Search

73 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 68
    Names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • 35
    Additional
    Loading...
View:
73 products
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
Apparatus for determining the flash point in a closed crucible TVZ-LAB-01
The analyzer automatically heats the sample crucible and moves the test flame. The flash moment is set visually and recorded by pressing the "STOP" button, while the flash temperature is displayed on the display. Technical specifications: Flash temperature measurement range (with crucible cooling), °C from +40 to +400* The heating rate of the crucible with the sample, °C/min 0..20 Igniting a gas flame The speed of the stirrer, rpm 30...240 Power consumption from AC 220 V, no more, 600 W Overall dimensions of the device, not more than 350x250x280 mm Weight of the device, not more than, kg 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Thermostat for determining the density of LT-810
Thermostat for determining the density of LT-810
Technical specifications: Temperature range, °C - without external cooling (Current +10)...+100 - with tap water cooling (Tvody+5) +100 - with cryostat cooling LOIP FT-311-25 0 ...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of seats for cylinders 4 Cylinder dimensions (height*diameter), mm 500*50 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 30 Working fluid - up to 70 °C distilled water - above 70 ° C petroleum jelly or silicone oil, water-glycerin mixture Overall dimensions (WxDxH), mm 560x250x710 Weight of the device without liquid, not more than, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Bath for the determination of paraffins BF
Bath for the determination of paraffins BF
The volume of the bath is 5 liters Overall dimensions 420x280x500 mm The open part of the bath is 230x235 mm Weight 7.5 kg
Produced in: Tomsk
Analyzer of petroleum products in water "FLUORATE® AE-2"
Analyzer of petroleum products in water "FLUORATE® AE-2"
1 supp.
Technical specifications: The range of detectable concentrations 0.025-1.0 and 0.1- 10 mg/l from 10 to 100 mg/l –can be used as an alarm The temperature of the analyzed flow is from + 4 to + 50 °C The pressure in the flow is 0.1-10 atm. Number of measurements per hour 1-4 Output of results Digital scoreboard, RS485, RS232, 4-20 mA current loop Display modes NORM, ALARM, LIMIT Version B1, P1, N1 according to GOST 12997-84 Category of climatic performance UHL4 according to GOST 15150-69 Ambient temperature from + 5 to + 50 °C Relative humidity at + 25 °C 80% Atmospheric pressure 84-106.7 kPa The amplitude of external vibrations with a frequency of 10-55 Hz is not more than 0.15 mm Power supply 187-242 V, 50 ± 1 Hz from an autonomous source, 12 V Power consumption not more than 100 watts Dimensions 600x600x250 mm Weight 50 kg The warranty period of operation is 1 year Average service life of at least 5 years Average time to failure of at least 20,000 hours
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
Automatic Rapid Analysis device for turbidity/solidification temperature of petroleum products TPZ-LAB-12
TPZ-LAB-12 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-12 is a built–in cooling unit capable of cooling the test cell to -85 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests to determine the temperature of turbidity and solidification, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 4.5 ml Temperature range of the test cell -85...+51°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 250 W Overall dimensions 315x470x405 mm Weight 15 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
PU Desktop laboratory catalytic unit
PU Desktop laboratory catalytic unit
The PU desktop laboratory unit is an automated installation based on a mini–reactor with a fixed layer that has a volume of up to 1.5 cm3. The PU desktop laboratory unit is designed to perform kinetic studies, evaluate the properties of catalysts, model catalytic processes, test the stability of catalysts and sorbents. For maximum compliance with the customer's requests, the installation has a modular design with the possibility of adding new options. Main advantages: 1. Compactness; 2. Real-time parameter monitoring; 3. Easy maintenance; 4. Operation safety; 5. User-friendly interface. Applied tasks 1. Hydrogenation/dehydrogenation processes of hydrocarbons; 2. Fischer-Tropsch synthesis; 3. Catalytic cracking and isomerization; 4. Reforming of natural gases; 5. Hydrogenation processes; 6. Catalytic oxidation; 7. Hydrotreating processes. Basic equipment 1. Gas supply unit 2. Reactor unit 3. Separation unit 4. Sampling unit 5. Unit for measuring the volume of the outgoing gas 6. Control unit
Produced in: Rostov region, Novocherkassk
Octanometer OCTANE-IM
Octanometer OCTANE-IM
Digital indication of measured values • Fuel volume for measuring 50 cm3 The minimum immersion depth of the sensor is 90 mm The time of setting the operating mode is 3 seconds Overall dimensions 470x60x35 mm Weight 0.7 kg
Produced in: Tomsk
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
Automatic apparatus ATK-LAB-12 for determining the temperature of crystallization (freezing) by laser method
The parameters of accuracy, convergence and reproducibility are equivalent and correlate with the result obtained in accordance with manual methods ASTM D2386, GOST R 52332-2005, GOST 5066-91, ISO 3013, IP 16 The device is designed taking into account all the requirements of the standards for testing and is equipped with a built-in cooling system that allows the test cell to cool down to -100 ° C, without requiring external cooling. • Sample temperature detection range -100...25 °C Accuracy of determination of sample temperature ± 0.1 °C The temperature range of the test chamber is -100...30 °C The volume of the analyzed sample is 10 ± 2 ml Power consumption from the mains 220, not more than 250 watts USB, LAN interface Overall dimensions (WxHxD), not more than 250x450x360 mm Weight, not more than 12 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Thermostat for Raid bombs LT-820
Thermostat for Raid bombs LT-820
Design features: Microprocessor-based PID controller; Multifunctional control knob; Minimum temperature gradient over the entire volume of the bath; Three places to plant Raid bombs; Hole for the control thermometer; Stainless steel bathtub with glass windows; Built-in cooling heat exchanger; Self-diagnosis system; A faucet for draining the working fluid. Technical specifications: Temperature range, °C - without external cooling - with tap water cooling (Current+10)...+100 (Tvods+5)...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of places for Raid bombs 3 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 33 Working fluid - up to 80 °C - above 80 °C distilled water water-glycerin mixture Overall dimensions (WxDxH), mm 670x250x620 Weight of the device without liquid, kg 27
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Optical recorder of oil films "CRAB-1"
Optical recorder of oil films "CRAB-1"
1 supp.
Technical specifications: Sensitivity (minimum thickness of recorded oil films) from 0.5 microns The root-mean-square slope of the water surface up to 20 ° Distance from the receiving device up to 1000 m Sensor power supply 100-240 V, 50-60 Hz Power consumption up to 3 watts Ambient air temperature from -10 to +50 °C Humidity up to 100% (rain) Distance to the water surface 0.5–20 m Dimensions 120x180x120 mm Weight up to 1.5 kg
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
Automatic apparatus for analysis of turbidity/fluidity/solidification temperature of petroleum products TPZ-LAB-22
The parameters of accuracy, convergence and reproducibility are equivalent and correspond to the results obtained in accordance with the methods of ASTM D2500, ASTM D 97, GOST 20287 (methods A and B), GOST 5066 (for the determination of turbidity), GOST 5950, EN 23015, ISO 3015, ISO 3016, IP 15 TPZ-LAB-22 belongs to the latest generation of equipment of JSC "LOIP". The device is designed taking into account all the requirements of the standards for testing. A unique feature of TPZ-LAB-22 is a built–in cooling unit capable of cooling the test cell to -95 °C without the use of external cooling systems. The device automatically sets and maintains the temperature of the cooling bath, conducts tests, creates and stores test reports in memory. Technical specifications: The volume of the analyzed sample is 45 ml The operating temperature range of the test cell is -95...48°C Accuracy of temperature maintenance ± 0.5 °C Maintaining the temperature of the cooling bath Integrated cooling system Built-in memory of at least 1000 protocols Color LCD display with touch screen Supply voltage 220 V Power consumption 500 W Overall dimensions 300x560x550 mm Weight 25 kg
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Thermostat for determining oxidative stability LT-830
Thermostat for determining oxidative stability LT-830
Design features: Microprocessor-based PID controller; Multifunctional control knob; Minimum temperature gradient over the entire volume of the bath; Hole for the control thermometer; Stainless steel bathtub ; Built-in cooling heat exchanger; Self-diagnosis system; A faucet for draining the working fluid. Technical specifications: Temperature range, °C - without external cooling - with cooling with tap water (current +10)...+100 (Tvods+5)...+100 Accuracy of temperature maintenance, °C ± 0.1 Number of test places 4 Power consumption from the mains 220 V, W 2200 Volume of working fluid, l 30 Working fluid - up to 80 °C - above 80 °C distilled water water-glycerin mixture Overall dimensions (WxDxH), mm 560x250x710 Weight of the device without liquid, kg 25
LOIP
Saint Petersburg
Produced in: Saint Petersburg