PKE-A Energy Tester
PKE-A Energy Tester
The devices are designed for: measurements and registration of the main indicators of the quality of electrical energy established by GOST 32144-2013 (GOST R 54149-2010) with registration of protocols according to GOST 33073-2014; measurements and registration of the main parameters of electrical energy in single-phase and three-phase electrical networks (including the effective values of voltages and currents with sinusoidal and distorted curves; active, reactive and full electrical power); measurements of parameters of secondary circuits (load capacity of measuring transformers and voltage drop) in electric energy metering systems and electric energy losses in power supply lines. functional test and verification of connection of meters of active and reactive power and energy, energy measuring converters of voltage, current at the places of their operation; functional test and verification of the connection of single-phase and three-phase electric energy meters without breaking current circuits to detect theft of electricity; measurements of electricity losses in the power supply line. The PKE-A energy tester provides registration with subsequent transfer to a personal computer (PC) of statistical data on the PKE: Values of the PCE according to GOST 30804.4.30 (GOST P 51317.4.30) and GOST 30804.4.7 (GOST P 51317.4.7) with a registration depth of 512 days; Values and durations of voltage dips and overvoltages; Values of the short-term dose of flicker; Parameters of the electrical network and vector diagrams with the depth of registration: - 24 hours for averaging time of 3 s, - 200 days for averaging time of 10 min. The program "Energy Monitoring ES" provides the formation of quality control protocols in the form of GOST 33073-2014.
Marsenergo
Saint Petersburg
Produced in: Saint Petersburg
Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Functional signal generator G6-50
Functional signal generator G6-50
Technical specifications: The waveform is sinusoidal, meander, triangular, sawtooth, (straight, reverse), offset, rectangular (TTL) Frequency range from 0.1 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min The amplitude of the signal is sinusoidal ± 5 V at a load of 600 ohms of the form ± 10 V without load Signal span: meander, triangular, ± 10 V at 600 ohm load sawtooth (forward, reverse) ±20 V without load Limits of output signal level adjustment: -sinusoidal shape from 4 mV to 3.7 V (skz) at a load of 600 ohms from 8 mV to 7.4 V (scz) without load -meander, triangular, sawtooth from 10 mV to 10.465 V (span) at a load of 600 ohms shape: from 20 mV to 20.93 V (span) without load Signal level unevenness ± 5% at frequencies from 0.1 to 10 Hz sinusoidal shape relative to ± 2% at frequencies from 10 Hz to 200 kHz 1 kHz ±5% at frequencies from 200 kHz to 2 MHz The harmonic coefficient of the sinusoidal ± 0.2% at frequencies from 10 to 100 Hz forms ± 0.07% at frequencies from 100 Hz to 10 kHz ±2% at frequencies from 10 to 120 kHz ±1% at frequencies from 120 kHz to 1 MHz ±4% at frequencies from 1 to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns in the frequency range from 0.1 Hz to 2 MHz Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Low-frequency signal generator G3-131A
Low-frequency signal generator G3-131A
Technical specifications: The waveform is sinusoidal, rectangular (TTL) Frequency range from 2 Hz to 2 MHz Frequency setting error ±0.05% Frequency instability ±0.02% in 15 min Signal amplitude ±5 V at 600 ohm load ±10 V without load Limits for adjusting the output signal level from 1 mV to 3.75 V (scr) at a load of 600 ohms from 2 mV to 7.5 V (scz) without load Signal level unevenness ± 2% at frequencies from 20 Hz to 200 kHz relative to 1 kHz ± 5% at frequencies from 200 kHz to 2 MHz Harmonic coefficient ± 0.3% at frequencies from 2 to 20 Hz ± 0.2% at frequencies from 20 Hz to 100 kHz ±1% at frequencies from 100 kHz to 2 MHz Parameters of the rectangular (TTL) signal form log. "1" 3 2.4 V; log. "0" ≤ 0.4 V the duration of the front, the cutoff is not more than 100 ns Operating temperature range from minus 10 °C to + 40 °C Power supply ~230 V, 50 Hz; 10 V×A Dimensions; weight 210×71×255 mm; 2
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-25
Immitance meter E7-25
Technical specifications: Conductivity (Gp) - 10-11 – 10 Cm Resistance (Rs, Rp, Xs, |Z|) 10-5 – 109 Ohms Capacity (Ss, Cp) - 10-15 – 1 F Inductance (Ls, Lp) 10-11 – 104 Gn Dobrotn.(Q), loss angle tangent (tg) 10-4 – 104 Phase shift angle of the resistance set -180° – +180° Leakage current (I) - 10-7 – 10-3 A Measurement error - ± 0.15 % Operating frequencies – 25 Hz – 1 MHz Power consumption - 10 VA Overall dimensions - 225x110x35 mm Weight - 0.8 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
IPPP-1 Semiconductor Device Parameter Meters
IPPP-1 Semiconductor Device Parameter Meters
Technical specifications: 4-channel automated system for measuring the parameters of semiconductors (including test structures on plates) Study of the VAC of 2, 3, 4-pole Parameters of each channel Source/meter:- U: ±2 V, ±30 V (200 mA), ±120 V (±10 mA), I: ±20, ±200 nA, ±2, ±20, ±200 Ma, ±2, ±10mA, (±120V), ±20, ±200 mA (±30V) Source and meter error U, I ± 0.5% Sensitivity of the U/I meter: 10 mv/ 0.1 pA Graphs, tables, texts, databases RS-232C interface, computer software Dimensions, weight: 450x266x444 mm, 23 kg Power supply: ~220V, 120 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Immitance meter E7-30
Immitance meter E7-30
Technical specifications: Wide frequency range 25 Hz–3 MHz Capacity (10-15-1) F Inductance (10-11-104) Gn Resistance (10-5-109) Ohms Conductivity (10-11-10) Cm Modulus of complex resistance (10-5-109) ohms Reactance (10-5-109) Om Phase shift angle -90° – +90° Q factor, loss factor 10-4-104 Leakage current (10-8-10-2) A The error is ±0.1% Offset voltage 0 – 40 V (external up to 120 V) Measuring signal level (0.005 – 1) V RS-232C, USB 2.0 interfaces Mathematical processing of measurements Dimensions, weight: 134x270x320 mm, 4 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk