Search

119 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 11
    Applying
  • 38
    Names
    Loading...
  • 3
    Manufacturer
  • Made in
  • 4
    Additional
View:
119 products
pH-metrMARK® 902 / MARK® 902A
pH-metrMARK® 902 / MARK® 902A
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Control of water-chemical regimes at thermal and nuclear power facilities. pH control of aqueous media in technological processes.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic thermal compensation. Calibration according to standard buffer solutions with their automatic determination. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 409 A
Oxygen meter MARK® 409 A
Continuous measurement of dissolved oxygen concentration and temperature of aqueous media with excessive hydrostatic pressure.Two independent measurement channels Freely programmable measurement ranges Stability of operation with changes in hydrostatic pressure Permissible short-term (up to 5 min) pressure overload (water hammer) up to 40 MPa High reaction speed. The time to establish the analyzer readings is 2 minutes. Easy and quick replacement of the membrane The sensor is not afraid of "drying out" The content of dissolved hydrogen in the analyzed medium is taken into account The grading interval is 1 month The verification interval is 24 months
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 302 T
Oxygen meter MARK® 302 T
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Operational control of water-chemical regimes at thermal and nuclear power facilities.Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor | The service life of the sensor is at least 10 years. High contrast LCD indicator | Low power consumption | Up to 2000 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 3010
Oxygen meter MARK® 3010
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Operational control of water-chemical regimes at thermal and nuclear power facilities. Warranty 24 months for deliveries across the Russian Federation Measurement error ± (0.001+0.04 *A) mg/dm3 (A is the measured value). The ability to work on small flows (from 20 ml / min). Air oxygen calibration is not more than 1 time per month. Routine maintenance 1 time per year. Universal mechanism for direct connection to the process. NEW highly stable sensor High reaction speed. Sealed heavy-duty hydrophobic membrane. Increased mechanical strength of the structure. "Sleep" mode when stored in the air. Organic high contrast LED indicator Full protection from dust and moisture – housing-case IP65 Built-in long-lasting LiFePO4 battery (at least 1000 charge/discharge cycles) Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Amplifier module MUS-04
Amplifier module MUS-04
The module uses connectors of the SMA type. At the request of the customer, any combination of output signals is possible. When installing two amplifier modules in the above devices, the total number of output signals increases to twelve.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Frequency comparator CHK7-1011
Frequency comparator CHK7-1011
Frequency comparators CHK7-1011 and CHK7-1011/1 can also be used as frequency and time standards with frequency correction based on GLONASS/GPS signals as sources of highly stable signals in various frequency measuring systems. Comparators have a built-in device for processing measurement data based on a microcomputer, which provides statistical processing of the results of frequency and time measurements, and a device for displaying information based on a color TFT display. The built-in diagnostic system allows you to quickly determine the operability and condition of the main comparator devices with information output to the built-in display screen. Comparators are available in three versions and differ in composition and functions performed. Comparators have a basic set of devices (modules), including a frequency comparator, a power supply module and a device for processing and displaying information based on a microcomputer and a color TFT display. The frequency comparator CHK7-1011 has a built-in SRNS receiver and a highly stable rubidium frequency standard Ch1-1014 with the function of correcting the actual frequency value by signals from satellite radio navigation systems GLONASS or GPS. The comparator forms its own time scale with the ability to synchronize on any external time scale received by the SRNS receiver built into the device. The device has two modes for measuring the deviation of the generated time scale: from the time scale of the built-in SRNS receiver and from the external time scale. Information about the current time received from the SRNS receiver is displayed on the comparator display screen, and is also transmitted to the consumer via the RS-485 interface. All the above-mentioned features make the frequency comparator CHK7-1011 a unique measuring device in the field of frequency and time measurements. The frequency comparator CHK7-1011/1 has a highly stable rubidium frequency standard Ch1-1013 and can be used as a frequency and time standard as a source of highly stable signals in various frequency measuring systems. The frequency comparator CHK7-1011/2 does not include any additional devices. To carry out measurements with it, it is necessary to use a highly stable signal of the reference frequency from an external RF or hydrogen frequency standard. For the convenience of users, apart from the keypad, they can also exercise control of the functions of the devices with a mouse-type manipulator included in the delivery package. Comparators provide access to measurement data over an Ethernet network.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
conductometer MARK® 1102
conductometer MARK® 1102
Measurement of specific electrical conductivity (UEP, UEP25) and mass fraction (C) of solutes (NaCl, NaOH, HNO3, H2SO4, HCl) in water. Control of water-chemical regimes at thermal and nuclear power facilities.Contactless inductive sensor resistant to aggressive environments | Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. The possibility of placing the converter unit at a remote distance from the sampling point | Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. Programmable setpoints with "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings. Submersible, trunk, flow fittings |
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Rubidium frequency and time standards H1-1011
Rubidium frequency and time standards H1-1011
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The composition of the standards H1-1011 and H1-1011/2 includes: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-2010
MARK-2010
Portable device for periodic measurement of the volume fraction of oxygen in various gases (hydrogen, natural gas, nitrogen, argon, helium, etc.). Mainly used for monitoring oxygen in the cooling circuit of generators, electrolysis plants, gas pipelines of boilers, monitoring the air of the working area. The warranty is 24 months for deliveries across the Russian Federation. High-precision measurement of oxygen microconcentrations Unique, patent-protected sensor design Exceptional selectivity to oxygen molecules Insensitivity to humidity, carbon dioxide, oil vapor Stable operation in a gas environment of any composition Ease of operation Automatic temperature and barocompensation The duration of measurements is 2-3 minutes Atmospheric air calibration Routine maintenance - no more than 1 time per year Built-in flow stimulator for forced sample delivery High contrast LED indicator IP54 housing case Protection from dust and moisture Built-in long-lasting battery At least 1000 charge/discharge cycles Carrying strap
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod