LA-230 cooling heat exchanger
LA-230 cooling heat exchanger
Inner diameter, mm 6 Outer diameter, mm 8
LOIP
Saint Petersburg
Produced in: Saint Petersburg
NV-1200 VG Anti-vibration table for scales (1200×600×750)
NV-1200 VG Anti-vibration table for scales (1200×600×750)
from 15 447 ₽
The NV-1200 VG is a specialized laboratory table with a damping concrete slab on a sand cushion. It is designed to accommodate sensitive analytical equipment, primarily scales. Dimensions when assembled: 1200×600×750 mm. It is designed to work while sitting. The table has a reinforced metal frame. The main countertop has a built-in drawer open from above, which contains a sand cushion. It is closed with a heavy concrete slab attached to a second, smaller countertop. The sand cushion and the concrete base of the second countertop provide good protection against vibrations. Working surface material: laminate. It is well suited for the placement of devices, but is not resistant to concentrated acids, alkalis and organic solvents. The size of the anti-vibration countertop: 400×400 mm. For maximum isolation from vibrations, the scales should be placed in the center of this countertop. The tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard 16 mm thick) are edged with a durable PVC edge 2 mm thick, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor.
NV LAB
Moscow
Produced in: Moscow, Moscow region
2VVN1-25 water ring vacuum pump
2VVN1-25 water ring vacuum pump
The use of a 2VVN1-25(H) water-ring vacuum pump for pumping out water-gas mixtures is allowed only if the bulk of the water is separated and discharged at the pump entrance. Failure to comply with this requirement may lead to unacceptable overload of the electric motor and destruction of the working parts of the 2VVN1-25(H) pump. The 2VVN1-25(H) vacuum water ring pump is manufactured in the climatic version of UHL 4 and O4 (i.e. for moderate and cold climate) according to GOST standard 15150-69, meets the requirements of technical specifications TU 3648-015-00218526-2000, designed and manufactured taking into account the requirements of GOST R 52615-2006. The quality of electricity must meet the requrimemnts of GOST 32144-2013.
Produced in: Kazan
2NVBM-630(R)/12000 Booster High Vacuum pump
2NVBM-630(R)/12000 Booster High Vacuum pump
The 2NVBM-630(R)/12000 booster pump consists of housings, a steam pipe, a trap and a heater. The required effective speed of action of the pre-vacuum pump (pumps) at a pressure of 200 Pa (1.5 mm Hg) at the outlet of the 2NVBM-630(R)/12000 booster pump is not less than 100 l/s. The maximum residual pressure of the pump measured by the PMI-2 manometric ionization converter with nitrogen filled into its trap, is no more than 6.6x10-4Pa (5x10-6mm Hg). The pressure of the cooling water at the pump inlet 2NVBM-630(P)/12000 should be from 0.2 to 0.5 MPa (from 2 to 5 kgf / cm2) The discharge from the pump should be free with a jet break. Cooling water consumption 1200 l/h. The total amount of working fluid for the 2NVBM-630(R)/12000 pump is 65 liters, the level of the working fluid should be between the upper and lower marks of the level gauge. Replacement or refilling of the working fluid depends on the operating mode of the pump (inlet pressure, pumping duration, etc.) and the composition of the pumped medium, so the time after which the working fluid is replaced or refilled can be 100 hours or more. A large flow rate of the working fluid is observed when the pump is operating in the input pressure range from 1.33 to 13.3 Pa (from 1x10-2 to 1x10-1 mmHg). The operating mode of the pump in the range from 13.3 Pa (0.1 mmHg) to the maximum residual pressure is cyclically irregular.
Produced in: Kazan
Water bath for six persons LOIP LB-160
Water bath for six persons LOIP LB-160
Temperature range, °C (Current +5) ... +105 Accuracy of temperature maintenance, °C ± 1 Temperature setting error, °C ± 1 Power consumption from AC 220 V, no more, 1600 W Number of jobs, pcs 6 The diameter of the workplace, mm 110 Volume of working fluid, l 13 Useful part of the bath / depth, mm 428x300 / 62 Overall dimensions, mm 530x330x140 Weight of the device without liquid is not more than kg 7
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Vacuum drying cabinet with manual control SNVS-40/5
Vacuum drying cabinet with manual control SNVS-40/5
from 440 732 ₽
The SNVS-40/5 vacuum drying cabinet with a volume of 40 liters with manual vacuum adjustment is designed for heat treatment of materials at temperatures up to 500 with air access and in a vacuum controlled by manual valves. Thanks to modern temperature control, it demonstrates excellent performance of heat treatment modes. The measurement system complies with Russian standards and has certificates of entry into the SI State Register. Design for heat treatment in production and clean laboratories. The cabinet can be equipped with a software control device with an automatic timer and a wide selection of additional options.
Produced in: Tula
Laboratory low weight table SV-150.64.76.KRG
Laboratory low weight table SV-150.64.76.KRG
The table is 760 mm high with a countertop measuring 1500×640 mm. It is designed for long-term operation, the power frame does not contain aluminum and plastic parts in the fasteners. Overall dimensions of the external table 1500x640x760 mm Overall dimensions of the inner table 600x400x760 mm
Produced in: Tomsk
MARK® 509 hydrogen meter
MARK® 509 hydrogen meter
Measurement of the concentration of dissolved hydrogen (CRV), including "ultra-low", and the temperature of aqueous media. Continuous monitoring of parameters of water-chemical regimes at thermal and nuclear power facilities. Two channels | Freely programmable measurement ranges. The possibility of independent measurements at two points. Convenience and accuracy of measurement, minimum maintenance | Automatic temperature and barocompensation. Long-lasting, highly stable sensor | The service life of the sensor is at least 10 years. The possibility of placing the converter unit at a remote distance | from the sampling point Up to 100 meters. Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output. Durable aluminum housing IP65 | The device is reliably protected from dust and moisture. Graphic indicator with backlight | Convenient data presentation format and ease of settings
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
MARK-603
MARK-603
Measurement of electrical conductivity (UEP, UEP25), equivalent salinity and temperature of water and aqueous solutions, including deionized and "ultrapure". Operational control of water-chemical regimes at thermal power facilities. Control of electrical conductivity of water for laboratory analysis of 1, 2 degrees of purity according to GOST 52501-2005. 24-month warranty for deliveries across the Russian Federation Double automatic temperature compensation (ATC) Allows high-precision measurements of the conductivity of "ultrapure" water Selection of the coefficient of thermal compensation at the request of the User Stainless steel flow-immersion sensor Does not require calibration. The sensor design ensures the stability of the permanent cell Electronic notebook Ability to record up to 500 measurement groups in User-named folders Self-diagnosis Ion exchange column with sample current switch IP65 The compact sealed device is reliably protected from dust and moisture USB port, software included Graphic indicator with backlight Low power consumption Up to 600 hours of continuous operation from a set of AA type elements
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
Low laboratory work table LAB-PRO SLn 150.65.75 TR-E16/23
Low laboratory work table LAB-PRO SLn 150.65.75 TR-E16/23
BASIC EQUIPMENT The base is a collapsible frame made of rectangular steel profile, painted with powder paint (RAL 7035) with the texture of shagreen leather Hidden fasteners Two easily removable rear screens (RAL 7035) and one non-removable (RAL 5023) Adjustable supports (0-40 mm)
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Aquadistillator electric ADE-50
Aquadistillator electric ADE-50
from 127 000 ₽
Purpose: obtaining distilled water of 3 types according to GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Capacity: 50.0 (-10%) l/h Heating elements: Heating element 3.5 kW 220V (9 pcs.) Quality of produced water: GOST R 58144-2018 "Distilled water", FS.2.2.0020.18 "Purified water" Type of current, frequency, voltage: alternating three-phase, 50 Hz, 380 V (±10%) Power consumption: 31.5 kW Overall dimensions (L×W×C), mm: 700x500x800 Weight: 40 kg Warranty period: 14 months from the date of sale Registration certificate for a medical device No. FSR 2008/03708 of December 05 , 2008 Electrical conductivity of the produced water: 3-4.5 microns/cm The temperature of the produced water: from 70 to 85 ° C Source water flow rate (at 10 °C water temperature): 380 (±10%) l/h Source water pressure: 0.1-0.4 MPa Overall dimensions of the control unit (L×W×C), mm: 310x220x395 Execution: Outdoor Service life: at least 8 years
Livam