Search

396 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 142
    Item names
    Loading...
  • 37
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • 36
    Additional
    Loading...
View:
396 products
EVRASAMP ESC Sampling with low carbon content
EVRASAMP ESC Sampling with low carbon content
Appointment: Sampling for chemical, spectral, etc. analysis of molten metal Scope of application: Oxygen converters, electric arc furnaces, induction furnaces, vacuum cleaners, steel ladles, filling ladles, etc. Type of sampler: Ceramic sampler with an elongated leg Operating temperature range (depending on the type of sampler): from 1150°C to 2020°C Selection time: from 3 to 5 seconds Tube Length: from 100 to 1500 mm (other lengths are available on request) Slag Cap: Steel, Cardboard, Aluminum Deoxidizer: Without deoxidizer, aluminum, zirconium, titanium
Produced in: Lipetsk
Voltmeters B7-91, B7-91/1
Voltmeters B7-91, B7-91/1
Technical specifications: DC voltage , Measuring range, 10 MV - 1000 V Measurement error, ± 0.03% AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± 0.4% Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 1 mkA - 2 A (B7-91/1) Measuring range, 1 mkA - 20 A (B7-91) Measurement error, ± 0.03%
MNIPI
Minsk
Produced in: Belarus, Minsk
XFP WDM Transceiver
XFP WDM Transceiver
XFP (10-Gigabit Small Form Factor Pluggable) is a protocol—independent hot-swappable optical transceiver, usually operating at 850nm, 1310nm or 1550nm wavelengths or wavelengths from the CWDM band at a speed of 10 gigabits per second in SONET/SDH, Fiber Channel, Gigabit Ethernet, 10 Gigabit Ethernet and other applications, including WDM channels.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Power supply PCS-30-80
Power supply PCS-30-80
Operating Mode: Continuous Output stabilized current, A: 1-80 Output voltage, V: 0-30 Current pulse duration, mks: 50-450 Frequency of repetition of current pulses, Hz: 10-100 Power supply: Single-phase 220 V 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 7 Overall dimensions (W x H x D), mm: 350 x 150 x 350
INZHEKT
Saratov
Produced in: Saratov
Frequency meters H3-96
Frequency meters H3-96
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 3200 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz The number of averages. the period of the input signal is 1 ... 105 Borehole measurement by inputs – 1.000001- 999999999 Frequency ratio in channels: A/S, C/A, B/C and B/A - up to 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 2•10-8 - in 30 days, ± 5•10-8 - in 12 months Overall dimensions (HXHL) - 345x285x106 mm Weight: 4 kg Reference generator: ±5x10-8 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
IR Laser Module KLM-B808-x-5 808nm
IR Laser Module KLM-B808-x-5 808nm
from 19 176 ₽
Laser modules of the KLM-B808-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Green Laser Module LG-D532-x-5 532nm line
Green Laser Module LG-D532-x-5 532nm line
from 11 026 ₽
The generators of the LG-D532-x-5 series are optimal sources of coherent radiation for the construction of control and automation systems, alignment and marking devices, for scientific and medical purposes.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Chassis for MCRC19-14PS2 Media Converters
Chassis for MCRC19-14PS2 Media Converters
from 12 345 ₽
Using the chassis to install converters is an excellent solution for the efficient organization of signal conversion of various standards. For systems mounted in a basic 19" rack, we offer unmanaged chassis of standard size 2U for 14 unmanaged media converters (10/100 Mbit/s) with a slot for integrated power supplies. They support the possibility to install up to 14 converters.
FTI-Optronik
Saint Petersburg
Produced in: Saint Petersburg
Mobile adsorption compressor nitrogen plants and stations
Mobile adsorption compressor nitrogen plants and stations
Provita Company designs and manufactures nitrogen compressor stations based on sea containers (10, 20, 30, 40–feet) and sandwich panel block boxes with standard dimensions and fasteners, which allows them to be transported by road, rail and sea transport. A mobile compressor unit can be carried out on an automobile chassis or on a sled for transportation to remote hard-to-reach regions. The nitrogen compressor station can be supplied in various climatic versions: northern (ambient temperature up to -55°C) standard (from -45 to +45°C) tropical (up to +55°C)
PROVITA
Saint Petersburg
Produced in: Saint Petersburg
Spectrum Analyzer S4-101
Spectrum Analyzer S4-101
Technical specifications: The operating frequency range of the monitored signals is from 9·103 to 3·109 Hz The analyzer has a zero band and a viewing band in the range from 100 Hz to 3 GHz Limits of permissible error of setting the viewing band ± 1 % The scan range is set from 10 ms to 3000 s in all modes except the zero band of view, and from 20 microseconds to 3000 s in the zero band of view mode The bandwidth of the RFP at the level of minus 3 dB is selected in the range from 100 Hz to 1 MHz in increments of 1, 3, 10 The squareness coefficient of the FPC at the level of minus 60 dB / minus 3 dB is not more than 5:1 The reference level setting range is from plus 30 dBm to minus 100 dBm. Installation step 1 dB Limits of the permissible basic error of setting the reference level ± 1 dB The limits of the unevenness of the amplitude-frequency response (frequency response) of the analyzer in the frequency range from 100 kHz to 3 GHz ± 1 dB Maximum allowable input power is 30 dBm (1 W) Limits of the permissible basic error of measuring the signal level due to the nonlinearity of the logarithmic scale ± 1 dB Limits of the permissible basic error of measuring the signal level due to switching of the input attenuator ± 1 dB Limits of error in measuring the signal level due to switching filters, ± 0.2 dB relative to the 1 kHz filter The average level of intrinsic noise at the FPC bandwidth of 100 Hz, the video filter band of 10 Hz and the input attenuator of 0 dB: - in the range from 100 kHz to 20 MHz minus 75 dBm - in the range from 20 MHz to 1.5 GHz minus 110 dBm - in the range from 1.5 to 3 GHz minus 105 dBm The input impedance of the analyzer is 50 ohms The voltage standing wave coefficient (VSWR) of the input with an input attenuator greater than 10 dB, no more: - 1.5 in the frequency range from 10 MHz to 2.5 GHz - 1.8 in the frequency range from 2.5 GHz to 3 GHz Diagonal screen size 21.5 cm Screen resolution 800x480 USB interface Overall dimensions – 398x220x150 mm Weight not more than 6.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk