PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
PEDESTRIAN RADIATION MONITORS (SRK‑AT2327)
Detection of gamma and neutron radiation sources in the flow of pedestrians crossing the border of the controlled object. Rapid adaptation to changes in the radiation background Audible and light alarms The possibility to create a network of MCI (up to 32) under the control of a PC and specialized software High reliability and self-control Backup power supply At the request of the user, the MCI can be supplied without a neutron channel.
Produced in: Belarus, Minsk
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test installations UPU-21, UPU-21/2
High-voltage test installations UPU-21, UPU-21/2
Technical specifications: Output constant voltage, 0 - 3 kV; 0 - 10 kV Output AC voltage, 0 - 3 kV; 0 - 10 kV Measurement of leakage current, from 0 to 100 Ma The amplitude value of the output voltage ripples relative to the set voltage at a load current of 1 mA, ≤ 5% The error of setting the output voltage, ≤ 4% Protection tripping current, up to 50 mA Output power, 500W Overall dimensions (HxWxD), 280x480x475 mm Weight, 36 kg Operating conditions , Operating temperature, from +5 to + 40 °C Humidity, 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
SRK‑AT2327 ALARM METER WITH INFORMATION BOARD
Logging data on dose rate levels and exceeding threshold levels The possibility of placing the detection unit and the temperature sensor at a distance of up to 1 km separately from the scoreboard Additional protection from direct exposure to precipitation
Produced in: Belarus, Minsk
Voltmeters V7-65, V7-65/1, V7-65/2
Voltmeters V7-65, V7-65/1, V7-65/2
Technical specifications: Measuring range 20 mv-1000 V Measurement error ± (0.03% +5 E.M.R.) AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.3% +200 E.M.R. - 4% +800 E.M.R.) Frequency range 20 Hz-100 kHz Direct current Measuring range 1 mA - 2 A Measurement error ± (0.12% +10 E.M.R.) Alternating current Measuring range 10 mA - 2 A Measurement error ± (0.6% +300 E.M.R.) Frequency range 20 Hz - 5 kHz
MNIPI
Minsk
Produced in: Belarus, Minsk
MOBILE RADIATION SCANNING COMPLEX ISS‑AT6103
MOBILE RADIATION SCANNING COMPLEX ISS‑AT6103
Combination of the composition of detection units at the customer's request Scalability of the complex in terms of sensitivity to gamma and neutron radiation in wide ranges Automatic simultaneous gamma-neutron radiation scanning Displaying measurement results with reference to the terrain (GPS) in real time Search and detection of sources of radioactive radiation and identification of isotopic composition Placement and use in impact-resistant cases Assessment of the surface density of 137Cs radionuclide contamination (kBq/m2, Ci/km2)
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT6130S
DOSIMETER‑RADIOMETER ISS‑AT6130S
A small-sized device for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation. The case is made of impact-resistant ABS plastic Convenient menu Search mode
Produced in: Belarus, Minsk
Water bath WB-4K
Water bath WB-4K
WB series baths can be used for sample evaporation, incubation, defrosting, conduction of chemical reactions. Temperature setting range, oC +35...+95 Temperature error, oC ±1.0 Protection against temperature exceeding RAINBOW TSR-150S F-C hydraulic thermostat Supply voltage, V 230+-10% Current consumption 3.3 A Power consumption, W 750 Overall dimensions L х W х H, mm 380 x 325 x 260 Bath dimensions L x W x H, mm 290 x 300 x 205 Total / engine capacity, 17.6/14.6 l
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
DOSIMETER‑RADIOMETER ISS‑AT1117M (STATIONARY‑PORTABLE DOSIMETRIC CONTROL POSTS)
High sensitivity Audible, light and visual alarm of exceeding the set threshold levels The possibility of using both stationary and wearable versions Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4
Produced in: Belarus, Minsk
SPECTROMETER MCG‑AT1321
SPECTROMETER MCG‑AT1321
- Search and detection of gamma radiation sources with identification of radionuclide composition - Measurement of the ambient dose equivalent of gamma radiation The combination of compactness and high sensitivity The possibility to analyze the spectrum and identify radionuclides without using a PC A built-in GPS module Audiable, light and vibration alarms
Produced in: Belarus, Minsk
Signal generator of a special form G6-49
Signal generator of a special form G6-49
General characteristics: USB 2.0 interface, SCPI support Power supply ~ 230 V, 35 V*A Operating temperature range from minus 10 C to + 40 C Dimensions; weight 325×270×125× mm; 4 kg
MNIPI
Minsk
Produced in: Belarus, Minsk