Search

135 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 122
    Names
    Loading...
  • 27
    Manufacturer
    Loading...
  • 16
    Made in
  • 43
    Additional
    Loading...
View:
135 products
Pulsating Discharge Detector(PRD)
Pulsating Discharge Detector(PRD)
It operates in the mode of a helium ionization detector (GID) and is considered the most sensitive device for determining permanent gases. In addition, it is able to work in the EDD mode. Technical characteristic: 2.0*10`13 g/s by. methane or hydrogen
Produced in: Yoshkar-Ola, Mari El
Electronic diaphanoscope YANTAR
Electronic diaphanoscope YANTAR
1 supp.
The principle of operation of the electronic diaphanoscope YANTAR is to assess the vitreousness of the image obtained using a digital camera. The vitreous value is calculated using a software-implemented algorithm using special calibration equations. The analysis time is 1 minute. Automation of the vitreous assessment avoids the error associated with the subjective opinion of a specialist. The use of specially developed calibration standards based on optical filters for uniform adjustment of diaphanoscopes permits to coordinate the operation of two or more devices remotely. The interlaboratory error in determining the vitreousness on the devices included in the network does not exceed the standard. All the results of the determination of the vitreousness of wheat with the corresponding grain images are stored in the archive. If necessary, specialists can print the protocols of the current or any of the previous definitions. THE ALGORITHM OF OPERATION: 1. Pour the grains into the cassette and close the lid made of transparent glass. 2. Install the cassette in the diaphanoscope. 3. Launch the program. 4. Choose a product 5. Software processing of the digital image of grains in accordance with the selected product 6. Calculation of computer results. In 2023, a new national standard GOST R "Wheat. Determination of vitreousness by optical-computer method".
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
REVERSE PURGE VALVE
REVERSE PURGE VALVE
The reverse purge valve is a 4-way valve designed to change the direction of the flow of the eluent through the nozzle column and blow off heavy components from the beginning of the column in the opposite direction into the detector. The crane is attached to the bottom panel (bottom) of the module, while taking the temperature of the column thermostat. The two upper fittings (see Fig.) are used to connect the column, the other two are connected to the evaporator and the detector.
Produced in: Yoshkar-Ola, Mari El
LIQUEFIED GAS METERING VALVE
LIQUEFIED GAS METERING VALVE
The metering valve for the analysis of liquefied gas (KDSG) is designed for the introduction of liquefied gas or other liquid under excessive pressure into the evaporator of the chromatograph. KDSG is a 4-way crane, in which a dose of a certain volume is installed. The tap is installed on the evaporator of the chromatograph. A dose of any volume can be installed on the tap. Dose change can be performed by the operator. The amount of the dose volume is indicated on the tag. Technical specifications The dose volume is from 0.25 to 4.0 µl (at the request of the consumer, the dose volume can be increased up to 10 µl). The tap temperature is no more than 150 °C. The pressure in the crane line is not more than 0.48 MPa. The angle of rotation of the crane handle is 90 °C.
Produced in: Yoshkar-Ola, Mari El
High pressure gas flow regulator RRG-VD
High pressure gas flow regulator RRG-VD
It can be used as a primary source of carrier gas, since it is equipped with an additional gas purification system. This device is especially relevant when, for some reason, helium is not available to the consumer (for example, when working with a thermal conductivity detector - an accident). Due to the high thermal conductivity of hydrogen, TTP operates with significantly greater sensitivity than helium.
Produced in: Yoshkar-Ola, Mari El
Gas chromatograph Crystallux-4000m
Gas chromatograph Crystallux-4000m
The gas chromatograph "Kristallux-4000M" is fully automated, starting from sample input and ending with chromatographic information processing, including the functions of automatic temperature control of thermostats, flow rates and pressure of the carrier gas (EUPG system), auxiliary gases, automatic ignition of detectors, flame burning control during operation, measurement of detector signals using Gorenje 24-bit ADC. Technical specifications: The detection limit of PID is 1,1x10-12 gS/s for h-hydrocarbons 1,1x10-12 gS/s for propane. The detection limit of DTP1.7x10-14 g/s for lindane 3.9x10`15 g/s for lindane (micro-ED) The detection limit of EZD1x10`13 grus for phosphorus in metaphos 8x10`13 g5/s for sulfur in metaphos or hydrogen sulfide PFD detection limit 1.5x10`14 g/s for phosphorus in metaphos 3x10`13 GM/s for nitrogen in azobenzene Detection limit of TID2x10`10 g/ml by hydrogen The detection limit of TcD is 5x10`13 g/s for benzene The detection limit of the FEED is 3x10`13 g/s for carbon in methane 3x10`13 g/s for carbon in methane Detection limit GID500:1 (M7-801) with the introduction of 1x10`12 g / ml of octafluoroaphthalene The signal-to-noise ratio of MSD 1500:1 (Maestro-oMS) when entering 1x10`12 g / ml of octafluoroaphthalene Linear dynamic range of PID x1*107 Linear dynamic range DTP1*108 The volume of the column thermostat is 14 (19)l The temperature of the column Current.Wednesday +3 °C to +400 °C (by special order up to 450 °C) (by special order from -10°C with use. cold. ust-ki)(by special order from -100 °C. with use. liquid, no.) The discreteness of the temperature setting is 0, ° C Temperature stability 0.01 °C Temperature programming speed 0t 0.1 to 125 °C/min (by special order up to 150 °C/min) The number of isotherms is not less than 30 The cooling rate of the column thermostat is from 400 to 50 °C3.3 min. The maximum temperature of the detector and evaporator is 450 °C Carrier gas consumption from 0 to 100 ml/min.(by special order up to 500 ml/min.) Carrier gas pressure (for capillary column) from 0 to 0.40 Mpa (by special order up to 1 MPa) The maximum inlet gas pressure on a special order is 0.5 MPA 1.25 MPA Hydrogen consumption 0-500 Air consumption 0-1000 Overall dimensions (width x depth x height) 550%500*500 mm Weight 39 kg Electric power supply from AC mains voltage (220.2) V, frequency (50 +1) Hz The maximum power consumption (in steady-state mode) is 900 VA.
Produced in: Yoshkar-Ola, Mari El
PYROLYZER
PYROLYZER
The pyrolytic gas chromatography method is widely used in the study of polymer materials, plastics, rubbers, rubbers, paints and other high-molecular compounds of natural and artificial origin. The method is based on thermal decomposition of sample samples in an inert medium (without oxygen access), followed by chromatographic separation and analysis of the formed volatile compounds. Thus, the resulting pyrogram allows us to judge the composition of the original sample. Pyrolysis is also used in geochemical studies. Technical specifications The volume of the capsule is 56 ml. Pyrolysis temperature — from 200 to 1000 °C. The error of maintaining the temperature is not more than 1.0 ° C. The heating time of the sample to the pyrolysis temperature is no more than 2 seconds. The cooling time of the capsule when moving from the hot zone to the cold zone after pyrolysis is no more than 10 seconds. The time of continuous operation in the pyrolysis mode is no more than 60 seconds. Electric power supply from the AC network with voltage (220index) V, frequency (50 ± 1) Hz. Power consumption — no more than 100 VA. Overall dimensions of the control unit (width ×depth×height) — 210×190×100 mm. Overall dimensions of the input node (width× depth×height) — 90×135×160 mm. The weight of the control unit is not more than 2.5 kg. The weight of the input node is not more than 0.9 kg.
Produced in: Yoshkar-Ola, Mari El
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
Compact magnetic stirrer PL-R-atom USB, 2 liters. Primelab
The speed is set in the range from 150 to 2000 rpm, the timer is up to 99 minutes. Country of origin, Russia Orange color Protection class (according to DIN EN60529), IP21 Number of places for mixing, 1 Maximum volume of mixed liquid, 2 l Range of operating speeds of the motor shaft, 150-2000 rpm Connection – external temperature sensor PT1000 (sold separately) Power: USB port. Dimensions, weight Overall dimensions LxWxH, 160x148x48 mm Diameter of the working surface of the plate, 128 mm Device weight, 0.3 kg Contents of delivery Magnetic stirrer without heating PL-R-atom Operating manual combined with passport Anchor for stirrer in fluoroplastic sheath 5x30 mm; DC power supply, output voltage 9V, rated input voltage ~220V, 50Hz. USB cable
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
DISPENSER "EVEN 4000"
DISPENSER "EVEN 4000"
The dispenser "DAZH 4000" is designed for automatic insertion of liquid samples into the evaporator of the gas chromatograph, provides: control from the software, setting variable parameters of algorithms for washing and sample entry, storing the operating parameters of the dispenser in the method. Technical characteristics: The number of vials in the carousel, pcs up to 30 The volume of installed vials, ml 0.1-2ml Number of injections from one vial 1-99 Replaceable syringes in volume, ml 10, 100, 250, 500 The volume of the injected sample, ml : from 0.01 to 500 The discreteness of setting the sample volume, µl: from 0.01 to 1 Sampling and insertion rate, µl/s: from 0.01 to 5000 The speed of needle insertion into the evaporator, discret 3 Immersion depth in the vial and evaporator, variable up to the length of the syringe needle, mm 1 – 99 The discreteness of the dive depth setting, mm 0,1 The number of pumping during sampling 0-15 Number of solvent washes 0-15 Needle exposure time in the evaporator, sec 0-99 The discreteness of setting the needle shutter speed, sec 1,0 Sample input modes Simple insertion, Sandwich, Solvent sandwich, Sandwich with internal standard Flushing mode From the vial Supply voltage, V (frequency, Hz) 220 (50) Power consumption, W 154 Weight, kg, no more 2,9 Overall dimensions, mm 175x270x420 Communication with the computer Ethernet
Produced in: Yoshkar-Ola, Mari El
Thermionic (TID)
Thermionic (TID)
Selective detector for organophosphorus and nitrogen compounds. It is also sensitive to compounds containing C, Az, but to a lesser extent. The sensitivity depends on the number of heteroatoms in the molecule. Selectivity to hydrocarbons is 104 for nitrogen, and 105 for phosphorus Technical characteristic: 2.0*10-13 m/s nitrogen 1.5*10`14 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Whiteness meter BARS
Whiteness meter BARS
1 supp.
The principle of operation is based on measuring the zonal reflection coefficient of a compacted-smoothed flour surface using a built-in standard. The laboratory white meter BARS is approved as a type of measuring instruments and is registered in the State Register of Measuring Instruments under No. 78409-20. All manufactured devices undergo primary verification and have the appropriate certificate. Due to the two-channel design of the device (the presence of two photometric units and a cuvette with two cells), parallel measurements of the whiteness of one flour sample are carried out simultaneously, the average value is calculated automatically, which significantly reduces the time of analysis. The sealing of the flour sample with a fixed force and pressing against the optical windows ensures the same measurement conditions and eliminates the influence of a subjective factor on the result. The automatic adjustment system based on the built-in standard allows to ensure long-term stability of the device without the need for manual adjustment. During operation, the standard is set to the working position by an additional drive. Mechanical damage or loss of the standard is excluded. The output to the operating mode is no more than 30 seconds. The determination of whiteness is carried out in 15 seconds. To determine the whiteness of flour, the operator needs to fill 2 compartments of the cuvette with the test sample of flour, install the cuvette in the device and start the measurement process. All the results of the whiteness definitions are stored in the archive. The operator has the opportunity to view the electronic measurement log.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
AUTOSAMPLER "NT3100A": FUNCTIONS
AUTOSAMPLER "NT3100A": FUNCTIONS
The autosampler is used to automate the process of entering samples of liquid consistency into chromatographs of the line "Kristallux", "Crystal", series "Color", LHM. The autosampler is compact in size and easy to operate. The device is compatible with different models of chromatographs and is suitable for many studies. When the device is working with the Crystallux series chromatographs, the autosampler can be controlled using the chromatographic equipment software, while no additional programs are required.
Produced in: Yoshkar-Ola, Mari El