Search

72 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 66
    Names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • 32
    Additional
    Loading...
View:
72 products
Raid bomb BR-02T
Raid bomb BR-02T
It is designed to determine the absolute vapor pressure of crude oil and petroleum products with a saturated vapor pressure over 180 kPa (except for liquefied petroleum gases) in accordance with the State Standard 1756 and the State Standard 31874 (except for method B). The ratio of volumes of air and liquid chambers within 3.95 4.05.
Produced in: Tomsk
Sulfur Analyzer SPECTROSCAN IS, IS-T
Sulfur Analyzer SPECTROSCAN IS, IS-T
The IS-T and IS X-ray absorption flow SPECTROSCAN analyzers for sulfur in oil are designed to determine the mass fraction of sulfur in the flow of oil/petroleum products in the range from 0.02% to 6.00% (IS-T) or 0.04% to 6.0% (IS). Analyzers can be used for technological control during transportation and storage of oil, as well as during mixing (compounding) operations. The design of the analyzers allows them to be placed both independently and as part of a unit for measuring oil quality indicators (BIC) or a system for measuring the quantity and quality of oil (CIC). They are available in explosion-proof version. The analyzers have the function of automatically accounting for the influence of the density of the analyzed medium, as well as the content of water and chloride salts in it on the result of determining the mass fraction of sulfur. Structurally, the analyzers are a complete product of high factory readiness, having a block-modular design and including all the necessary functional devices to ensure efficient and safe operation.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Primelab density measurement setup
Primelab density measurement setup
from 190 000 ₽
The Primelab installation has the following equipment: Three double-walled glass hydrometer cylinders with glass or Teflon stopcocks (available in two versions); Rack with clamps for three cylinders; Glass manifolds for three cylinders – 2 pcs.; PTFE cover for the cylinder – 3 pcs; Silicone tubes 1 meter – 2 pcs. At the bottom of each cylinder there is a tap that allows you to rinse the container from the previous sample without disassembling the installation for a quick transition to the analysis of the next product. It is possible to supply additional cylinders and a circulation thermostat. A liquid thermostat will be selected upon request. The installation equally accurately determines the density of light and dark products, including gasoline, crude oil, diesel fuel, etc. Specifications: Number of cylinders assembled – 3 The height and volume of each cylinder is 350 mm x 750 ml Measurement temperature – from -5 to 100°С Temperature maintenance accuracy - 0.1°C Tripod base size – 300 mm x 300 mm Tripod height – 700 mm The weight of the installation without glass cylinders is 10 kg. Installation benefits The Primelab petroleum product density measurement unit has a number of advantages. Among the main and significant ones are the following: Removable stainless steel tray; All glass elements are made of Simax borosilicate glass; Wide operating temperature range; The hydrometer is visible along the entire length of the glass cylinders; Removable stainless steel tray; PTFE covers; The small size of the installation allows it to be placed in almost any area. Characteristics Country Russia Volume, ml: 750 (each cylinder) Height, mm: 350 (each cylinder) Compliance: GOST 3900-85, ASTM D1298 Accuracy: up to 0.1°C Version: floor, tabletop Temperature measurement range, °C: -5 to +100 Dimensions: base - 300x300 mm, height - 700 mm Device weight, kg: 10 (without cylinders) Unique opportunity: custom manufacturing of a Primelab installation for determining the density of petroleum products to meet specific customer requirements.
Primelab
Mytishchi
Raid Bomb BR-01T
Raid Bomb BR-01T
The ratio of volumes of air and liquid chambers within 3.95 4.05. Overall dimensions 57x400 mm Weight 2 kg
Produced in: Tomsk
The set for cryoscopic determination of the molecular weight of CRYON-1
The set for cryoscopic determination of the molecular weight of CRYON-1
The CRYON-1 unit is ideally suitable for measuring the molecular weight of separated oils by cryoscopy in benzene in accordance with OST 153-39.2-048-2003. • Solvent crystallization temperature range -15...+15 °C Overall dimensions 140x160x300 mm Weight 4 kg Power consumption 50 W
Produced in: Tomsk
NEVA-412 alarm system
NEVA-412 alarm system
1 supp.
Technical specifications: Analog output 0-0.5 V (4-20 mA on request) Overall dimensions 320x255x175 mm Water pressure 0.1-3 atm The door of the alarm opens to the left side Measuring range 0-30 ppm Alarm relay contacts dry contact (power up to 2A/250V) Control relay contacts dry contact (power up to 2A/250V) Linearity +(-)2% in the range of 1-20 ppm Trigger threshold setting from 1 to 30 ppm (in increments of 1 ppm) Connecting dimensions of flanges external thread 1/2" Signal norm green LED Alarm red LED Degree of protection IP X4 The temperature of the controlled environment is +4 ... +55 °C Ambient temperature 0 ... +55 °C Measurement accuracy in accordance with resolution MERS.107(49) CF type flash memory card (software included) at least 32 MB RS485 digital output (on request) Power supply 200/240 V, 50/60 Hz (on request = 24 V) Weight not more than 10.5 kg Power consumption < 6 W
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Chlorine and Sulfur Analyzer SPECTROSCAN CLSW
Chlorine and Sulfur Analyzer SPECTROSCAN CLSW
The device is developed on the basis of the analyzer SPECTROSCAN SW-D3, allows you to determine the mass fraction of organochlorine compounds in oil according to GOST R 52247-2004 (method B) and GOST 33342-2015 (method B), the sulfur content in automotive fuel, oil and liquid petroleum products in accordance with GOST R 52660-2006 / GOST ISO 20884-2016 and GOST R 53203-2008 / GOST 33194-2014, as well as to determine the mass fraction of chlorine and sulfur in any liquid samples in accordance with standardized techniques (methods). Implements arbitration methods for determining the mass fraction of organochlorine compounds in oil and the sulfur content in automobile fuel. The analyzer has successfully passed the interlaboratory tests under the guidance of JSC "VNII NP" (TK31). As a result of the tests, the accuracy of the method for determining the mass fraction of organochlorine compounds using the SPECTROSCAN CLSW analyzer was found to comply with the requirements of GOST R 52247-2004, method B, and the accuracy of the method was determined in the range of the mass fraction of organochlorine compounds from 1 ppm to 50 ppm. Determination of the mass fraction of organochlorine compounds in oil involves sampling of oil, distillation of naphtha fraction (204 ° C), washing of naphtha from hydrogen sulfide and inorganic chlorides. An internal standard is introduced into naphtha extracted from oil – a solution of bismuth in a non-polar solvent and an analysis is carried out. When determining the sulfur content, the analysis is carried out without additional sample preparation. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. There is a conclusion of the Ministry of Industry and Trade on the production of products in the territory of the Russian Federation. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the chlorine and/or sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of an element in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
LAB-KMP kit for testing corrosion activity on a copper plate
LAB-KMP kit for testing corrosion activity on a copper plate
The LAB-KMP kit is designed for testing the corrosion activity of petroleum products in accordance with GOST 6321-92 or ISO 2160. The kit is used in conjunction with LOIP LT thermostats and LOIP LB-200 precision thermostatic baths with a bath depth of 200 mm. The composition of the kit: GOST 6321-92 Tripod for test bombs 1 pc. Test bomb 2 pcs. Tripod for test tubes 1 pc. Test tube P-2-16/150 20 pcs. Cork cork 20 pcs. Copper plate (40x10x2 mm) 50 pcs. Sandpaper 10 sheets Corrosion standard 1 pc. ISO 2160 Tripod for test bombs 1 pc. Test bomb 2 pcs. Tripod for test tubes 1 pc. Test tube P-2-26/150 11 pcs. Cork cork 11 pcs. Copper plate (75x12x2 mm) 50 pcs. Sandpaper 10 sheets Corrosion standard 1 pc.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SW-D3
Sulfur Analyzer SPECTROSCAN SW-D3
The analyzer is designed to determine the mass fraction of sulfur in automotive fuel in accordance with GOST R 52660-2006 / GOST ISO 20884-2016, ASTM D6334, as well as in oil and petroleum products according to GOST R 53203-2008 / GOST 33194-2014, ASTM D2622, GB/T 11140-2008. Depending on the customer's needs, the analyzer is configured to work in accordance with a particular standard. Implements an arbitration method for measuring the mass fraction of sulfur in automobile fuel of the third, fourth and fifth classes. The device is designed specifically for high-quality and fast X-ray fluorescence analysis of fuel in accordance with the technical regulations "On requirements for automotive and aviation gasoline, diesel and marine fuel, jet fuel and heating oil", which establishes an arbitration X-ray fluorescence wave dispersion method for determining the mass fraction of sulfur in automotive fuels of the third, fourth and fifth classes. The wave dispersion sulfur analyzer SPECTROSCAN SW-D3 is designed taking into account all the requirements for the process of X-ray fluorescence elemental analysis of low sulfur contents in petroleum products. The operator's actions when performing measurements are minimized: - the number/name of the sample is entered from the built-in keyboard; - the sample is poured into two cuvettes; - the obtained samples are placed in the analyzer and measurements are started. The analyzer performs all subsequent actions automatically without operator involvement: - calculates and displays the sulfur content in the sample; - calculates convergence - the difference in determining the mass fraction of sulfur in the first and second samples; - prints measurement results on the built-in printer.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Sulfur Analyzer SPECTROSCAN SE
Sulfur Analyzer SPECTROSCAN SE
The analyzer is designed to determine the mass fraction of sulfur from 3 million-1 (ppm) in oil and petroleum products in accordance with GOST R 51947-2002, GOST 32139-2019, GOST R EN ISO 20847-2010 / GOST ISO 20847-2014, ASTM D4294, GB/T 17040-2019. Implements an arbitration method for measuring the mass fraction of sulfur for oil, automotive fuels of class K2, K3, jet engine fuel, aviation gasoline, fuel oil and marine fuel, and is also used for operational control of sulfur content in automotive fuels of Class 4 and 5, gas oils, bitumen, lubricating oils and their components and other petroleum products. The analyzer greatly simplifies the routine analysis procedure. Intuitive interface provides convenience and ease of use. The analyzer is a proprietary development of NPO "SPEKTRON". The device is manufactured in St. Petersburg mainly from domestic components. Minimum operator actions: - calibration is selected and the name of the sample is entered; - two cuvettes are filled with a sample; - the obtained samples are placed in the analyzer and measurements are started; - all subsequent actions are performed automatically: - the average value of the mass fraction of sulfur is calculated and displayed; - repeatability is calculated; - the results are checked for compliance with the selected standard; - measurement results are printed on the built-in printer and saved.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
Diesel engine oil spectrometric analysis system "EXPRESS-OIL"
Diesel engine oil spectrometric analysis system "EXPRESS-OIL"
Diesel engine oil spectrometric analysis system "EXPRESS-OIL" is designed to analyze engine oils according to GOST 20759 and determine the concentration of wear elements of rubbing diesel parts, contaminants and additives in diesel engine oils during scheduled maintenance and repair of traction rolling stock in locomotive repair depots, as well as electronic accounting and analysis of dynamics data the content of wear elements in engine oils for each locomotive, as well as the determination of the composition of metals and alloys according to GOST, greases (according to CTCH-28/4, CTCHS-53) and other materials.
Produced in: Novosibirsk
A set of LAB-CTT devices for determining the flow temperature of petroleum products
A set of LAB-CTT devices for determining the flow temperature of petroleum products
The composition of the kit: LOIP FT-311-80 cryostat cover of special design 1 pc. A flat-bottomed test tube with a label of 2 pcs. Rubber ring-shaped gasket 4 pcs. Stopper with a hole for a thermometer 2 pcs. A disk made of cork 2 pcs. Cooling bath cover 2 pcs.
LOIP
Saint Petersburg
Produced in: Saint Petersburg