Search

147 products
View:
  • Selected: 0
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 19
    Areas of use
    Loading...
  • 56
    Item names
    Loading...
  • 7
    Manufacturer
  • Made in
  • 26
    Additional
    Loading...
View:
147 products
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-21
Immitance meter E7-21
Technical specifications: Capacitance (10-13-0.02) F, inductance (10-8–16x103) Gn Resistance (10-3–2x107) ohms Conductivity (10-9-10) Cm Q factor, loss factor 10-3-103 The error is ±0.15% Offset voltage 2±0.2 V Measuring signal levels (0.1±0.02) V and (1±0.2) V Range selection: automatic, manual RS-232C interface Dimensions, weight: 90x265x317 mm, 2 kg Power supply: ~220V, 10 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
INDIVIDUAL DOSIMETERS DKS‑AT3509, DKS‑AT3509A, DKS‑AT3509V, DKS‑AT3509S
Control of individual radiation doses from X-ray and gamma radiation. Together with a reader connected to a PC and specialized application software, they form an effective system for automated control of dose loads on personnel. Silicon Planar Detector Lack of own background Simultaneous measurement of dose loads on internal organs Hp(10) and skin Hp (0.07)
Produced in: Belarus, Minsk
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
DOSIMETERS DKG‑AT2140, DKG‑AT2140A, DKG‑AT2140A/1
A small-sized economical device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. A unique combination of economy, speed and usability Working time without replacing batteries (2 x AA): AT2140 - 5000 hours, AT2140A, A/1 - 10000 hours Search mode USB interface and software for configuring the dosimeter and viewing the measured information (AT2140A/1)
Produced in: Belarus, Minsk
Universal calibrator H4-301/1
Universal calibrator H4-301/1
Technical specifications: Voltage reproduction range Uk 200 mV 0.07 + 0.01 DC: from 50 MV to 600 V, Uk 2 V 0.05 + 0.005 sub-bands (UK) 200 MV; 2; 20; 200; 600 V Uk 20 V 0.05 + 0.005 Basic error, ± (% of U + % of Uk): Uk 200 V 0.07 + 0.01 Uk 600 V 0.1 + 0.02 Voltage reproduction range Uk 200 mV 0.2 + 0.05 AC: from 1 mV to 600 V, sv. 20 to 40 kHz 0.2 + 0.1 sub-bands (Uk) 200 mV; 2; 20; 200; 600 V Uk 2; 20 V 0.15 + 0.02 Basic error, ± (% of U + % of Uk): from 20 Hz to 20 kHz 0.15 + 0.02 Uk 200 V; 600 V: 0.2 + 0.05 from 40 Hz to 1 kHz 0.2 + 0.05 DC power reproduction range: from 1 Ma to 200 mA, sub-bands (Ic) 200 Ma; 2; 20; 200 mA Ic 200 Ma 0.1 + 0.02 Basic error, ± (% of I + % of Ic): Ic 2; 20; 200mA 0.1 + 0.01 Power reproduction range AC: from 10 Ma to 200 mA, sub-ranges (Ic) 200 Ma; 2; 20; 200 mA 0.15 + 0.05 Frequency range from 20 Hz to 1 k Hz Basic error, ± (% of I + % of Ic): USB interface Operating temperature range from minus 10 to +50 C Dimensions; weight 428×327×235× mm; 10 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
 INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
INDIVIDUAL DOSIMETERS DKG‑AT2503V, DKG‑AT2503V/1, DKG‑AT2503V/2
Control of individual radiation doses from X-ray and gamma radiation. Together with the reader and software, they form an effective system for automated control of dose loads on personnel. ▪ Simultaneous measurement of the power of the individual dose equivalent and the dose of gamma radiation ▪ Automatic compensation of the detector's own background ▪ The mode of signaling the presence of pulsed radiation with a duration of 10 ns (optional)
Produced in: Belarus, Minsk
SPECTROMETRIC RADIATION MONITORING SYSTEM
SPECTROMETRIC RADIATION MONITORING SYSTEM
Displaying the spectra and dose rates measured by each detection unit (DB) on the object plan or terrain map Identification of the radionuclide composition of the source The possibility of expanding the energy range up to 5 MeV Sealed DB design (IP68) Backup power supply
Produced in: Belarus, Minsk
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
Rapid assessment of surface contamination with alpha-active radionuclides, in particular, polonium-210. The device is easy to operate, suitable for use by personnel of any qualification, including at home. ▪ Scintillation detector ▪ Silicon photoelectronic multiplier ▪ High sensitivity ▪ Light and sound indication when registering alpha particles ▪ Long-term operation without recharging ▪ 1" OLED colour screen
Produced in: Belarus, Minsk
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
DOSIMETER‑RADIOMETER MKS‑AT1117M (WITH HERMETIC CONTAINERS FOR DETECTION UNITS)
Measurement of the ambient dose equivalent or absorbed dose rate of gamma radiation in liquid media, wells, underground storage facilities and other hard-to-reach places Compatible with detection units: BDKG-01, BDKG-03, BDKG-04, BDKG-05, BDKG-17, BDKG-24, BDKG-30 Measurement at depths up to 30 meters Marking on the cable to determine the depth of immersion A Cable Winding Coil
Produced in: Belarus, Minsk
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
X‑RAY CALIBRATION INSTALLATIONS UPR‑AT300, UPR‑AT300/1, UPR-AT300/2
Storage and transfer of kerma units in the air, ambient, individual and directional dose equivalents and their X-ray radiation capacities to working standards and measuring instruments. ▪ The use of highly stable ISOVOLT X-ray machines with metal-ceramic tubes ▪ Field shaper with radiation qualities according to GOST 8.087, ISO 4037, IEC 61267, etc. ▪ Replaceable discs with 11 filter slots; 3 replaceable diaphragms ▪ Additional filters up to 50 mm thick ▪ A protective flap made of tungsten with beam attenuation of more than 1000 times and a response time of less than 0.1 s ▪ A camera monitor and an electrometric unit provide monitoring of the presence and stability of the radiation output ▪ A positioning system in the radiation beam along three axes ▪ A laser detector centering devices ▪ A video surveillance system of indications ▪ Alarm and blocking systems, radiation monitoring ▪ A control system using operator panels and PC
Produced in: Belarus, Minsk
Universal calibrator H4-201
Universal calibrator H4-201
Technical specifications: reproduction of DC voltage from 50 mv to 1000 V - ranges of 200 mV; 2; 20; 200; 1000 V - error 0.01 – 0.023 % reproduction of the sinusoidal AC voltage from 0.3 mV to 750 V - ranges of 200 mV; 2; 20; 200; 750 V - error 0.15 – 0.225 % - frequency range 20 Hz - 100 kHz (20 Hz - 5 kHz on the range. 200 V; 20 Hz - 2.5 kHz on the range. 750 V) reproduction of DC power from 0.03 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.012 – 0.022 % reproduction of AC power of sinusoidal shape from 3 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.062 – 0.23 % - frequency range 20 - 5000 Hz (45 - 1000 Hz on the range. 50 A) RS-232C interfaces; USB operating temperature range from + 5 to +40oC dimensions 184.5x465x540.5 mm weight 20 kg power supply ~ 230 V
MNIPI
Minsk
Produced in: Belarus, Minsk