Search

1059 products
View:
  • Selected: 1
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Applying
    Loading...
  • 299
    Names
    Loading...
  • 82
    Manufacturer
    Loading...
  • 42
    Made in
    Loading...
  • 70
    Additional
    Loading...
View:
1059 products
Amplifier module MUS-04
Amplifier module MUS-04
The module uses connectors of the SMA type. At the request of the customer, any combination of output signals is possible. When installing two amplifier modules in the above devices, the total number of output signals increases to twelve.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Universal mobile complex for verification and repair of measuring instruments
Universal mobile complex for verification and repair of measuring instruments
The complex is equipped with air conditioning, heating and ventilation systems to create and maintain a set temperature level (20-25) ° C in the container body, at an outdoor temperature from minus 40 ° C to 40 ° C. Operating conditions Ambient air temperature from minus 40 to 40 ° C; Relative humidity up to 95 % at tº= 30 ° C; Atmospheric pressure from 84.0 to 106.7 kPa (from 630 to 800 mm Hg); General-purpose power supply: alternating three-phase current with a frequency of (50 ± 1) Hz with a RMS voltage value in each phase (380 ± 38) V. A set of functionally related working standards, special equipment and automation tools allows you to implement complex metrological maintenance of measuring instruments at automated (automated) and non-automated (RM) workplaces
Produced in: Moscow
Frequency comparator CHK7-1011
Frequency comparator CHK7-1011
Frequency comparators CHK7-1011 and CHK7-1011/1 can also be used as frequency and time standards with frequency correction based on GLONASS/GPS signals as sources of highly stable signals in various frequency measuring systems. Comparators have a built-in device for processing measurement data based on a microcomputer, which provides statistical processing of the results of frequency and time measurements, and a device for displaying information based on a color TFT display. The built-in diagnostic system allows you to quickly determine the operability and condition of the main comparator devices with information output to the built-in display screen. Comparators are available in three versions and differ in composition and functions performed. Comparators have a basic set of devices (modules), including a frequency comparator, a power supply module and a device for processing and displaying information based on a microcomputer and a color TFT display. The frequency comparator CHK7-1011 has a built-in SRNS receiver and a highly stable rubidium frequency standard Ch1-1014 with the function of correcting the actual frequency value by signals from satellite radio navigation systems GLONASS or GPS. The comparator forms its own time scale with the ability to synchronize on any external time scale received by the SRNS receiver built into the device. The device has two modes for measuring the deviation of the generated time scale: from the time scale of the built-in SRNS receiver and from the external time scale. Information about the current time received from the SRNS receiver is displayed on the comparator display screen, and is also transmitted to the consumer via the RS-485 interface. All the above-mentioned features make the frequency comparator CHK7-1011 a unique measuring device in the field of frequency and time measurements. The frequency comparator CHK7-1011/1 has a highly stable rubidium frequency standard Ch1-1013 and can be used as a frequency and time standard as a source of highly stable signals in various frequency measuring systems. The frequency comparator CHK7-1011/2 does not include any additional devices. To carry out measurements with it, it is necessary to use a highly stable signal of the reference frequency from an external RF or hydrogen frequency standard. For the convenience of users, apart from the keypad, they can also exercise control of the functions of the devices with a mouse-type manipulator included in the delivery package. Comparators provide access to measurement data over an Ethernet network.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
Rubidium frequency standard H1-1014
Rubidium frequency standard H1-1014
The built-in time scale shaper provides a pulse signal of 1 c at the output of the device. Its small dimensions, weight, power consumption, and operating time allow it to be widely used as an embedded source of high-stability signals in frequency measuring devices and complexes, telecommunications systems, navigation and communication systems. It includes a frequency binding module based on a pulse signal of 1 s from an external time scale or from a SRNS GLONASS/GPS receiver and a tunable frequency synthesizer with the ability to adjust the frequency via the RS-232 interface. The built-in binding module allows the device to be used when operating in automatic correction mode as a source of a highly stable signal with a frequency error of ± 5 · 10-12 per day.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Verification module PM-3
Verification module PM-3
The composition of the PM-3 verification module: Frequency comparator CHK7-1011; Universal frequency meter Ch3-86A; Universal voltmeter V7-79; Absorbed power wattmeter M3-108-2; High-frequency signal generator G4-229; High-frequency signal generator G4-230; Generator of test pulses G9-1A; Oscilloscope S1-177; DC power supply B5-79/1; Electronic switchboard of RF signals; AC power source B2-7 (2 pcs.); PC, printer; Basic load-bearing structures (BNC). Technical specifications Measurement ranges of time-frequency parameters of signals: Continuous oscillation frequency from 0.005 Hz to 17.85 GHz Pulse repetition rate from 0.01 Hz to 100 MHz The carrier frequency of the IM signal is from 100 MHz to 17.85 GHz Pulse duration from 10 ns to 1000 s Time interval from 0 to 1000 s Nominal values of the frequency of the studied signals are 2,048; 5,0; 10,0; 10,24 MHz Measurement errors of time-frequency parameters of signals: Frequency of continuous oscillations ± (2,4·10-10 - 4·10-3) Pulse repetition rate ± (2·10-7 - 2·10-3) The carrier frequency of the IM signal is ± 2·10-7 Pulse duration ± (1 - 200) ns Time interval ± (1 - 200) ns The relative deviation of the frequency of the studied signal from the reference frequency ± (5·10-13 - 2·10-12) Frequency of continuous oscillations ± (3·10-11 – 1,1·10-5) Pulse repetition rate ± (2·10-11 – 6·10-5) Carrier frequency of the IM signal ± (3·10-11 – 1,1·10-5) Pulse duration ± (1·10-8 – 7,2·10-4) Time interval ± (2·10-10 – 7,2·10-4) Nominal values of the reference signal frequency ± (2·10-11 – 2,4·10-10) General technical characteristics: The area occupied by the module is 8-12 m2 Weight, not more than 327 kg Power supply voltage from 198 to 242 V frequency (50 ± 0.5) Hz Power consumption, no more than 2400 VA
Produced in: Moscow
Frequency comparator Ch7-1014
Frequency comparator Ch7-1014
Since it is reliable and easy to operate, the device is widely used in metrological centers, measuring laboratories, at the workplaces of REA developers. The comparator Ch7-1014 has a communication interface with an external personal computer USB 2.0 and application software for an external PC. At the request of the customer, the comparator can be supplied complete with a laptop or tablet computer with installed software.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
AF18-30dB
AF18-30dB
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Nominal attenuation, dB 30 Attenuation error, dB ± 1.5 VSWR 1.4 Frequency range, GHz 0-18 Input power, W 1 Type of coaxial connectors (according to GOST RV 51914-2002) IIIB-IIIP
Produced in: Moscow
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
Oscilloscope S1-167/2
Oscilloscope S1-167/2
Designed for the study of periodic electrical signals by visual observation and measurement of their amplitude and time parameters on the scale of the CRT screen in the frequency band 0 - 25 MHz with a built-in multimeter measuring voltage and DC power, the average square value of voltage and AC power, DC electrical resistance. Technical specifications: Vertical deviation Number of channels 2 Bandwidth 0-25 MHz Deviation coefficients 2 mV/div-10 V/div (step 1-2-5) Installation error ± 3% Rise time of PH <= 14 nsec Input impedance 1 mOhm/23 pF, with divider 1:10-10 mOhm/12 pF with open input <=110 V with closed input <=110 V with divider 1:10 <= 250 V range U post. U AC: 1 mV–500 V Error 0.1% (U post); 0.3% -1% (U perem. 40 Hz–100 kHz) Range I post., I AC.: 1 mA–2 A Error: 0.25% (I post.); 0.5% (I perem. 40 Hz–5 kHz) R Range: 1 Ohm–1 mOhm Error R: 0.2% 3.5-digit indicator Automatic selection of limits.
MNIPI
Minsk
Produced in: Belarus, Minsk