Search

149 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 1
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • 19
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 7
    Manufacturer
  • Made in
  • 24
    Additional
    Loading...
View:
149 products
Measuring antenna P6-23M
Measuring antenna P6-23M
Technical specifications: Frequency range (0.85 - 17.44 GHz) Standing Wave Coefficient (SWR) < 1.7 Effective area at least in the frequency range - from 0.85 to 15 GHz > 150 cm2 - from 15 to 17.44 GHz > 110 cm2 The margin of error of the effective area in the frequency range, no more - from 0.85 to 8.5 GHz ± 20% - from 8.5 to 17.44 GHz ± 15% Orthogonal polarization signal level -25 dB The level of the side lobes, no more than -10 dB Ambient temperature -50°C - 50°C Gabbar dimensions (HxWxD) 887x351x265 mm Weight 6,8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
MOBILE RADIATION SCANNING COMPLEX ISS‑AT6103
MOBILE RADIATION SCANNING COMPLEX ISS‑AT6103
Combination of the composition of detection units at the customer's request Scalability of the complex in terms of sensitivity to gamma and neutron radiation in wide ranges Automatic simultaneous gamma-neutron radiation scanning Displaying measurement results with reference to the terrain (GPS) in real time Search and detection of sources of radioactive radiation and identification of isotopic composition Placement and use in impact-resistant cases Assessment of the surface density of 137Cs radionuclide contamination (kBq/m2, Ci/km2)
Produced in: Belarus, Minsk
POWDIX 600 X-ray powder diffractometer
POWDIX 600 X-ray powder diffractometer
A feature of the POWDIX 600 X-ray diffractometer scheme is the vertical Bragg-Brentano optical scheme with a fixed horizontal sample position, which makes working with powdery materials, gels and other viscous substances more practical and convenient. The high detector resolution and precise positioning of the POWDIX 600 X-ray goniometer achieve an accuracy better than +/- 0.02° (2θ) over the entire angular range. In the POWDIX 600 diffractometer, the X-ray tube is cooled by an integrated closed water circuit, which can be serviced by any laboratory employee. A wide variety of sample holders (holder for massive samples, holder with rotation, phoneless cuvettes) expands the functionality of the POWDIX 600 and makes it an invaluable tool for scientific research in solid-state physics, materials science, chemistry, geology and other fields of science The diffractometer is included in the Russian State Register of Measuring Instruments.
Produced in: Belarus, Minsk
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
DOSIMETER‑RADIOMETER MKS‑AT1117M WITH DETECTION UNIT BDKN‑06 AND A SET OF RETARDER SPHERES
The result of determining the energy distribution of the neutron radiation flux density is used to calculate such quantities as: - integral neutron flux density; - the average energy of neutron radiation in the spectrum; - the average neutron radiation energy by dose; - dose equivalent per unit flow density; - dose equivalent; - effective dose. ▪ Methodological support of measurements ▪ It is possible to supply an expanded set of polyethylene retarder spheres with diameters: 3,5”; 4,5”; 5”; 7”; 9”; 9,5”
Produced in: Belarus, Minsk
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
EMERGENCY DOSIMETRIC ALARM DRG‑AT2331
Detection of SCR in all possible range of its characteristics High reliability Self-monitoring of components Backup power supply Recording and storage of measurement results in the non-volatile memory of the device The possibility of integration with external security systems DRG-AT2331 together with SRK-AT2327, personal computer and software "SARK.NET " allows you to form an alarm system for detecting the occurrence of a self-sustaining chain reaction (SAS SCR).
Produced in: Belarus, Minsk
GAMMA‑RADIOMETERS RCG‑AT1320, RCG‑AT1320A, RCG‑AT1320V, RCG‑AT1320S
GAMMA‑RADIOMETERS RCG‑AT1320, RCG‑AT1320A, RCG‑AT1320V, RCG‑AT1320S
Intelligent spectrometric type detection unit AT1320V: The possibility of radiation monitoring of mushrooms and berries in a 10-liter container box in 20 seconds AT1320S: During the measurements, a preliminary analysis of the radionuclide composition of the sample is carried out. The activity is calculated based on the results of identification of radionuclides present in the controlled sample Methodological support of measurements
Produced in: Belarus, Minsk
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
RADIATION TRANSPORT MONITORS (SRK‑AT2327)
RADIATION TRANSPORT MONITORS (SRK‑AT2327)
Modular principle of system construction Automatic correction of threshold levels when the background level of the environment changes High reliability and self-control Backup power supply Automatic data logging The possibility of connecting a video surveillance system
Produced in: Belarus, Minsk
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
DOSIMETERS‑RADIOMETERS ISS‑AT6130, ISS‑AT6130A, ISS‑AT6130D
Small-sized devices for measuring the power of the ambient dose equivalent and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130). Durable metal case Convenient menu Selective measurement of beta and gamma radiation in mixed fields (AT6130) Measurement of dose rate up to 100 mSv/h (AT6130D) Search mode Headphones for working in noisy environments (on request)
Produced in: Belarus, Minsk
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
DOSIMETRIC INSTALLATION OF GAMMA RADIATION UDG‑AT130
Irradiator with a typical collimator Rotary drum magazine sources in tungsten and lead protection Software control of the movement of sources and positioning of the mobile platform An alarm and blocking system, radiation monitoring system to ensure the safety of the installation Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
UPN‑AT140 NEUTRON RADIATION CALIBRATION UNIT
The field of fast and thermal neutrons in a collimated beam Fast neutron field in “open” geometry using a screening cone according to ISO 8529-2 Drum source magazine with polyethylene and concrete protection at a depth of 1 meter Software control of the movement of sources and positioning of the mobile platform An alarm and blocking systems, radiation monitoring Control from the operator panel or computer with verification automation functions
Produced in: Belarus, Minsk