Search

119 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 11
    Applying
  • 38
    Names
    Loading...
  • 3
    Manufacturer
  • Made in
  • 4
    Additional
View:
119 products
Oxygen meter MARK® 303 T
Oxygen meter MARK® 303 T
Convenience and accuracy of measurement | Automatic temperature and barocompensation, air oxygen calibration. Measurement modes | KRK and temperature. IP65 | Compact sealed device is reliably protected from dust and moisture. Non-volatile electronic notebook | The ability to record up to 500 measurement groups in User-named folders. USB port, software included | The ability to create and manage a data archive on a PC. Graphic indicator with backlight | Indication of readings in a user-friendly format, ease of settings. Long-lasting sensor | Sensor service life of at least 10 years. Low power consumption | Up to 600 hours of continuous operation from a set of AA elements. Designed for "operational" monitoring | "Fast" sensor – the measurement time is no more than 3 minutes. Illumination for work in darkened rooms. Record measurements at the touch of a button. Self-diagnosis | Additional guarantee of correct operation of the device
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-409 Dissolved Oxygen Analyzer
MARK-409 Dissolved Oxygen Analyzer
Measurement of dissolved oxygen concentration and temperature of aqueous media, including deaerated ones. Continuous monitoring of water-chemical regimes at thermal and nuclear power facilities. Two channels Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance Automatic temperature and barocompensation. Automatic air oxygen calibration. Long-lasting sensor The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance from the sampling point Up to 100 meters. Communication with external devices Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port, MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable IP65 aluminum housing The device is reliably protected from dust and moisture. Graphic indicator with backlight Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH Analyzer MARK® 9010
pH Analyzer MARK® 9010
Measurement of the activity of hydrogen ions (pH, pH25) of "ultrapure" waters (including water with a reduced electrical conductivity of 0.055 microns /cm) and alkaline waters containing ammonia or amines. Measurement of electrical conductivity (UEP, UEP25), temperature of aqueous media. Control of water-chemical regimes at energy facilities. A new patented measurement method that does not require calibration. The absence of elements that degrade in "ultrapure" water. Convenience and accuracy of measurement | Automatic thermal compensation. Freely programmable measurement ranges. Measurement of conductivity in the range up to 30 microns/cm. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Relay of "dry" contacts (6 pcs.) with programmable functions. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. A single protective box that combines the secondary converter and the hydraulic part. Intelligent data processing algorithms. 5.7" graphic touchscreen display, 65535 colors, resolution 640*480 pixels.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK® 01 MK
MARK® 01 MK
Cooling, throttling, filtration and regulation of sample flow. Indication of temperature, pressure and flow of the sample. Temperature, pressure and cooling water flow indication (optional). Sample preparation for water-chemical regime monitoring devices at energy facilities. Continuous monitoring of sample parameters and data transmission via digital and current outputs. Maintaining stable sample pressure. Alarm and automatic shut-off of the sample supply in case of violation of the regime. Custom temperature and pressure settings for automatic shut -off of sample supply. Pulse line purge valve. Compact stainless steel panel 350*944 mm. One-way service. Easy-to-clean collapsible heat exchanger.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
pH-metrMARK® 902 / MARK® 902A
pH-metrMARK® 902 / MARK® 902A
Measurement of the activity of hydrogen ions (pH, pH25), EMF and temperature of aqueous media. Control of water-chemical regimes at thermal and nuclear power facilities. pH control of aqueous media in technological processes.Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic thermal compensation. Calibration according to standard buffer solutions with their automatic determination. "Active" sensor unit | The digital communication channel of the sensor with the converter unit is up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Oxygen meter MARK® 409 A
Oxygen meter MARK® 409 A
Continuous measurement of dissolved oxygen concentration and temperature of aqueous media with excessive hydrostatic pressure.Two independent measurement channels Freely programmable measurement ranges Stability of operation with changes in hydrostatic pressure Permissible short-term (up to 5 min) pressure overload (water hammer) up to 40 MPa High reaction speed. The time to establish the analyzer readings is 2 minutes. Easy and quick replacement of the membrane The sensor is not afraid of "drying out" The content of dissolved hydrogen in the analyzed medium is taken into account The grading interval is 1 month The verification interval is 24 months
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod