Search

119 products
View:
  • Selected: 0
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 11
    Areas of use
  • 38
    Item names
    Loading...
  • 3
    Manufacturer
  • Made in
  • 10
    Additional
View:
119 products
Oxygen meter MARK® 303 M
Oxygen meter MARK® 303 M
Measurement of dissolved oxygen concentration (CRC) and temperature of aqueous media. Laboratory and "field" measurements. Definition of BOD. The sensor is designed specifically for BOD measurement according to the PNF F method 14.1:2:3:4.123-97. 24-month warranty for deliveries across the Russian Federation Convenience and accuracy of measurement | Automatic temperature and barocompensation. Automatic air oxygen calibration. IP65 | Compact sealed device is reliably protected from dust and moisture. Electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Easy calibration by air | Minimum maintenance | Replacement of the membrane no more than once a year. Storage of the sensor in the air. Long-lasting sensor | Sensor service life of at least 10 years.Time to failure - 40,000 hours Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "field" measurements | Measurement of the KRK at a depth of up to 20 meters. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Optical pumping source rubidium D=10mm
Optical pumping source rubidium D=10mm
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 409 A
Oxygen meter MARK® 409 A
Continuous measurement of dissolved oxygen concentration and temperature of aqueous media with excessive hydrostatic pressure.Two independent measurement channels Freely programmable measurement ranges Stability of operation with changes in hydrostatic pressure Permissible short-term (up to 5 min) pressure overload (water hammer) up to 40 MPa High reaction speed. The time to establish the analyzer readings is 2 minutes. Easy and quick replacement of the membrane The sensor is not afraid of "drying out" The content of dissolved hydrogen in the analyzed medium is taken into account The grading interval is 1 month The verification interval is 24 months
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow
Rubidium frequency and time standards H1-1011
Rubidium frequency and time standards H1-1011
The modular construction principle makes it easy to adapt the devices to the specific requirements of the consumer. The standards are available in four versions – H1-1011, H1-1011/1, H1-1011/2 and H1-1011/3, which differ in metrological characteristics and a set of installed devices (modules). The built-in diagnostic system allows you to quickly determine the operability and condition of the main devices of the standards. On the front panel of the devices H1-1011 and H1-1011/2 there is an LCD display and a control panel, with which you can quickly receive information about the current parameters of the devices included in the devices and adjust the frequency of the output signals. The H1-1011 and H1-1011/2 standards can receive chronometric information from GLONASS and GPS satellite radio navigation systems and use it to synchronize the local time scale and automatically adjust the actual frequency value of the built-in highly stable rubidium frequency standard. The composition of the standards H1-1011 and H1-1011/2 includes: rubidium frequency standard H1-1014; MPR-01 satellite radio navigation systems receiver module; amplifier module for highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request). The scope of delivery (at the request of the customer) includes an antenna for the SRNS receiver as part of: antenna unit; mounting device; antenna cable (maximum length 60 m). The H1-1011/1 and H1-1011/3 standards include: the rubidium frequency standard H1-1013; two modules of amplifiers of highly stable sinusoidal signals (at the customer's choice): MUS-01 (3 independent outputs 10 MHz, connector type SR-50-73FV); MUS-02 (3 independent outputs of 5 MHz, connector type SR-50-73FV); MUS-03 (3 independent outputs of 1, 5 and 10 MHz, connector type SR-50-73FV); MUS-04 (6 independent outputs of 1, 5 and 10 MHz in any combination at the customer's choice, SMA connector type); MS synthesizer module with software (SMA connector type) instead of an amplifier module (at the customer's request).
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
hydrogen meter MARK® 509 A
hydrogen meter MARK® 509 A
Continuous measurements of dissolved hydrogen concentration and temperature of aqueous media with excess hydrostatic pressure up to 20 MPa Unique, patent-protected sensor design | Stability of operation with changes in hydrostatic pressure | Permissible short-term (up to 5 minutes) pressure overload (water hammer) – up to 40 MPa | Easy and fast membrane replacement | The sensor is not afraid of "drying" | The calibration interval is 6 months | Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Rubidium frequency standard H1-1022
Rubidium frequency standard H1-1022
Rubidium frequency standards H1-1022 are available both in the standard version and with various options that have differences in functionality and technical characteristics: option 01 is a device with high short–term stability of the output signal frequency; option 02 – a device with a low-level phase noise in the output signal spectrum; option 03 – the device has a binding module in its composition, which allows automatic correction of the frequency of the output signal according to the signal of the external time scale; option 04 – the device has a synthesizer module in its composition, which allows you to receive a sinusoidal signal of a given frequency at the output of the device in the range from 100 Hz to 100 MHz in steps of the order of 4 × 10-6 Hz; option 05 is a device with an extended range of ambient operating temperatures. Through the built-in RS-232 interface, telemetry information is collected from the device nodes, and commands to change the frequency of the output signal are transmitted. The H1-1022 frequency standards have no domestic analogues in terms of their small dimensions, weight, power consumption and operating time, as well as in terms of their numerous functional capabilities.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 509 hydrogen meter
MARK® 509 hydrogen meter
Measurement of the concentration of dissolved hydrogen (CRV), including "ultra-low", and the temperature of aqueous media. Continuous monitoring of parameters of water-chemical regimes at thermal and nuclear power facilities. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic temperature and barocompensation. Long-lasting, highly stable sensor | The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance | from the sampling point Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod