Search

213 products
View:
  • Selected: 1
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 0
    Additional
All filters
  • Areas of use
  • 69
    Item names
    Loading...
  • 15
    Manufacturer
  • 12
    Made in
  • 7
    Additional
View:
213 products
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
Meters of parameters of semiconductor devices IPPP-3, IPPP-3/1
General characteristics: LCD screen 12.1" with a resolution of 1024 x 768, keyboard, mouse. USB, Ethernet. Supply voltage: 230 V / 50 Hz, power: 450 V·A. Operating temperature range: from +5° to +40°C. Dimensions (W x H x D): 470 x 330 x 570 mm, weight: 37 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
PS-78 (waves.)
PS-78 (waves.)
Strobe converters are used as input devices of radio measuring equipment: amplifasometers, frequency meters, spectrum analyzers, circuit analyzers, etc.; in systems of synchronization and frequency stabilization of microwave generators, heterodynes, frequency synthesizers. Basic properties: Wide frequency range; Minimal losses and uneven conversion; High "decoupling" of channels; Large dynamic range of input signals; Harsh operating conditions Operating conditions Operating temperature range from minus 10 to 50 °C; Relative humidity up to 98% at a temperature of 25 ° C. Technical specifications Frequency range: • Microwave signal, GHz 37.5-78.33 • heterodyne, GHz 2.0-6.0 • IF, MHz 0-1000 Conversion losses *>, 30-40 dB by the 20th garm. The power level of the heterodyne, dBm 20-22 Connector type: • Microwave signal input P-waveguide with transitions to 5,2x2,6 and 3,6x1,8 mm • 1HR heterodyne input • IF output two woofer inputs
Produced in: Moscow
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
MULTIFUNCTIONAL MEASURING CONVERTER PARMA T400
Scope of application · measurement of electrical energy parameters in three-phase or single-phase current networks with their subsequent transmission to the upper level of the AIS · the device of the lower level in the AIS at the facilities of generation, conversion, transmission and distribution of electricity
PARMA
Saint Petersburg
Produced in: Saint Petersburg
Universal calibrator H4-201
Universal calibrator H4-201
Technical specifications: reproduction of DC voltage from 50 mv to 1000 V - ranges of 200 mV; 2; 20; 200; 1000 V - error 0.01 – 0.023 % reproduction of the sinusoidal AC voltage from 0.3 mV to 750 V - ranges of 200 mV; 2; 20; 200; 750 V - error 0.15 – 0.225 % - frequency range 20 Hz - 100 kHz (20 Hz - 5 kHz on the range. 200 V; 20 Hz - 2.5 kHz on the range. 750 V) reproduction of DC power from 0.03 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.012 – 0.022 % reproduction of AC power of sinusoidal shape from 3 µA to 50 A - ranges of 200 Ma; 2; 20; 200 mA; 2; 50 A - error 0.062 – 0.23 % - frequency range 20 - 5000 Hz (45 - 1000 Hz on the range. 50 A) RS-232C interfaces; USB operating temperature range from + 5 to +40oC dimensions 184.5x465x540.5 mm weight 20 kg power supply ~ 230 V
MNIPI
Minsk
Produced in: Belarus, Minsk
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk
Produced in: Belarus, Minsk
ELECTRICITY QUALITY RECORDER PARMA RC1.01
ELECTRICITY QUALITY RECORDER PARMA RC1.01
Appointment. Scope of application · continuous monitoring of the 220 V network · identification of problems with power supply in a single apartment, company or HOA · conducting inspections and finding out the source of deterioration in the quality of electricity in apartment buildings, in HOA, in business centers · formation of an expert base when resolving (in court or pre-trial) conflicts between energy marketing organizations and consumers - individuals · justification of the reasons for the failure of expensive household appliances from consumers
PARMA
Saint Petersburg
Produced in: Saint Petersburg
VD-7.2×3.4
VD-7.2×3.4
A flexible waveguide is a piece of high-quality dielectric, which ends with transitions to standard waveguides with flanges. For ease of operation, the waveguide is protected by an elastic shell. Basic properties Manufacturability of the connection; Small losses and VSWR; Economy. Operating conditions Operating temperature range from 5 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical specifications Waveguide cross section, mm 7.2×3.4 Flange type according to GOST RV 51914-2002 Frequency range, GHz 25.95-37.50 VSWR 1.25 Losses, dB 2.0 Length, mm* 500
Produced in: Moscow
ASSISTANT-TOTAL+ (a set of instruments in a plastic case)
ASSISTANT-TOTAL+ (a set of instruments in a plastic case)
from 345 000 ₽
Measurement of sound levels, sound pressure and frequency analysis in the ranges of sound, infrasound and ultrasound, levels of vibration acceleration and frequency analysis in the ranges of general and local vibration on 3 channels simultaneously.
Produced in: Moscow
High-frequency signal generator G4-230
High-frequency signal generator G4-230
The generator is capable of operating both autonomously and as part of automated measuring systems with USB and IEEE-488 (CPC) interfaces. Technical specifications Frequency range from 5 to 17.85 GHz Frequency tuning discreteness 0.001 Hz The main error of the frequency setting is ± 3x10-7 Hz The range of setting the output signal power level at the main output is from minus 110 to 13 dBm The basic error of setting the reference power level is ± 1.0 dB Instability of the output signal power level for any 15-minute time interval of no more than 0.1 dB Metrological characteristics of the generator in the FM operation mode: - frequency range of the modulating signal: low frequency from 1 Hz to 20 kHz RFM from 10 to 100 kHz - frequency deviation setting range (taking into account the carrier frequency value): low frequency from 1 Hz to 100 kHz RFM from 50 to 10000 kHz - the main error of the frequency deviation setting is ± (3 – 18)% Metrological characteristics of the generator in AM operation mode: - frequency range of the modulating signal from 0.05 to 5.0 kHz - the range of setting the amplitude modulation coefficient from 1 to 50 % - the main error in setting the amplitude modulation coefficient: Internal ± (0.15M + 0.2)% External ± (0.20M + 0.5)% Metrological characteristics of the generator in the IM operation mode: - the duration range of modulating pulses from 100 ns to 20 s - the range of the modulating pulse repetition period from 140 ns to 30 s - the difference in the duration of the output RF pulses from the duration of the modulating pulses ± 100 ns Operating temperature range from minus 10 to 40 °C AC power supply 220 V, 50 Hz Power consumption, no more than 150 VA Overall dimensions, mm 498x136x487 Weight, not more than 15 kg
Produced in: Moscow
UCHX2-37
UCHX2-37
Basic properties: Wide frequency range; Sufficiently large output power; High level of suppression of side harmonics of the input signal; Low value of phase noise; Relatively simple technical solutions: - synchronization and frequency stabilization, - stabilization and adjustment of the output power level, - implementation of amplitude and frequency modulation modes; Do not require external bias diodes. Operating conditions: Operating temperature range from minus 10 to 50 ° C; The relative humidity of the air is up to 98% at a temperature of 25 ° C. Technical characteristics Input/output frequency range, GHz 12,93-18,75 / 25,86-37,5 Losses (max.), dB 13 Input power level, dBm 15-21 Unevenness of output power (Rvh. = 20 dBm), dB ± 1.5 The level of parasitic harmonics of the input signal at the output (min.), dBn 20 Output VSWR (max.) 2.0 Connector type: • Input Coax. 3.5/1.5 mm (socket) • Output Waveguide 7.2x3.4 mm Overall dimensions, mm 29x24x24 Weight, g 60
Produced in: Moscow
Verification module PM-9
Verification module PM-9
The composition of the PM-9 calibration module: Universal voltmeter calibrator H4-12 (2 pcs.); Variable voltage calibrator H5-5A; A measure of the stress ratio H4-8; AC voltage voltmeter VK3-78A; Generator-calibrator of harmonic signals SK6-122; The meter-calibrator of the harmonic coefficient SK6-20A; AC power source B2-7 (2 pcs.); The measure of DC electrical resistance is multi-valued MS3070-2; The measure of DC electrical resistance is multi-valued MS3055; Decadal high-resistance resistance magazine M-109R; Single-digit electrical resistance measures MS3080 (0.001; 0.01; 0.1 ohms); Electrical resistance measures unambiguous MS3050M (1, 10, 100, 1000, 10000, 100000 Om); The measure of electrical resistance is unambiguous P4013; The measure of electrical resistance is unambiguous P4023; The measure of electrical resistance is unambiguous P4033; PC, printer; Basic load-bearing structures (BNC). Technical specifications Measuring ranges of electrical quantities: Constant electrical voltage DC from 1 MV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 10 mV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 10 Hz ... 2000 MHz from 10 mV to 100 V Harmonic coefficient in the frequency range of 10 Hz ... 200 kHz from 0.001 to 100 % Ranges of reproduction of electrical quantities: Constant electrical voltage DC from 1 nV to 1000 V AC alternating electric voltage in the frequency range of 10 Hz ... 1 MHz from 3 MV to 1000 V Alternating electric voltage high-frequency VRF in the frequency range of 1 MHz ... 2000 MHz from 3 MV to 3 V DC electric current from 1 µA to 20 A The power of alternating electric current in the frequency range from 0.1 Hz to 10 kHz from 1 µA to 20 A Electrical resistance from 0.001 ohms to 11 ohms Harmonic coefficient in the frequency range from 10 Hz to 200 kHz from 0.001 to 100 % Measurement errors of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage, in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 1.2) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.2 ... 6.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.0008 ... 2.0) % Errors in the reproduction of electrical quantities: Constant electrical voltage DC ± (0.0011 ... 4.0) % AC alternating electric voltage in the frequency range 10 Hz ... 1 MHz ± (0.0055 ... 4.0) % Alternating electric voltage high-frequency VRF in the frequency range 1 MHz ... 2000 MHz ± (0.6 ... 10.0) % DC power ± (0.0033 ... 0.5) % The power of alternating electric current in the frequency range from 10 Hz to 10 kHz ± (0.055 ... 1.0) % Electrical resistance ± (0.001 ... 1.0) % Harmonic coefficient in the frequency range from 10 Hz to 200 kHz ± (0.006 ... 2.0) % General technical characteristics: The area occupied by the module is 6-12 m2 Weight, not more than 430 kg Power supply voltage from 198 to 242 V with a frequency of (50 ± 0.5) Hz Power consumption, no more than 2000 VA
Produced in: Moscow
MF-23IM Flaw detection magnetometer
MF-23IM Flaw detection magnetometer
from 193 200 ₽
The MF-23IM flaw detection magnetometer allows you to determine the compliance of the ratio of the tangential and normal components of the magnetic field strength during magnetic particle testing using both the applied field method (AFM) and the remanent magnetization method (RMM) in accordance with the requirements of current regulatory documentation. The MF-23IM flaw detection magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities.

The flaw detection magnetometer is included in the State Register of Measuring Instruments (GRSI) under No. 20106-00. The magnetometer (milliteslameter) is also included in the register of measuring instruments, testing equipment and measurement methods used at JSC Russian Railways. The flaw detection magnetometer MF-23IM from the manufacturer is used to measure the parameters of constant, variable (industrial frequency) and pulsed magnetic fields when testing ferromagnetic products using the magnetic particle method, as well as to control the level of industrial interference. Specifications.
Magnetic field induction (strength) measurement range: - constant and variable (amplitude and average values) 0.5…1000 mT (4…8000 A/cm) - pulsed (amplitude value) 2…1000 mT (18…8000 A/cm) Indication of measurement results digital or digital + graphic Indicator liquid crystal display Power supply from 1 PP3 battery Current consumption, mA, no more than 15 Memory capacity for storing results 4080 Communication with a computer via infrared channel Dimensions of the electronic unit, mm, no more than 120x60x25 Weight of the electronic unit with battery, g 150

The minimum dimensions of the Hall transducer for the MF-23IM magnetometer make it possible to measure the induction and magnetic field strength in grooves, grooves, corner transitions, i.e. in those areas of the controlled product that are stress concentrators and the most dangerous from the point of view of crack formation; · Measurement of pulsed magnetizing field with pulse duration from 0.5 ms; · Small measurement error (see technical specifications table) · Compact size and low power consumption;

· The magnetometer has 2 modes for displaying measurement results – digital and graphic). The MF-23IM magnetometer in graphical display mode allows you to detect a demagnetizing pulse by displaying its shape and amplitude on a graphic display, as a result of which changes can be made to the magnetization circuit in a timely manner. · The software of the MF-23IM magnetometer allows you to flexibly configure not only the response thresholds, but also the time base, which allows you to tune out false indications caused by reverse emissions of the magnetic field or electromagnetic interference from operating power equipment (magnetizing devices or magnetic particle flaw detectors).

· Determination of the effective magnetization region, within which the tangential component of the magnetic field strength is sufficient for magnetic particle testing, and the ratio of the normal and tangential components of the magnetic field strength is less than or equal to 3. · Checking the mode of magnetization/demagnetization of test objects for compliance with the methodology/technological instructions for magnetic particle testing for a given object.

BASIC SET: Electronic unit Converter 1 Converter 2 Caliber PP3 battery CD with program Case Flaw detection magnetometer MF-23IM. Passport
Produced in: Moscow