Search

1059 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 299
    Names
    Loading...
  • 82
    Manufacturer
    Loading...
  • 42
    Made in
    Loading...
  • 70
    Additional
    Loading...
View:
1059 products
DOSIMETER‑RADIOMETER MKS‑AT1117M
DOSIMETER‑RADIOMETER MKS‑AT1117M
Depending on the set of detection units, the device is designed to measure: - ambient dose equivalent and ambient dose equivalent power of X-ray, gamma and neutron radiation; - kerma and kerma power in the air; - the directional dose equivalent and the power of the directional dose equivalent of continuous X-ray and gamma radiation; - the flux and fluence densities of alpha and beta particles from contaminated surfaces; - the flux and fluence densities of neutron radiation with a known energy distribution; - surface activity and number of decays of 239Pu and 90Sr + 90Y; - operational search for sources of ionizing radiation and radioactive materials.
Produced in: Belarus, Minsk
Droplet separator
Droplet separator
The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
Doza
Zelenograd
Produced in: Moscow
High-precision smart surface probe L =300 mm SZPWT.300P with built-in flash memory
High-precision smart surface probe L =300 mm SZPWT.300P with built-in flash memory
from 13 920 ₽
High-precision smart surface probe L =300 mm SZPWT. 300P with built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor, Android program installed. Operating conditions of the SZPVT smart probe.300P Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPVT smart probe.300P Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect external power. Possibility of calibration.
Produced in: Kolomna, Moscow region
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
Smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory
from 10 560 ₽
The smart submersible probe L=150 mm SZPG.150PM (d=2 mm) with built-in flash memory is designed to measure the temperature of various materials by direct contact of the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the installed ThermoMonitor, Android program. Operating conditions of the SZPG.150PM smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. Functionality of the SZPG.150PM smart probe Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor, Android program installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor, Android program installed. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Calibration capability.
Produced in: Kolomna, Moscow region
V-50-2 Industrial Frequency Magnetic Field Meter
V-50-2 Industrial Frequency Magnetic Field Meter
from 77 500 ₽
It is designed to determine the induction module of the industrial frequency magnetic field created by magnetic systems and electrical devices for various purposes, power lines, power supply systems, transport and other sources.
Produced in: Moscow
Smart probe for connecting an external thermoelectric converter with built-in flash memory
Smart probe for connecting an external thermoelectric converter with built-in flash memory
from 11 454 ₽
Designed to measure the temperature of various materials by direct contact of the probe with the measuring object. A smart probe for connecting an external thermoelectric converter with a built-in flash memory is designed to measure the temperature of various materials by directly contacting the probe with the measuring object and transmitting the measured value via Bluetooth to devices with the ThermoMonitor. The Android program is installed. Operating conditions of the SZVTP smart probe Ambient temperature, °C: -20...+55. Relative humidity, %: not more than 80 at T=35 °C. Atmospheric pressure, kPa: 86...106. The functionality of the smart probe SSVTP Measurement of physical quantities with a resolution of 0.01. Recording of measured values at intervals from 5 seconds to 23 hours 59 minutes 59 seconds (only smart probes with built-in memory). Transmitting data about measured physical quantities via Bluetooth to a device with the ThermoMonitor. The Android program is installed. Transmitting information about the state of charge of the built-in battery via Bluetooth to a device with the ThermoMonitor. The Android program isinstalled. Automatic transition to sleep mode after 50 seconds. The ability to connect an external power supply. Possibility of calibration.
Produced in: Kolomna, Moscow region
The verification complex ZM3003
The verification complex ZM3003
It has: a wide range of calibrated currents and voltages reproduction; wide frequency range at alternating current 20Hz – 20kHz; adjustment of the phase shift angle between current and voltage in the range 0 – 360 °; high accuracy of reproduction of current, voltage, phase shift angle. Normal operating conditions: ambient temperature (23 ± 5) ° C; the relative humidity of the surrounding air is 30-80 %; atmospheric pressure 84 — 106 kPa (630-795 mmHg); supply network voltage (220 ± 4.4) V; supply network frequency 48 — 62 Hz. Operating conditions: ambient temperature from 5 to 40 ° C; relative humidity up to 80 % at temperatures up to 30 ° C; atmospheric pressure 84 — 106 kPa (630 — 795 mmHg) supply voltage (220 ± 22) At a frequency of 48 — 62 Hz; The additional error in reproducing the voltage and strength of direct and alternating current, as well as the power from a change in the mains voltage by ± 10% of the nominal value of 220 V does not exceed half of the corresponding basic error. The additional error from the change in ambient temperature for every 10 ° C does not exceed half of the basic error. The electrical insulation resistance between the power supply circuits of the device and the housing is not less than: under normal conditions of use – 20 Mohm; at elevated ambient temperature — 5 Mom. The device can be used as part of automated measuring systems for various purposes with serial interfaces: RS-232C (EIA-2320) or USB. Overall dimensions: control unit 270 x448.8x496 mm, power unit 270 x448.8x496 mm. Weight: control unit 25 kg, amplifier unit 25 kg.
Produced in: Krasnodar
Digital two-channel contact thermometer TK-5.29 with universal inputs and logging function
Digital two-channel contact thermometer TK-5.29 with universal inputs and logging function
from 28 800 ₽
The digital contact thermometer TK-5.29 is designed to measure the temperature of liquid, bulk, gaseous materials by immersion of measuring probes of thermometers into the medium (immersion measurements), contact measurements of temperatures of surfaces of solids (surface measurements), measurement of relative humidity of gaseous non-aggressive materials, measurement of atmospheric pressure, measurement of air flow velocity, as well as for measuring the luminous flux incident on a small area of the surface to its area and other physical quantities by sensors with a unified current output. The contact thermometer TK-5.29, depending on the order, is equipped with replaceable probes for various purposes. A probe of any type can be simultaneously connected to the TK-5.29 thermometer to the 1st channel, a thermal resistance sensor or a sensor with a unified current output of 4 ...20 mA to the 2nd channel. The TK-5.29 thermometer has the function of automatically determining the type of connected probe.
Produced in: Moscow
Alpha-beta radiometer for measuring small activities UMF-2000
Alpha-beta radiometer for measuring small activities UMF-2000
A low-background alpha-beta radiometer with a silicon detector, widely used for measuring small activities. It is recommended for measuring the total alpha and beta activity of natural and drinking waters, as well as for measuring the activity of alpha-emitting radionuclides by spectrometric method. Purpose: measurement of the total activity of alpha-emitting nuclides in "thick" and "thin" counting samples of environmental objects; measurement of the total activity of beta-emitting nuclides in counting samples of soil samples, water samples, air filters and samples obtained by selective radiochemical extraction; measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by radiometric method (if available); measurement of alpha activity of nuclides in counting samples obtained after radiochemical preparation by the spectrometric method (if there are techniques and a set of spectrometric "UMF - Spectrum").
Doza
Zelenograd
Produced in: Moscow
Anemorumbometer Vetromer-1
Anemorumbometer Vetromer-1
from 208 548 ₽
Wind speed range: 0.7 – 55.0 m/s Direction range: 0 – 360° Accuracy Characteristics: Speed: PG±(0.3+0.05)m/s Direction: ±3° Power supply: AC 50 Hz 220 V (187-242 V) DC power supply 12±3 V Power consumption is 7 VA, 15 VA with heating turned on. Interface: Remote sensor: RS-485 (possibility of operation of one remote control with several sensors) or (on request) a current loop. Remote computer: USB or RS-232. By order: current loop – distance up to 10 km modem – remoteness is determined by the customer's requirements. Operating conditions: sensor – from -55C to +50C; measuring console and power supply – from +10C to +40C.
EMPGGO
Saint Petersburg
Produced in: Saint Petersburg
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for measuring the volumetric activity of radioactive aerosols UDA-1AB
Installation for continuous automatic monitoring of the concentration of radioactive aerosols in autonomous mode or as part of automatic radiation monitoring systems in the air of working rooms and ventilation systems. Purpose: measurement of the volumetric activity of alpha-emitting radionuclides and beta-emitting radionuclides contained in the form of aerosols in the air.
Doza
Zelenograd
Produced in: Moscow
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
RADIOACTIVITY INDICATOR IR‑AT2522 (ALPHA SENSOR)
Rapid assessment of surface contamination with alpha-active radionuclides, in particular, polonium-210. The device is easy to operate, suitable for use by personnel of any qualification, including at home. ▪ Scintillation detector ▪ Silicon photoelectronic multiplier ▪ High sensitivity ▪ Light and sound indication when registering alpha particles ▪ Long-term operation without recharging ▪ 1" OLED colour screen
Produced in: Belarus, Minsk