LB42-Sh Laboratory bath
LB42-Sh Laboratory bath
It is intended for thermostating samples in glasses, flasks and other laboratory utensils in cases where high accuracy of temperature maintenance is not required and good uniformity of the temperature field in the working volume is not needed. The operating temperature range is Current +5...+200 °C. Four workstations with a diameter of 110 mm with five steel O-rings, tripods and feet with a clip. Stamped steel tub with a volume of 13 liters and a depth of 110 mm. Bath volume 13 l Overall dimensions 540x640x660 mm The open part of the bath is 325x290 mm Bath depth 110 mm Weight 10.5 kg Power consumption 2.5 kW
Produced in: Tomsk
Cabinet LAB-M SHO 50.50.194
Cabinet LAB-M SHO 50.50.194
Furniture for laboratory work. Wardrobe Length, mm: 500 Depth, mm: 500 Height, mm: 1940 PACKAGE CONTENTS body – white melamine with a thickness of 16 mm, ABS edge dark gray facade – white melamine with ABS edge dark gray 1 branch 2 built-in shelves (1 for hats, 1 for shoes).
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Muffle furnace LF-7/13-G1
Muffle furnace LF-7/13-G1
Design features: Durable ceramic muffle; Semi-open heaters on four sides of the chamber Microprocessor temperature controller; Conveniently located control panel and bright LED display; Automatic shutdown of heating when opening the door; Ease of management and control; LED indicators of heater operation and protection operation; Alarm when the current temperature exceeds the limits of the permissible range; Highly efficient thermal insulation of the housing; The furnace body is made of high-quality sheet steel and painted with heat-resistant powder paint. Technical specifications: Maximum heating temperature, °C +1300 Temperature stability in steady-state thermal mode, °C ± 10 Warm-up time to the maximum temperature, no more than 120 min Dimensions of the working chamber, WxHxD, not less than 200x110x285 mm Overall dimensions, WxHxD, not more than 505x565x655 mm Rated supply voltage, 220 V Rated power, W 3300
LOIP
Saint Petersburg
Produced in: Saint Petersburg
TS-V-1 Dry Cooler
TS-V-1 Dry Cooler
from 67 173 ₽
Dry coolers (autonomous cooling system) are designed to circulate and cool the liquid, which ensures the permissible temperature of the heat-generating object. The product is adapted to work with vacuum drying cabinets of the "SNVS" and "SHSV" type manufactured by TULA-TERM LLC, having a liquid-cooled flange, as well as any equipment using liquid cooling and suitable in characteristics.
Produced in: Tula
Circulation thermostat LT-216a
Circulation thermostat LT-216a
The LOIP LT-216a modification device consists of an immersion thermostat-circulator LOIP LT-200 and a working bath with a flat removable lid. Technical specifications: Temperature range: without external cooling, °C Current+10 ... +200 with tap water cooling °C Tvods+5 ...+200 Accuracy of temperature maintenance, °C ± 0.1 The error of setting the set temperature, no more than ° C ± 0.2 Heater power, W 2000 Pump: max. flow rate, l/min 10.5 pressure, 0.27 bar Bath volume, l 16 The working fluid is water, water-glycerin mixture, silicone oil. The open part of the bath / depth, mm 190x296/200 Overall dimensions, mm 355x335x42 0 Weight, kg 11.5
LOIP
Saint Petersburg
Produced in: Saint Petersburg
LB12-18/8K Basket
LB12-18/8K Basket
Eight holes with a diameter of 17 mm will serve to accommodate glass tubes, the remaining nine ventilation holes — for better convection of the coolant. Internal dimensions 240x120x210 mm Weight 1 kg
Produced in: Tomsk
AO-3 cooler
AO-3 cooler
1 supp.
According to the requirements of the standards, the cooler is included in the list of equipment for determining humidity with pre-drying. Usually, grain samples after preliminary drying are cooled in the laboratory room to ambient temperature. However, with such cooling, the ambient temperature reaches only the surface layers of the samples, which affects the results of the analyses. The principle of operation of the cooler is based on blowing sample canopies in mesh buckets placed on a stand by a fan rotating at high speed. Advantages: Rapid cooling of samples. Stable moisture distribution. Allows you to significantly improve the accuracy of the results of determining humidity.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
cabinet LAB-M SHO 80.50.194
cabinet LAB-M SHO 80.50.194
Furniture for laboratory work. Wardrobe Length, mm: 800 Depth, mm: 500 Height, mm: 1940 PACKAGE CONTENTS housing – melamine white with a thickness of 16 mm, ABS edge dark gray facades – melamine white with ABS edge dark gray 2 compartments (in the left - a shelf for hats, a rod for hangers, in the right - a shelf for shoes, a rod for hangers).
LOIP
Saint Petersburg
Produced in: Saint Petersburg
hydrogen meter MARK® 509 A
hydrogen meter MARK® 509 A
Continuous measurements of dissolved hydrogen concentration and temperature of aqueous media with excess hydrostatic pressure up to 20 MPa Unique, patent-protected sensor design | Stability of operation with changes in hydrostatic pressure | Permissible short-term (up to 5 minutes) pressure overload (water hammer) – up to 40 MPa | Easy and fast membrane replacement | The sensor is not afraid of "drying" | The calibration interval is 6 months | Communication with external devices | Galvanically isolated current outputs 0-5/4-20/0-20 Ma. RS 485 port. MODBUS RTU exchange protocol. Programmable setpoints with a "dry contact" type output.
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod
LB13-18/24K Basket
LB13-18/24K Basket
The height-adjustable bottom allows the tubes to be immersed in the coolant to the required depth. Internal dimensions 255x150x215 mm Weight 1 kg
Produced in: Tomsk
Exhaust cabinet LAB-M SHV ME 150.74.210 F20
Exhaust cabinet LAB-M SHV ME 150.74.210 F20
Furniture for laboratory work. All-metal exhaust cabinet Working surface: FRIDURIT (20 mm) Overall dimensions: Length, mm: 1500 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - metal painted with white powder paint (RAL 9016) guide posts – aluminum profile painted with dark gray powder paint (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP
Saint Petersburg
Produced in: Saint Petersburg
Exhaust cabinet LAB-M SHV 150.74.210 VI
Exhaust cabinet LAB-M SHV 150.74.210 VI
Furniture for laboratory work. Exhaust cabinet made of chipboard Working surface: VITE 16mm Overall dimensions: Length, mm: 1500 Depth, mm: 740 Height, mm: 2100 equipment Working box front anti–spill side - acid–resistant polished stainless steel AISI 316 housing - white chipboard with a thickness of 16mm guide posts – aluminum profile painted with powder paint dark gray (RAL 7011) 2 dependent lifting screens – tempered glass in aluminum frames, lifting 0-710mm, do not change the dimensions of the cabinet when lifting.
LOIP