Monochromators "LM-3" and "LM-4"
Monochromators "LM-3" and "LM-4"
1 supp.
Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Vibration velocity sensors with current output DVST-3
Vibration velocity sensors with current output DVST-3
Vibration velocity sensors with a current output DVST-3 are designed to convert the RMS value of the vibration velocity of an object into a standard current signal of 4-20 mA.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
Model 130 Profilometer
Model 130 Profilometer
Measurement of roughness parameters Ra; Rz; Rmax; Rp; Rv; Rq; Sm; S; la; lq; tp; Lo; D; da; dq, etc., viewing the profilogram and measuring the size of inhomogeneities Tracing length: 0.5mm – 40 mm Measurement range according to Ra: 0.012 – 50mkm Degree of accuracy 1 (error 2%) Work inside the vestibule > 3mm
Produced in: Moscow, Zelenograd
Kepler-10b Vacuum furnace
Kepler-10b Vacuum furnace
Horizontal vacuum resistance furnaces are designed for carrying out various technological processes in high vacuum at temperatures up to 1600 degrees. The furnace can be used in electronic, radio engineering, aviation, rocket and other industries. The main areas of application are the technological processes of annealing, quenching, degassing and sintering.
NPO "Gelikon"
Saint Petersburg
Produced in: Saint Petersburg
IR microscope "MIKRAN"
IR microscope "MIKRAN"
The IR microscope "MIKRAN" is designed to work with IR Fourier spectrometers "Infralum FT-801". The spectral range is 6000 – 600 cm-1 (with a microscope and an MST detector cooled with liquid nitrogen). Resolution 0.5, 1, 2, 4, 8 cm-1 (determined by the resolution of the Fourier spectrometer)
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Piezoelectric vibration measuring transducers DN-3-M1, DN-3-M1 B6
Vibration transducers DN-3-M1 are designed to measure vibration by converting mechanical vibrations into electrical signals proportional to the vibration acceleration of an oscillating object. Vibration converters DN-3-M1 are used in conjunction with vibration measuring devices in factory and laboratory conditions.
VIBROPRIBOR
Yaroslavl
Produced in: Yaroslavl
IR microscope "MIKRAN-3"
IR microscope "MIKRAN-3"
A higher–level device with extreme sensitivity and an additional set of functions that allow you to expand the possibilities for conducting spectral studies: · revolver mechanism with 4 interchangeable lenses - mirror IR 15X, NPVO, lens 4X, lens 10X; · registration of spectra in the modes of specular and diffuse reflection, transmission and NIP; · increased sensitivity, which allows recording the spectra of micro-objects with sizes from 5 microns; · built-in control panel with advanced functions; · automated mapping system; · the rectangular slit diaphragm is made of special glass – after the fragment is selected, the rest of the field of view is also available to the user, which greatly simplifies photometry of extended surfaces with local inhomogeneities; · specialized software for controlling the microscope and processing the results. Liquid nitrogen is required to work with an IR microscope.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
EVRASAMP ESC Sampling with low carbon content
EVRASAMP ESC Sampling with low carbon content
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Type of sampler: Ceramic sampler with an elongated leg Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium