Immitance meter E7-23
Immitance meter E7-23
Technical specifications: Conductivity (G) - 10-9 – 10 Cm Resistance (R, X, |Z|) - 10-4 – 108 ohms Capacity (S) - 10-14 – 10-1 F Inductance (L) - 10-8 – 104 Gn Q factor (Q), loss angle tangent (tg) 10-3 – 103 Phase angle. shift comp. resistance -180° - +179.9° Leakage current (I) - 10-7 – 10-3 A Measurement error - 0.15 % Operating frequencies – 0.1; 1; 10 kHz (± 0.02%) Measurement levels. signal (SKZ) – 0.04; 1 V The offset voltage on the measured object is 0 – 63 V The output resistance of the source. izmer. signal – 100 ± 20 ohms The time of one measurement is 60, 600 ms, 6 s Power consumption - 20 VA Overall dimensions - 90x265x317 mm Weight - 3.5 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Voltmeter V7-77
Voltmeter V7-77
Technical specifications: DC voltage , Measuring range, 10 mv-1000V Measurement error, ± (0.05% +4 E.M.R.) AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± (0.5% +4 E.M.R.) Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 0.1 µA - 10 A Measurement error, ± ( 0.25% +4 E.M.R.)
MNIPI
Minsk
Produced in: Belarus, Minsk
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency comparator CHK7-51
Frequency comparator CHK7-51
Mathematical processing of the measurement makes it possible to determine and display on the indicator board the relative systematic change in frequency, the average relative value of the frequency difference, the RMS relative frequency deviation, the RMS relative two-sample frequency deviation.
NNPO im. M.V.Frunze
Nizhny Novgorod
Produced in: Nizhny Novgorod
Low-frequency signal generator G3-131A
Low-frequency signal generator G3-131A
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 2 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min Signal amplitude ±5 V at 600 ohm load ±10 V without load Limits for adjusting the output signal level from 1 mV to 3.75 V (scr) at a load of 600 ohms from 2 mV to 7.5 V (scz) without load Signal level unevenness ± 2% at frequencies from 20 Hz to 200 kHz relative to 1 kHz ± 5% at frequencies from 200 kHz to 2 MHz Harmonic coefficient ± 0.3% at frequencies from 2 to 20 Hz ± 0.2% at frequencies from 20 Hz to 100 kHz ±1% at frequencies from 100 kHz to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk