Measuring antenna P6-62
Measuring antenna P6-62
1 supp.
Technical specifications: Frequency range (300-1000) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 400x145x150 mm Weight 1 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
AF18-20dB
AF18-20dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, 20 dB Attenuation error, dB ± 1.0 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
PKV-IP-11×5.5
PKV-IP-11×5.5
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications the length of the waveguide, mm 11×5.5 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 17.44-25.96 VSWR 1.25
Produced in: Moscow
Digital oscilloscopes S8-54
Digital oscilloscopes S8-54
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 200 MHz. Description: 200 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 400 Mbps, in real time Color LCD screen with LED backlight Saving signals on external media in graphic and text form Cursor measurements and 22 types of digital measurements USB and Ethernet interface Frequency meter function Logger function.
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters H3-96
Frequency meters H3-96
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 3200 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz The number of averages. the period of the input signal is 1 ... 105 Borehole measurement by inputs – 1.000001- 999999999 Frequency ratio in channels: A/S, C/A, B/C and B/A - up to 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 2•10-8 - in 30 days, ± 5•10-8 - in 12 months Overall dimensions (HXHL) - 345x285x106 mm Weight: 4 kg Reference generator: ±5x10-8 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
Digital oscilloscope C8-43
Digital oscilloscope C8-43
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Description: 2 mV...10 V/div; 10 ns...100 s/del ADC: 2 channels, 100 MHz, 8 bits, 64 KB/channel Equivalent sampling rate of 10 GHz Marker measurements U: ±2.5%,T: ±1.5% Pre-start, averaging,filtering Familiar management interface High-quality, "live" image Additional modes in the "MENU" Low price Screen 80x100 mm (CRT made in Holland) Dimensions, weight: 120x300x380 mm, 7 kg Power supply: ~220V, 80 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
PKV-IB-7,2×3,4
PKV-IB-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
FNCH-45
FNCH-45
Basic properties Low bandwidth losses; A wide barrage strip. Operating conditions Operating temperature range from minus 10 up to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Bandwidth Fh-Fb at the level of -1 dB, GHz 37-45 The barrage band at the level of -30 dB, GHz 50-70 Bandwidth loss, 0.5-1.0 dB
Produced in: Moscow
VD-3.6×1.8
VD-3.6×1.8
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 3.6×1.8 Flange type according to GOST RV 51914-2002 Frequency range, GHz 53.57-78.33 VSWR 1.25 Losses, 2.5 dB Length, mm* 500
Produced in: Moscow