint (RAL 1001)
LOIP
Saint Petersburg
Produced in: Saint Petersburg