Voltmeter V7-77
Voltmeter V7-77
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± (0.05% +4 E.M.R.) AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± (0.5% +4 E.M.R.) Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 0.1 µA - 10 A Measurement error, ± ( 0.25% +4 E.M.R.)
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-82
Voltmeter V7-82
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± 0.01% AC voltage , Measuring range, 1 mV - 700 V Measurement error, ± 0.4% Frequency range, 20 Hz- 1 MHz Direct current , Measuring range, 0.2 µA - 10 A Measurement error, ± 0.15%
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Generator G6-46
Generator G6-46
Technical specifications: Frequency range, from 0.1 Hz to 1 Frequency range, from 0.1 Hz to 1 MHz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span)Smooth signal attenuation, at least 20 dB Frequency stability in 15 minutes, no more than 0.5% Hz Frequency setting error, ± 1 % Signal amplitude: - at a load of 600 ohms - without load, not less than 5 V (10 V span) not less than 10 V (20 V span) Smooth signal attenuation, at least 20 dB Frequency instability in 15 minutes, no more than 0.5 %
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeters V7-65, V7-65/1, V7-65/2
Voltmeters V7-65, V7-65/1, V7-65/2
Technical specifications: Measuring range 20 mv-1000 V Measurement error ± (0.03% +5 E.M.R.) AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.3% +200 E.M.R. - 4% +800 E.M.R.) Frequency range 20 Hz-100 kHz Direct current Measuring range 1 mA - 2 A Measurement error ± (0.12% +10 E.M.R.) Alternating current Measuring range 10 mA - 2 A Measurement error ± (0.6% +300 E.M.R.) Frequency range 20 Hz - 5 kHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal calibrator H4-201
Universal calibrator H4-201
Technical specifications: reproduction of DC voltage from 50 mv to 1000 V - ranges of 200 mV; 2; 20; 200; 1000 V - error 0.01 – 0.023 % reproduction of the sinusoidal AC voltage from 0.3 mV to 750 V - ranges of 200 mV; 2; 20; 200; 750 V - error 0.15 – 0.225 % - frequency range 20 Hz - 100 kHz (20 Hz - 5 kHz on the range. 200 V; 20 Hz - 2.5 kHz on the range. 750 V) reproduction of DC power from 0.03 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.012 – 0.022 % reproduction of AC power of sinusoidal shape from 3 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.062 – 0.23 % - frequency range 20 - 5000 Hz (45 - 1000 Hz on the range. 50 A) RS-232C interfaces; USB operating temperature range from + 5 to +40oC dimensions 184.5x465x540.5 mm weight 20 kg power supply ~ 230 V
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-132
Low-frequency signal generator G3-132
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 0.1 Hz to 10 MHz Frequency setting error ±0.02% Frequency instability ±0.01% in 15 min Signal amplitude ± 2.5 V at 50 ohm load ±5 V without load Limits of adjustment of the output signal level from 2 mV to 1.85 V (skz) at a load of 50 ohms from 4 mV to 3.75 V (scz) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz relative to 1 kHz ± 2% at frequencies from 10 Hz to 1 MHz ±10% at frequencies from 1 to 10 MHz Harmonic coefficient ± 0.2% at frequencies from 10 to 100 Hz ±0.07% at frequencies from 100 Hz to 20 kHz ± 0.2% at frequencies from 20 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 10 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V In the frequency range from 0.1 Hz to 2 MHz, the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Generators G4-221, G4-221/1
Generators G4-221, G4-221/1
Technical specifications: Frequency range of sinusoidal waveforms, 0.1 Hz - 17 MHz Frequency range of rectangular-shaped signals, 0.1 Hz - 1 MHz Frequency setting discreteness, ±(0.012 + 0.0001 f), f in Hz Frequency instability in 15 minutes, no more than ± 1•10-5 Smooth signal attenuation, 40 dB Stepwise signal attenuation, 20, 40, 60 dB
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-21
Immitance meter E7-21
Technical specifications: Capacitance (10-13-0.02) F, inductance (10-8–16x103) Gn Resistance (10-3–2x107) ohms Conductivity (10-9-10) Cm Q factor, loss factor 10-3-103 The error is ±0.15% Offset voltage 2±0.2 V Measuring signal levels (0.1±0.02) V and (1±0.2) V Range selection: automatic, manual RS-232C interface Dimensions, weight: 90x265x317 mm, 2 kg Power supply: ~220V, 10 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
High-voltage test installations UPU-21, UPU-21/2
High-voltage test installations UPU-21, UPU-21/2
Technical specifications: Output constant voltage, 0 - 3 kV; 0 - 10 kV Output AC voltage, 0 - 3 kV; 0 - 10 kV Measurement of leakage current, from 0 to 100 Ma The amplitude value of the output voltage ripples relative to the set voltage at a load current of 1 mA, ≤ 5% The error of setting the output voltage, ≤ 4% Protection tripping current, up to 50 mA Output power, 500W Overall dimensions (HxWxD), 280x480x475 mm Weight, 36 kg Operating conditions , Operating temperature, from +5 to + 40 °C Humidity, 80% at 25 °C
MNIPI
Minsk
Produced in: Belarus, Minsk