Search

246 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 88
    Item names
    Loading...
  • 17
    Manufacturer
    Loading...
  • 14
    Made in
  • 17
    Additional
    Loading...
View:
246 products
Connecting device UP-4
Connecting device UP-4
Technical specifications: Residual capacity when working with immitance meters < 1 pF Residual inductance when working with immitance meters < 0.5 µgn Residual resistance when working with immitance meters < 0.05 ohms Maximum input voltage ±60 V Distance between measuring contacts from 0 to 6 mm Length 1050 mm Weight 160 g
MNIPI
Minsk
Produced in: Belarus, Minsk
Rubidium reference generator RRS-002
Rubidium reference generator RRS-002
The device is made in a 19-inch rack design with a 4U stand. The rubidium reference generator RRS-002 provides up to 15 independent signal outputs with a frequency of 10 MHz (5 MHz). The device is designed for long-term uninterrupted operation both in round-the-clock continuous and in session mode. The high reliability of the generator is ensured by reserving the main generator blocks and, in case of malfunction of the active signal source, automatically switching to a backup one.
Ruknar
Nizhny Novgorod
Produced in: Nizhny Novgorod
Power supply C14-100
Power supply C14-100
Operating Mode: Continuous Output stabilized current, A: 1-100 Output voltage, V: 0-14 Power supply: Single-phase mains 220 V; 50 Hz Operating temperature range, °C: +10...+35 Storage temperature, °C: -20...+45 Relative humidity (without condensation), %: 90 Weight, kg: 3.8 Overall dimensions (W x H x D), mm: 225 x 85 x 220
INZHEKT
Saratov
Produced in: Saratov
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
AC voltage calibrator H5-5
AC voltage calibrator H5-5
The calibrator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 (CPC). Technical specifications Ranges of reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 MHz from 3 MV to 3 V - over 100 MHz to 2000 MHz from 30 MV to 3 V Errors in the reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 kHz ± (0.066 – 0.8)% - over 100 kHz to 100 MHz ± (0.85 – 2.5)% - over 100 MHz to 700 MHz ± (1.5 – 12.7)% - over 700 MHz to 2000 MHz ± (4.3 -14.0)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 180 VA Overall dimensions, mm 495x217x411 Weight, not more than 24 kg
Produced in: Moscow
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters Ch3-81, Ch3-81/1
Frequency meters Ch3-81, Ch3-81/1
Designed to measure the frequency or single and averaged period of sinusoidal and pulse signals, as well as to measure the pulse duration and frequency ratio, with a guaranteed measurement error of up to 10-7za year. Description: Ch3-81 (inputs A, B, C) – range 0.1 Hz–2.5 GHz Ch3-81/1 (inputs A, B) – range 0.1 Hz–200 MHz Frequency measurement, frequency ratios Measurement of the period, duration of 1 microsecond–10000 s Signal level 30 mV–10 V (eff.), pulse up to 30 V Thermostated quartz 5 MHz: ±10-7 (year) ±7.5X10-9(day) Frequency temperature departure: ±2.5X10-8 (+5...+40 °C) Number of averaged periods: 1-104 Timestamps 10-7-10-3 s RS-232 interface 8-bit SD indicator Dimensions, weight 80X220X300 mm, 3 kg Power supply: ~ 220V, 20V
MNIPI
Minsk
Produced in: Belarus, Minsk
Electronic milk viscometer "Expert Somatos - 02"
Electronic milk viscometer "Expert Somatos - 02"
from 69 000 ₽
1 supp.
Exclusive benefits: • version with one or two flasks, which allows up to 60 measurements per hour • optionally equipped with an integrated or external printer • * thanks to the new verification method developed from a blank sheet, it can be checked at any standardization and metrology center As a rule, it is used: • Dairy farms — for the timely prevention and treatment of mastitis in cows, which ensures stable supplies of high-grade milk (accordingly increases the cost of products). • Veterinary laboratories, SBBS, points for receiving farm milk from the population to determine the grade and calculate the cost of raw milk. • In the laboratories of milk processing enterprises to control incoming raw milk.
LABORATORIKA
Krasnoobsk
Produced in: Novosibirsk region
PKV-IB-7,2×3,4
PKV-IB-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
IPEP-1 Electrostatic Field Parameter Meter
IPEP-1 Electrostatic Field Parameter Meter
Designed to measure the potentials of electrostatically charged objects, the strength of the electrostatic field and the surface density of electric charges. Technical specifications: Measuring range 0.02-50 kV The error is 5-10% The intensity of the electrostatic field Measuring range 2-1000 kV/m Error 5% Surface density of electric charges Measuring range 0.02-10 µcl/m2 Error 5% Measurement of the electrostatic field strength (2-1000 kV/m) Measurement of the potential of charged objects (0.02–50 kV) Measurement of surface charge density (2x10-8–1x10-5Kl/m2) Measurement error ±(5-10) % Laser pointer of the distance to the object (2, 10 cm) 3.5-digit indicator (LCD with image flip) RS-232C interface Dimensions, weight 40x106x268 mm, 0.7 kg Built-in battery for 8 hours of operation Power supply: ~220, 5 VA, 4.5–5.5 VA battery
MNIPI
Minsk
Produced in: Belarus, Minsk