Electronic explosion-proof thermometer ExT-01/2-6
Electronic explosion-proof thermometer ExT-01/2-6
The thermometer sensor ExT-01/2-6 is made in the form of a fully submersible probe with a cable length of 6 meters. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-NTS
Laboratory electronic thermometer LTA-NTS
LTA-NTS provides an error of ± 0.05 °C in the range of measured temperatures from -50 to +300 ° C The sensor is made of stainless steel with a heat-resistant cable that can withstand temperatures up to +200 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-P
Laboratory electronic thermometer LTA-P
LTA-P provides an error of ± 0.5 °C in the range of measured temperatures from -70 to +500 ° C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Pressure gauge MTIf-250
Pressure gauge MTIf-250
It is designed for the use with Raid bombs BR 01T, BR 02T in determining the absolute vapor pressure of volatile crude oil and volatile non-viscous petroleum products in accordance with GOST 1756. Pressure gauge with a range of measured pressure 0...250 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm Weight 1.5 kg
Produced in: Tomsk
TL-1MP Eddy Current Thickness Gauge
TL-1MP Eddy Current Thickness Gauge
from 965 000 ₽
The principle of operation of the electroplating thickness gauge: A converter with an induction coil on a ferrite core generates a high-frequency signal (frequency 1 MHz), which is used to create an alternating magnetic field. As the converter approaches the conductive surface, an alternating magnetic field creates eddy currents, the magnitude of which depends on the characteristics of the metal base and the thickness of the coating. In turn, eddy currents create their own electromagnetic field, which can be received by an induction coil. The resulting signal enters the amplitude detector, after which it is transmitted to the processing unit, where it is digitized and displayed on the device readout. In addition to signal conversion, the processor is used to set the required gain, as well as the initial voltage offset, depending on the characteristics of the materials in the controlled object. Features of the device design and advantages of the measurement method The TL-1MP eddy current thickness gauge consists of an electronic unit with a display, a power supply and a converter. The device is controlled using four buttons located on the front panel of the electronic unit. The converter can be disconnected from the electronic unit during transportation or for convenience of storage. The advantages of the device include: - convenience and ease of operation; - small size and light weight, allowing the TL-1MP to be used in difficult conditions with limited access to the controlled area of the facility; - high measurement accuracy; - factory setting of the measuring instrument to the customer's requirements; - high degree of localization of defects due to the small size of the converter. Scope of application: The service life of metal parts and components of mechanisms used in mechanical engineering is largely determined by their resistance to corrosion and surface wear. However, not all metals are sufficiently resistant to external destructive influences. Therefore, various electroplating coatings made of zinc, nickel, chromium, cadmium, tin, copper, silver and other metals are used to protect them. Even small fluctuations in the thickness of protective coatings can significantly affect the performance characteristics of parts, their service life, and interaction with other components. Therefore, measuring the thickness of the metal coating applied by the electrochemical method is important when conducting quality control of products. The use of the TL-1MP eddy current thickness gauge allows non-destructive quality control of electroplating coatings on the surface of metal parts in mass production conditions with special requirements for product quality. The device detects even small mechanical defects, the effects of abrasion, erosion, corrosion on the surface. Due to its ease of use, efficiency and reliability, eddy current thickness measurement is a standard method of quality control of products with electroplated coatings in such industries as mechanical engineering, aerospace industry.
Produced in: Moscow
Laboratory electronic thermometer LTA-NT
Laboratory electronic thermometer LTA-NT
LTA-HT provides an error of ±0.05 °C in the range of measured temperatures from -50 to +300 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-N
Laboratory electronic thermometer LTA-N
The error is ± 0.05 °C in the range of -50...+300 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-M
Laboratory electronic thermometer LTA-M
The error is ±0.2 °C in the range of -196...+300 °C. The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Pressure gauge MTIf-100
Pressure gauge MTIf-100
Pressure gauge with a range of measured pressure 0 ... 100 kPa. Accuracy class 0.4 Connection size M20x1.5 mm Overall dimensions 160 mm
Produced in: Tomsk
Electronic explosion-proof thermometer ExT-01/3-20
Electronic explosion-proof thermometer ExT-01/3-20
The thermometer sensor ExT-01/3-20 is made in the form of a fully submersible probe with a cable length of 20 meters and has a device for winding it. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk
Laboratory electronic thermometer LTA-MF
Laboratory electronic thermometer LTA-MF
LTA-MF provides an error of ±0.2 °C in the measured temperature range from -196 to +200 °C The minimum immersion depth of the sensor is 75 mm Overall dimensions of the electronic unit 80x75x100 mm Weight 0.25 kg
Produced in: Tomsk
Electronic explosion-proof thermometer ExT-01/3-30
Electronic explosion-proof thermometer ExT-01/3-30
The thermometer sensor ExT-01/3-30 is made in the form of a fully submersible probe with a cable length of 30 meters and has a device for winding it. The thermometer has an explosion protection marking 0Ex ia IIB T4 Ga X and can be used in explosive zones 0, 1 and 2 of any classes of premises and outdoor installations in which the formation of explosive mixtures of categories IIA, IIB is possible. • Measurement range -50...+130 °C Minimum sensor immersion depth full immersion Overall dimensions of the electronic unit 135x65x40 mm Electronic unit weight 0.3 kg
Produced in: Tomsk