Search

156 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
All filters
  • 1
    Applying
  • 10
    Names
  • 1
    Manufacturer
  • Made in
  • 1
    Additional
View:
156 products
NVR-0,1D Plate-rotary vacuum pump
NVR-0,1D Plate-rotary vacuum pump
Pumping out steam-gas mixtures is allowed only when the gas-ballast device is open. The NVR-0,1D vacuum plate-rotary pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-021-00218526-2001, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 53390-2009.
Produced in: Kazan
LI-500 Integrated Vacuum Trap
LI-500 Integrated Vacuum Trap
The integrated flanged trap LI-500 is installed inside the diffusion pump instead of the standard oil reflector, without increasing the overall dimensions of the diffusion pump. The LI-500 trap performs the function of an oil reflector, is installed instead of a standard oil reflector in pumps, has an additional number of cooled screens for capturing oil return flow vapors (more than that of the MU trap), covers the entire area of the input high-vacuum flange.
Produced in: Kazan
3VVN1-12M Water ring vacuum pump
3VVN1-12M Water ring vacuum pump
The working fluid of the pump is water. The use of the 3VVN1-12M(H) pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the engine and destruction of the pump's working parts. The 3VVN1-12M(H) water ring vacuum pump is not intended for use in fire and explosion hazardous industries. The 3VVN1-12M(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-053-00218526-2013, designed and manufactured taking into account the requirements of GOST R 52615-2006.
Produced in: Kazan
ND-250 High-vacuum diffusion pump
ND-250 High-vacuum diffusion pump
The working condition of the ND-250(P) diffusion pump depends on the temperature of the working fluid in the pump boiler. During the initial filling, it is recommended to fill the maximum volume of the working fluid. Working fluid is "VACMA OIL 500" vacuum oil (under technical specifications TU 19.20.29-061-00218526-2019). The total amount of working fluid in the ND-250(R) diffusion pump is a maximum of 1.8 liters, a minimum of 1.3 liters. The viewing window for visual inspection of the working fluid has labels of its maximum and minimum amounts. During normal operation of the pump, the level of the working fluid almost does not change. The temperature of the working fluid when the pump is operating at the maximum residual pressure is about 240°C to 255°C. It is recommended to monitor the operation of heaters in the ND-250(R) diffusion pump using the same temperature sensor. The temperature sensor must be installed in a special radiator socket above the heater. If there is a loss of working fluid and an increase in the temperature of the radiators of the pump up to 320˚C, the temperature sensor must give the command to automatically turn off the heaters. The subsequent activation of the pump heaters should not be automatic and should be performed only after cooling the system. Water at the inlet to the cooling systems of the housing and the oil reflector must be supplied with a pressure of 0.3 MPa (3 kgf/cm2) to 0.5 MPa (5 kgf/cm2) and a temperature of plus 4°C to plus 25°C. The recommended cooling water consumption for the housing is 160 l/h, for the oil reflector it is 20 l / h. It is regulated by the outlet water temperature, which should not exceed plus 40°C. The water drain should be free (with a jet break).
Produced in: Kazan
LP-800 Flow Vacuum Trap
LP-800 Flow Vacuum Trap
The LP-800 flow-through water trap is installed on the inlet flange of the diffusion pump and is designed to reduce the flow of working fluid vapors into the pumped volume by condensing them on the cooled elements of the freezing device.
Produced in: Kazan
2NVR-5DM1 Rotary vane vacuum pump
2NVR-5DM1 Rotary vane vacuum pump
The 2NVR-5DM1 rotary vane vacuum pump is manufactured in the climatic version of UHL 4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, but to be used at ambient temperature and pumped medium 283 K to 308 K (+10˚C to +35˚C). It meets the requirements of technical specifications TU 3648-006-00218526-2002. It is designed and manufactured taking into account the requirements of GOST R 52615-2006. Electricity grid must meet the requrimemnts of GOST 32144-2013
Produced in: Kazan
AVDM-100 High-vacuum Diffusion Unit
AVDM-100 High-vacuum Diffusion Unit
The AVDM-100 high-vacuum unit consists of a vacuum diffusion oil-vapor pump, a nitrogen trap, a vacuum gate, a frame or a plate. The principle of operation of the AVDM-100 unit is based on the pumping action of a vacuum diffusion steam oil pump. When the AVDM-100 unit is operating, liquid nitrogen is poured into the trap. Condensation of working fluid vapors occurs on the elements of the freezing device cooled with liquid nitrogen. The frame (plate) is designed for mounting the components of the unit. The ends of the wiring wires are connected to the connector fixed on the plate of the AVDM-100 unit.
Produced in: Kazan
LAP-400P Nitrogen Flow Vacuum Trap
LAP-400P Nitrogen Flow Vacuum Trap
The nitrogen flow trap LAP-400P is designed to protect vacuum pumps from contamination in the form of vapors of resins, oils and adhesives by freezing them on cooled surfaces with the possibility of their removal, and to prevent the penetration of vapors of working fluids of vacuum pumps into the pumped vessel.
Produced in: Kazan
O-ring seal with support ring
O-ring seal with support ring
ConFlat (CF) standard connections are used to ensure the connection of components of vacuum systems operating in the field of high and ultra-high vacuum.
Produced in: Kazan