Search

213 products
View:
  • Selected: 1
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • Areas of use
  • 69
    Item names
    Loading...
  • 15
    Manufacturer
  • 12
    Made in
  • 7
    Additional
View:
213 products
High-voltage test unit UPU-22
High-voltage test unit UPU-22
Technical specifications: Output voltage (DC and AC), 0 - 2 kV; 0 - 5 kV Built-in AC power supply, 10 - 25 A The amplitude value of the DC voltage ripple relative to the set output voltage of 5 kV at idle is not more than ± 5% Error in setting the output voltage, ± 3% Protection tripping current, 101 -- 140 mA Load current of DC and AC output voltage, not less than 1 mA The limit of measuring the resistance of the integrity of the circuit connection, 0, 01 – 0.10 ohms
MNIPI
Minsk
Produced in: Belarus, Minsk
VD-12NFP Eddy Current Flaw Detector with 2 converters
VD-12NFP Eddy Current Flaw Detector with 2 converters
from 292 500 ₽
The device allows you to detect surface defects like cracks, visualizing the signal from the continuity interruptions on the display. The design of the flaw detector allows to determine with high reliability the exact location and depth of defects even on rough surfaces of flat and curved shape, including under a layer of corrosion or in the presence of a protective coating of the controlled area of the product with a thickness of up to 3 mm. The principle of operation of the VD-12NFP eddy current flaw detector: The principle of operation of the VD-12NFP eddy current flaw detector is based on the phenomenon of electromagnetic induction. An alternating magnetic field created in the primary coil of the converter by means of a sinusoidal voltage generator excites eddy currents in the controlled product. A parasitic magnetic field formed by eddy currents at the locations of defects affects the measuring unit (two signal coils connected in series) of the converter, creating an electromotive force in it. The amplitude and phase of the secondary signal carries information about the properties of the defect and the position of the transducer relative to the surface of the controlled product. The output signal from the measuring unit of the converter, after amplification and processing using a microprocessor, is displayed on the readout of the device, and is also stored in the memory block for subsequent transmission to a personal computer. In addition, information about the defects is displayed on a piezoelectric bell used as an audio indicator. Design, features and advantages of the VD-12NFP eddy current control device: The VD-12NFP eddy current flaw detector is a portable device capable of working both in a desktop and in a suspended position in a special bag-case. This ensures convenient operation of the device in a variety of conditions: in the laboratory, in the factory shop or during field tests. The flaw detector consists of an electronic unit with controls and display of test results, as well as three replaceable converters with wear-resistant corundum tips connected to the electronic unit using a connector. The choice of the desired converter depends on the magnetic properties of the material. For the control of parts with grooves, a converter with an inclined tip is offered. The device is powered by 4 AA batteries located in the battery compartment of the electronic unit. The advantages of the flaw detector include: - a screen for visualizing the signal during measurement; - light weight and compact dimensions that allow you to use the device in almost any conditions; - the ability to control the quality of products of various curvature and surface roughness even in the presence of a protective coating or a layer of corrosion; - wear resistance of converters, which is important when monitoring products with increased surface roughness (up to Rz£320); - automatic detection of the type of converter when connected, as well as the presence of built-in memory for storing control results; - the possibility to transfer data to a personal computer for storing or printing control protocols. Scope of application: Portability, high productivity, the ability to work with curved and rough surfaces, as well as the fact that the operation of the flaw detector is practically unaffected by humidity, pressure and contamination of the gas environment or the surface of the controlled product with non-conductive substances ensure the versatility of the device for detecting cracks in various materials. The eddy current flaw detector VD-12NFP is actively used in heavy industry for diagnostics of metal structures, assemblies and mechanisms for various purposes in factory workshops or laboratories, including at enterprises of railway transport, automotive industry, mechanical engineering, pipelines and metal structures. The VD-12NFP flaw detector can be used with equal success in the field, factory workshops, depots, laboratories and workshops to monitor the current condition, as well as to assess the degree of wear, the possibility and duration of further operation of such products made of metals and alloys as over-spring beams, wagon wheels, auto coupler housings, side frames, wheel couples and others. Distinctive features: • control of parts with surface roughness up to Rz320 due to wear-resistant corundum tips; • assessment of the degree of danger (depth) of the defect; • automatic detection of the converter type; • microprocessor control; • 5 universal programs for saving settings; • capable of detecting defects with a depth of 0.3 mm • The angle of deviation of the converter from the normal to the working surface up to 60° • Operating frequency of 70 kHz; • Maximum working clearance of 3mm; • visualization of the signal from the defect; • built-in memory for storing control results • Equipped with a Bluetooth 2.0 wireless communication module, which allows you to transmit control results and control the flaw detector at a distance of up to 20m; • The possibility of forming a control protocol based on the data transmitted to the PC; • Temperature range from 0°C to +40°C; • The design allows you to work with the flaw detector without removing it from the bag-case. Basic kit: Ia5.173.016: 1 electronic unit Ia5.125.031: 1 converter, type 1; marked as (•) Ia5.125.030: 1 converter, type 2; marked as (••) Ia2.706.002: the KOIDZ-VD set of samples with a passport (consisting of: Ia8.896.034: 1 piece; Ia8.896.035: 1 piece; Ia8.896.035-01: 1 piece) - A certificate of verification. 4 AA batteries 1 charger 1 small-sized phone 1 CD with software 1 special key 1 bag-case A calibration certificate is issued for the VD-12NFP flaw detector. 1 passport 1 operating manual 1 calibration instruction
Produced in: Moscow
PKV-IP-7,2×3,4
PKV-IP-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
COMBO FACTOR (VE-meter 50Hz, VE-meter AT-004, E-meter AT-005, P3-34)
from 375 000 ₽
Frequency ranges: from 48 to 52 Hz, from 5 Hz to 400 kHz, from 10 kHz to 30 MHz, from 30 to 300 MHz, from 30 to 50 MHz, from 300 MHz to 18 GHz. three - coordinate antennas; large amount of built-in memory for recording measurement results; high measurement accuracy; the meter is provided with a two-year warranty and manufacturer's service support for the entire service life; wireless Bluetooth communication channel; Control unit and display of measurement results NTM-Terminal. single control unit; the ability to connect multiple meters to one control unit; ergonomic body and comfortable keyboard; high-resolution color display that provides a comfortable presentation of the results; ability to record measurement results; reference base of normative documentation. The meter is adapted to work in the control and analytical complex "NTM-EcoM". the possibility of monitoring the electromagnetic situation at the facilities; storage of measurement results in the NTM-EcoM program archive; analysis of the results obtained for compliance with current regulations; execution of the protocol of instrumental measurements
Produced in: Moscow
AC voltage calibrator H5-5
AC voltage calibrator H5-5
The calibrator is capable of operating both autonomously and as part of automated measuring systems with interfaces such as USB, RS-232, IEEE-488 (CPC). Technical specifications Ranges of reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 MHz from 3 MV to 3 V - over 100 MHz to 2000 MHz from 30 MV to 3 V Errors in the reproduction of alternating electric voltage in the frequency range: - from 10 Hz to 100 kHz ± (0.066 – 0.8)% - over 100 kHz to 100 MHz ± (0.85 – 2.5)% - over 100 MHz to 700 MHz ± (1.5 – 12.7)% - over 700 MHz to 2000 MHz ± (4.3 -14.0)% General characteristics: Operating temperature range from 5 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 180 VA Overall dimensions, mm 495x217x411 Weight, not more than 24 kg
Produced in: Moscow
Immitance Broadband Analyzer E7-29
Immitance Broadband Analyzer E7-29
Technical specifications: Extended frequency range 50 kHz–15 MHz The basic error is ±0.2 % The level of the measuring signal is 40 mV – 1 V s.c . Offset voltage (0 – 40) V The discreteness of the operating frequency setting is 1 Hz Graphical analysis of measured values in a given frequency range USB 2.0 interface -100 C to 400 C; humidity 90% at 300 C Dimensions, weight: 270x134x320 mm, 5 kg Power supply ~230 V, 20 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters Ch3-81, Ch3-81/1
Frequency meters Ch3-81, Ch3-81/1
Designed to measure the frequency or single and averaged period of sinusoidal and pulse signals, as well as to measure the pulse duration and frequency ratio, with a guaranteed measurement error of up to 10-7za year. Description: Ch3-81 (inputs A, B, C) – range 0.1 Hz–2.5 GHz Ch3-81/1 (inputs A, B) – range 0.1 Hz–200 MHz Frequency measurement, frequency ratios Measurement of the period, duration of 1 microsecond–10000 s Signal level 30 mV–10 V (eff.), pulse up to 30 V Thermostated quartz 5 MHz: ±10-7 (year) ±7.5X10-9(day) Frequency temperature departure: ±2.5X10-8 (+5...+40 °C) Number of averaged periods: 1-104 Timestamps 10-7-10-3 s RS-232 interface 8-bit SD indicator Dimensions, weight 80X220X300 mm, 3 kg Power supply: ~ 220V, 20V
MNIPI
Minsk
Produced in: Belarus, Minsk
PKV-IB-7,2×3,4
PKV-IB-7,2×3,4
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Type of coaxial connector (according to GOST RV 51914-2002) IB Frequency range, GHz 25.96-37.50 VSWR 1.35
Produced in: Moscow
COMBI-02M (ASSISTANT, METEOSCOPE-M, TKA-09)
COMBI-02M (ASSISTANT, METEOSCOPE-M, TKA-09)
from 347 000 ₽
A set for measuring sound levels, infrasound, ultra-sound and vibration, measuring microclimatic parameters of the air environment (temperature, humidity, pressure, air velocity), as well as measuring illumination, brightness and pulsation coefficient.
Produced in: Moscow
MI-10X Magnetic Indicator
MI-10X Magnetic Indicator
from 22 500 ₽
Distinctive features. Compactness Autonomy Maximum ease of handling Energy saving mode Technical specifications Indication of induction levels, MT,: weak magnetization 0...2 average magnetization 2...10 strong magnetization more than 10 Power supply 1 accumulator unit or PP3 battery Current consumption, mA, no more than 8 Operating temperature range, °C -30...+50 Dimensions of the electronic unit, mm 90x50x32 Dimensions of the converter, mm 14x50
Produced in: Moscow
PKV-IP-5,2×2,6
PKV-IP-5,2×2,6
Basic properties Wide frequency range; Small VSWR values. Operating conditions Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 5.2×2.6 Type of coaxial connector (according to GOST RV 51914-2002) IP Frequency range, GHz 37.50-50.00 VSWR 1.45
Produced in: Moscow
VD-90NP Eddy current flaw detector in the basic configuration
VD-90NP Eddy current flaw detector in the basic configuration
from 398 250 ₽
The principle of operation of the device: The principle of operation of the flaw detector is based on the excitation of eddy currents in the controlled product and the subsequent release of a signal at the output of the converter, the amplitude and phase of which are determined by the secondary field of eddy currents. Design features and advantages of the VD-90NP flaw detector. The device has a small-sized case, which ensures its lightness, ergonomics and allows you to mount it on your belt or on your arm. The measurement is performed using a remote converter connected by a flexible cable. There are several types of converters for eddy current flaw detection of products made of different materials and different geometries. The large and bright display displays the selected operating modes and measurement results in text and graphic form. The VD-90NP is also characterized by: high sensitivity (it detects cracks starting from 0.1 mm in size); dust–and-moisture-proof housing, which makes it applicable for work in the field; large operating frequency range; maximum working clearance up to 10mm; Bluetooth connection; the ability to control products with high surface roughness, up to Rz320 class; light and sound indication of defect detection; wide operating temperature range from –30°C to +50°C; autonomous low-voltage power supply; long continuous operation time from one set of batteries; compliance with the standard GOST R ISO 15549-2009 (ISO 15549:2008). The use of a microprocessor-based hardware and software platform provide it with the following operational characteristics: automatic adjustment when measuring conditions change, including compensating the influence of the gap; built-in calibration modes; saving the measurement results in the internal memory of the device; a large number of stored programs: sets of parameters and measurement modes, both preset and saved by the user so as to repeatedly monitor the same type of products; The Bluetooth 2.0 wireless communication module allows the device to be used in conjunction with an external laptop or mobile device for remote control, transmission of measurement results for further storage, printing, documentation and analysis. Scope of application: The eddy current method is suitable for non-destructive testing and detection of microcracks in products and parts made of any metals and alloys of complex shape, with high surface roughness, through non-conductive coatings, as well as for checking welded joints. The flaw detector can be used to control parts and assemblies of aviation equipment. The VD-90NP eddy current flaw detector is used for quality control and preventive examination of: - components and parts of rolling stock at railway transport enterprises: wheel sets, auto coupler housings, side frames, spring beams, labyrinth rings, pulleys; - pipes, profiles, rods at rolling mills at the output control, and at the input control of consumers of products; - products made of aluminum and titanium alloys with multilayer coatings at enterprises of the aviation and aerospace industry; - cables, beams, critical components of equipment (cranes, lifts) in construction; - main pipelines in order to detect stress corrosion. A wide range of operating temperatures, dust and moisture protection (IP54 degree of protection), autonomous low-voltage power supply, a long time of continuous operation of the device allows it to be used in the field at low temperatures and under precipitation (rain, snow). Basic kit: • 1 electronic unit for the VD-90NP eddy current flaw detector; • 1 Ia5.125.052 (Type-2) eddy current converter; • 1 converter cable; • 1 charger with batteries; • 1 hand strap; • 1 Ia8.896.104 sample with artificial defects; • 1 Ia8.896.035 coating sample; • 1 storage and carrying case; • 1 documentation set.
Produced in: Moscow