Washing table LAB-M MD13 ME 80.60.90 SS
Washing table LAB-M MD13 ME 80.60.90 SS
Furniture for laboratory work. Washing table on a support pedestal made of metal LAB-M MD13 ME 80.60.90 SS Width, mm: 800 Depth, mm: 600 Height, mm: 900 equipment: The table top is a single module made of SUS 201 stainless steel (analogous to AISI 201). Attention! The product is recommended to be used only for work with non-aggressive substances. For work with various reagents, in addition to mineral acids, it is recommended to use washing tables made of AISI 304 stainless steel. Inner bowl size – 340*400*130 mm, 2 bowls The base of the sink table is a metal support pedestal. The lower part is an all–welded frame painted with dark gray powder paint RAL 7011. The bottom and top of the housing are sheet steel painted with powder paint of dark gray RAL 7011, the side walls are made of sheet steel painted with powder paint of white RAL 9016. Facades – laminated MDF of white color with a thickness of 16 mm, dark gray ABS edging
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory work table low LAB-PRO SLn 150.65.75 KG-ESS
Laboratory work table low LAB-PRO SLn 150.65.75 KG-ESS
Laboratory work desk Working surface: KG-ESS (porcelain stoneware) with a side made of n/w steel Length, mm: 1500 Depth, mm: 650 Height, mm: 750 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Industrial Drying Cabinet SNOL 3000/5
Industrial Drying Cabinet SNOL 3000/5
High-temperature industrial drying cabinet SNOL 3000/5 with a working chamber volume of 3000 liters and a maximum operating temperature of 500 degrees with software
Produced in: Tula
LB12-Sh Laboratory bath
LB12-Sh Laboratory bath
It is designed for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. One workplace with a diameter of 110 mm with five steel O-rings, a tripod and a foot with a clip. Stamped steel bath with a volume of 3.5 liters and a depth of 110 mm. Bath volume 3.5 l Overall dimensions 405x345x660 mm The open part of the bath is 235x130 mm Bath depth 110 mm Weight 6 kg Power consumption 2.5 kW
Produced in: Tomsk
Electric cabinet vacuum drying SNVS-3.3,5/3-I2P
Electric cabinet vacuum drying SNVS-3.3,5/3-I2P
Electric vacuum drying cabinet SNVS-3.3,5/3-I2P is designed for drying and heating various materials in air and in vacuum at temperatures up to 300 ° C.
Produced in: Tula
Wall-mounted low table LAB-PRO SPCn 90.80.75 LA
Wall-mounted low table LAB-PRO SPCn 90.80.75 LA
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Rear side boxes Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vibrating liquid density meter VIP-2MR
Vibrating liquid density meter VIP-2MR
The operation of the density meter is based on measuring the oscillation period of a hollow tube of the original configuration filled with the liquid under study, and then calculating the value of its density using the results of preliminary calibration for two substances of known density, for example, air and water. • Maximum viscosity of the measured liquid at ambient temperature 300 mm2/s The nominal volume of the measuring cell is 1.5 ml Measurement time of 2 channels 20 s • Temperature range of the built-in thermostat +15...+60 °C • • Overall dimensions 205x225x80 mm Weight 3 kg Power consumption 15 W
Produced in: Tomsk
Electric cabinet vacuum drying SNVS-150/0-I2
Electric cabinet vacuum drying SNVS-150/0-I2
The electric vacuum drying cabinet SNVS-150/0-I2 is designed for degassing and setting the selected program (20 programs / up to 20 steps) of the vacuum depth with automatic maintenance of the set value.
Produced in: Tula
VD-12NFP Eddy Current Flaw Detector with 2 converters
VD-12NFP Eddy Current Flaw Detector with 2 converters
from 292 500 ₽
The device allows you to detect surface defects like cracks, visualizing the signal from the continuity interruptions on the display. The design of the flaw detector allows to determine with high reliability the exact location and depth of defects even on rough surfaces of flat and curved shape, including under a layer of corrosion or in the presence of a protective coating of the controlled area of the product with a thickness of up to 3 mm. The principle of operation of the VD-12NFP eddy current flaw detector: The principle of operation of the VD-12NFP eddy current flaw detector is based on the phenomenon of electromagnetic induction. An alternating magnetic field created in the primary coil of the converter by means of a sinusoidal voltage generator excites eddy currents in the controlled product. A parasitic magnetic field formed by eddy currents at the locations of defects affects the measuring unit (two signal coils connected in series) of the converter, creating an electromotive force in it. The amplitude and phase of the secondary signal carries information about the properties of the defect and the position of the transducer relative to the surface of the controlled product. The output signal from the measuring unit of the converter, after amplification and processing using a microprocessor, is displayed on the readout of the device, and is also stored in the memory block for subsequent transmission to a personal computer. In addition, information about the defects is displayed on a piezoelectric bell used as an audio indicator. Design, features and advantages of the VD-12NFP eddy current control device: The VD-12NFP eddy current flaw detector is a portable device capable of working both in a desktop and in a suspended position in a special bag-case. This ensures convenient operation of the device in a variety of conditions: in the laboratory, in the factory shop or during field tests. The flaw detector consists of an electronic unit with controls and display of test results, as well as three replaceable converters with wear-resistant corundum tips connected to the electronic unit using a connector. The choice of the desired converter depends on the magnetic properties of the material. For the control of parts with grooves, a converter with an inclined tip is offered. The device is powered by 4 AA batteries located in the battery compartment of the electronic unit. The advantages of the flaw detector include: - a screen for visualizing the signal during measurement; - light weight and compact dimensions that allow you to use the device in almost any conditions; - the ability to control the quality of products of various curvature and surface roughness even in the presence of a protective coating or a layer of corrosion; - wear resistance of converters, which is important when monitoring products with increased surface roughness (up to Rz£320); - automatic detection of the type of converter when connected, as well as the presence of built-in memory for storing control results; - the possibility to transfer data to a personal computer for storing or printing control protocols. Scope of application: Portability, high productivity, the ability to work with curved and rough surfaces, as well as the fact that the operation of the flaw detector is practically unaffected by humidity, pressure and contamination of the gas environment or the surface of the controlled product with non-conductive substances ensure the versatility of the device for detecting cracks in various materials. The eddy current flaw detector VD-12NFP is actively used in heavy industry for diagnostics of metal structures, assemblies and mechanisms for various purposes in factory workshops or laboratories, including at enterprises of railway transport, automotive industry, mechanical engineering, pipelines and metal structures. The VD-12NFP flaw detector can be used with equal success in the field, factory workshops, depots, laboratories and workshops to monitor the current condition, as well as to assess the degree of wear, the possibility and duration of further operation of such products made of metals and alloys as over-spring beams, wagon wheels, auto coupler housings, side frames, wheel couples and others. Distinctive features: • control of parts with surface roughness up to Rz320 due to wear-resistant corundum tips; • assessment of the degree of danger (depth) of the defect; • automatic detection of the converter type; • microprocessor control; • 5 universal programs for saving settings; • capable of detecting defects with a depth of 0.3 mm • The angle of deviation of the converter from the normal to the working surface up to 60° • Operating frequency of 70 kHz; • Maximum working clearance of 3mm; • visualization of the signal from the defect; • built-in memory for storing control results • Equipped with a Bluetooth 2.0 wireless communication module, which allows you to transmit control results and control the flaw detector at a distance of up to 20m; • The possibility of forming a control protocol based on the data transmitted to the PC; • Temperature range from 0°C to +40°C; • The design allows you to work with the flaw detector without removing it from the bag-case. Basic kit: Ia5.173.016: 1 electronic unit Ia5.125.031: 1 converter, type 1; marked as (•) Ia5.125.030: 1 converter, type 2; marked as (••) Ia2.706.002: the KOIDZ-VD set of samples with a passport (consisting of: Ia8.896.034: 1 piece; Ia8.896.035: 1 piece; Ia8.896.035-01: 1 piece) - A certificate of verification. 4 AA batteries 1 charger 1 small-sized phone 1 CD with software 1 special key 1 bag-case A calibration certificate is issued for the VD-12NFP flaw detector. 1 passport 1 operating manual 1 calibration instruction
Produced in: Moscow
Circulation thermostat LT-316b
Circulation thermostat LT-316b
Technical specifications: Temperature range: without external cooling, °C Current +10 ... +150 with tap water cooling °C Tvods+5 ...+150 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 8,0 pressure, 0.25 bar Bath volume, l 16 Working fluid water, water-glycerin mixtures, silicone oil The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x400 Weight, kg 12.8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
CRYO-VT-90 Low-temperature liquid thermostat
CRYO-VT-90 Low-temperature liquid thermostat
It is designed to maintain the set temperature of the coolant circulating in the connected external consumers. Feed pump for external closed-type thermostating systems. Cooling capacity 300 W at -80 °C. An internal bath with a volume of 9 liters and a depth of 200 mm. The operating temperature range is -90...+100 °C. Overall dimensions 510x800x1230 mm Weight 120 kg Power consumption 4.2 kW.
Produced in: Tomsk
Laboratory work table high LAB-PRO SLv 180.65.90 SS
Laboratory work table high LAB-PRO SLv 180.65.90 SS
Laboratory work desk Working surface: STEEL (single stainless steel module with anti-spill side) Length, mm: 1800 Depth, mm: 650 Height, mm: 900 BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg