HYDROGEN GENERATORS (75 L)
HYDROGEN GENERATORS (75 L)
These generators are designed to supply hydrogen to flame chromatographic detectors. The produced hydrogen meets the requirements of GOST 3022-80. Technical specifications for GV-75 iGV-75-O: Productivity H2, l/h 0-75 0-75 O2 capacity, l/h - 37 Maximum output pressure, atm 2 2 Hydrogen pressure stability, not worse, atm 0.0025 0.0025 Hydrogen water content, not more than, ppm 5 5 Purity of hydrogen, % 99.995 99.995 Time to enter the mode, min 30 30 Water consumption, g/l H2 1.0 1.0 Working time without refilling water, hour 4 4 Tank volume O2, l 2.5 2.5 The volume of water to be added to the O2 tank when the "Top up water" alarm is triggered is no more than 1,4 1,4 liters Power consumption, max, VA 800 800 Overall dimensions (width×depth×height), not more than, mm 260×438×550 260×438×550 Weight, not more than, kg 25 26
Produced in: Yoshkar-Ola, Mari El
LABORATORY INSTALLATION OF SELECTIVE HYDROGENATION
LABORATORY INSTALLATION OF SELECTIVE HYDROGENATION
The bench laboratory unit is designed to test the adsorption properties of silica gels, protective layers and selective hydrogenation catalysts. Ambient temperature from +10 to +35C; The relative humidity of the air is not more than 80% at a temperature of 25C;. Power supply – three- or single-phase AC network with a voltage of 220 V ± 10% with a frequency of 50 Hz.; air 0.4 — 0.8 Mpa. The average service life of the installation is 5 years. TECHNICAL CHARACTERISTICS Operating pressure range, MPa 0÷6 Reactor operating temperature range, 0C 20÷600 Reactor inner diameter, mm 20 Internal length of the reactor, mm 690 A thermocouple pocket with a movable filter and a support grid fixed on it to regulate the volume of the tested catalyst. Length of the isothermal zone, mm 300 The type of furnace is Casement Number of thermostatically controlled independent zones 4 The power consumed by each of the four independent thermostatic zones, W ≤ 400 The discreteness of the temperature setting, 0C 0.1 Flow range C2 H4, l/min 0,02÷1,7 Flow range C3 H6, l/min 0,02÷1,7 Flow range H2, l/min 0÷0.02 Flow range N2, ml/min 0.02÷1.7 Actuation pressure of mechanical safety valves, 6,8 MPa Supply voltage 220V 50Hz Power consumption not more than, kW 5 The discreteness of the temperatures and flow rates displayed on the displays is 0.01 Installation weight, kg 230 Overall dimensions of the installation, mm 1680x1480x580 Length of supply gas pipelines, m 20
Produced in: Yoshkar-Ola, Mari El
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
GAS TESTER (PRESSURE, FLOW, TIGHTNESS)
Designed to control the pressure and flow rate of non-aggressive gases in the lines of chromatographic and other analytical equipment. The measurement of gas flow is based on the conversion of the mass flow rate of gas into an electrical signal by the calorimetric method. The measured gas flow and pressure are displayed on a digital indicator. The device has an external RS485 interface, operating under the MODBUS RTU protocol. technical specifications: - gas flow measurement range – from 1 to 750 ml/min; - pressure measurement range from 0 to 0.4 MPa; - gas flow measurement error – no more than ± 2% in the measurement range of 100 art. ml / min; no more than 3% in the measurement range of 100 ... 750 art. ml / min; - measurement error suppression – no more than ± 0.25 %; - measured gases: Air, Nitrogen, Hydrogen, Helium, Argon, Methane; - the presence of a function for monitoring the volume of pumped gas for a given period of time; - the presence of a function for monitoring changes in gas pressure for a given period of time;- the device is powered from an external power source + 15V (an adapter for operation from a 220V 50Hz network is included in the delivery package).
Produced in: Yoshkar-Ola, Mari El
REMEZA TYPE AIR COMPRESSOR
REMEZA TYPE AIR COMPRESSOR
Household oil—free piston compressor - designed specifically for non-professional users. Technical specifications: Capacity, l/min 70 Pressure, atm 8 Engine power, kW 0.75 Receiver volume, l 24 Noise level, 63 dB Weight, kg 32 Overall dimensions (length×depth×height), mm 475×465×645 Single-phase mains voltage 220 V, 50 Hz
Produced in: Yoshkar-Ola, Mari El
THERMAL DESORBER TDS-2
THERMAL DESORBER TDS-2
TDS-2 is a syringe (see Fig. 1), which is installed on the evaporator of the chromatograph. The device is equipped with a crane that cuts off the carrier gas line when removing the rod with the sorption tube from the thermal desorber. When the tap is open, the stem is lowered to the lower position and the sorption tube is inserted into the evaporator brought to the desired temperature. In the conditions of the upper position of the rod, it is also possible to displace air by purging the sorption tube with a carrier gas. Technical characteristics of TDS-2 The heating time to the desorption temperature is no more than 1 sec. The cooling time when moving to a cold zone is no more than 10 seconds. Outer diameter 5-0.1 mm Dimensions of the sorbent chamber: diameter 3.4+0.3 mm length 52 mm (470 µl) Volume (for solid samples) 90 µl Operating temperature ranges* from 50° to 400 °C Overall dimensions (height with the rod fully extended) 320 mm. Weight 0.325 kg.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El
LABORATORY CATALYTIC PLANTS FOR PETROCHEMICALS
LABORATORY CATALYTIC PLANTS FOR PETROCHEMICALS
Catalytic reforming is used to produce high-octane components of automobile gasoline, flavored concentrate for the production of individual aromatic hydrocarbons, as well as technical water. Isomerization of paraffin hydrocarbons is used to increase the octane number of C5 - C6 oil fractions by converting paraffins of normal structure into their isomers having a higher octane number.oroda. Hydrotreating of distillates is used to improve the quality and stability of light distillates, raw materials of catalytic cracking, as a result of the use of reactions of destructive hydrogenation of organosulfur compounds and hydrogenation of unsaturated hydrocarbons. Catalytic cracking is used to obtain additional amounts of light petroleum products, namely high-octane gasoline and diesel fuel, by decomposition of heavy oil fractions in the presence of a catalyst. Alkylation of isobutane with olefins is used to produce gasoline fractions with high stability and detonation resistance using the reaction of interaction of isobutane with olefins in the presence of a catalyst. Polymerization (oligomerization) of olefins is used to produce low molecular weight polymers (oligomers) of propylene and butylene used as motor fuel or raw materials for petrochemical synthesis. Hydrocracking is used to obtain an additional amount of light petroleum products by catalytic decomposition of heavy raw materials in the presence of hydrogen. Thermal cracking and Visbreaking is used to obtain in the mode of thermal cracking – additional amounts of light petroleum products by thermal decomposition of residues from oil distillation, in the mode of visbreaking – improving the quality of boiler fuel Coking is used to produce petroleum coke and an additional amount of light petroleum products from heavy residues. The raw materials are tar, thermal cracking residue, heavy gas oil. The products are, for example, petroleum coke.
Produced in: Yoshkar-Ola, Mari El
CRYSTAL-2000 CHROMATOGRAPH
CRYSTAL-2000 CHROMATOGRAPH
Technical characteristics: DETECTOR - TYPE OF CHROMATOGRAPH - DETECTION LIMIT, G/S (G/ML) -STANDARD DEVIATION, % - LEVEL OF FLUCTUATIONAL NOISES, A (V) -DRIFT, А/H (V/H) FID Crystall-2000 5×10⁻¹² 2 2×10⁻¹⁴ 4×10 ⁻¹³ TCD Crystall-2000 (5×10⁻⁹) 2 (2×10⁻⁷) (2×10⁻⁵) ADC Crystall-2000 5×10⁻¹⁴ 4 1×10⁻¹² 8×10⁻¹¹ FPD-Р Crystall-2000 2×10⁻¹² 6 2×10⁻¹¹ 4×10⁻¹⁰ FPD-S Crystall-2000 2×10⁻¹¹ 10 2×10⁻¹¹ 4×10⁻¹⁰
Produced in: Yoshkar-Ola, Mari El
WATER PURIFICATION DEVICES: SPECTRUM DEIONIZER
WATER PURIFICATION DEVICES: SPECTRUM DEIONIZER
The Spectrum deionizer makes it possible to obtain high–purity deionized water with a specific electrical conductivity of 0.06 - 0.1 mcm/cm and does not require connection to a municipal water supply line. Technical specifications The volume of water poured into the tank is 1.6 liters The specific electrical conductivity of the resulting water is 0.06 – 0.1 mcm/cm Water capacity of at least 6 liters/hour Filter life 700 liters
Produced in: Yoshkar-Ola, Mari El
SPEAKER SWITCHING DEVICES
SPEAKER SWITCHING DEVICES
To switch the nozzle columns, conventional taps (reverse purge, 6-, 8- and 10-port) are used, which, however, are not suitable for switching capillary columns. An alternative way to switch capillary columns is to change the flows in the capillary columns, which is produced by the so-called "Dins switches" (PD). TECHNICAL CHARACTERISTICS of PD The switching time setting range is from 0.1 to 999 min. Switching time is 0.1 s. The dead volume of the crane is less than 1 µl. The temperature of the tap is no more than 350 °C. The pressure in the crane line is not more than 0.4 MPa. Electric power supply — 5 V.
Produced in: Yoshkar-Ola, Mari El
PYROLYSIS INSTALLATION. ISM code.413224.026
PYROLYSIS INSTALLATION. ISM code.413224.026
The unit is designed to simulate and study pyrolysis processes occurring at elevated temperature and pressure in a stainless steel reactor made in the form of a flask. The installation allows you to obtain experimental data, select and optimize the parameters of the technological process, test various variants of raw mixtures, determine the material balance of the process, the characteristics of the process products. technical specifications Operating pressure range, MPa 0÷2 Operating temperature range of the bulb thermostat, 0C 50÷650 Operating temperature range of the pyrolyzer, 0C ± 0.05 The discreteness of the temperature setting, 0C 1 Relative error of temperature maintenance, 0C. ± 0.2 Reactor material steel 12x18N10T Power consumption, kW not more than 3.5 Overall dimensions (HxWxD) 1600x900x580 Weight, kg 100 Continuous operation mode
Produced in: Yoshkar-Ola, Mari El
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El