Search

449 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 168
    Item names
    Loading...
  • 49
    Manufacturer
    Loading...
  • 30
    Made in
    Loading...
  • 69
    Additional
    Loading...
View:
449 products
Test tube stand "Workplace" 50 hole positions for 0.5 ml test tubes, art. SG‐050‐05
Test tube stand "Workplace" 50 hole positions for 0.5 ml test tubes, art. SG‐050‐05
from 576 ₽
The use of the test tube stand "Workplace" allows you to properly and conveniently organize the space for working with 0.5 ml test tubes. For 0.5 ml test tubes 50 holes: 5 rows of 10 holes Made of plexiglass The conical shape of the holes ensures reliable fixation of the test tubes Rubber feet keep the test tube stand from sliding on benchtop Size 210*100*8
SkyGen
Moscow
Produced in: Moscow
Grand ISP - Inductively coupled plasma mass spectrometer
Grand ISP - Inductively coupled plasma mass spectrometer
The dual-view plasma spectrometer can record any spectral line simultaneously at high resolution in the concentration range from fractions of ppb up to tens of percent and offers a wide range of options for any research task. Designed for the analysis of almost any type of environmental samples – water, soil, precipitation. Quick switching to work. It does not require a long warm-up. Low argon consumption. Easy to use.
Produced in: Novosibirsk
Nitrogen generator GA-400-N
Nitrogen generator GA-400-N
from 432 000 ₽
The GA-400-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-400 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-400, the GA-400-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than 99.5% by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol.(20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati, is not less than 400 l/hour (6.66 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Factory setting of the maximum pressure value in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 35 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Multipurpose X-ray diffractometer DRONE-8 (8H)
Multipurpose X-ray diffractometer DRONE-8 (8H)
The multifunctional X-ray diffractometer DRON-8 (8H) with a vertical theta goniometer and the horizontal position of the sample allows X-ray diffraction analysis of the phase composition, structural state and orientation of a wide range of objects of various shapes and sizes.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
Electronic milk viscometer "Expert Somatos - 01"
Electronic milk viscometer "Expert Somatos - 01"
from 69 000 ₽
1 supp.
Electronic milk viscometer (analyzer of the number of somatic cells in milk) Expert Somatos is a novelty of 2020! Modern, designed taking into account all the wishes of our customers over the past 12 years! The most accurate and most reliable! It fully complies with GOST 23453-2014 (Raw milk. Methods for the determination of somatic cells. Section 6: Method for determining the number of somatic cells using a viscometer) as amended on 01.01.2016, including the length and diameter of the capillary! The analyzer is included in the state register of the Russian Federation as a measuring instrument! Exclusive benefits: • version with one or two flasks, which allows up to 60 measurements per hour • optionally equipped with an integrated or external printer • thanks to the new verification method developed from scratch, it can be trusted in any standardization and metrology center As a rule, it is used: • Dairy farms — for the timely prevention and treatment of mastitis in cows, which ensures stable supplies of high-grade milk (accordingly increases the cost of products). • Veterinary laboratories, SBBS, points for receiving farm milk from the population to determine the grade and calculate the cost of raw milk. • In the laboratories of milk processing enterprises to control incoming raw milk.
LABORATORIKA
Krasnoobsk
Produced in: Novosibirsk region
Energy dispersive sulfur-in-oil analyzer ASE-2
Energy dispersive sulfur-in-oil analyzer ASE-2
The ASE-2 energy dispersive sulfur analyzer is designed to measure the mass fraction of sulfur in unleaded gasoline, diesel fuel, crude oil, kerosene, oil residues, lubricating oil bases, hydraulic oils, jet fuels and other distillate oil products. X-ray radiation from a low-power X-ray tube, converted by a primary radiation filter, excites fluorescence emission from the atoms of the sample being analyzed. The fluxes (primary X-rays scattered on the sample and secondary fluorescence) of radiation fall on a gas proportional counter, whereby the fluorescence radiation of sulfur atoms (SKa) is separated from the radiation with other energies by means of selective filters. The intensity of the fluorescence emission of sulfur atoms registered by the gas proportional counter is proportional to the mass fraction of sulfur in the analyzed sample.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
TA-Lab Voltammetric Analyzer
TA-Lab Voltammetric Analyzer
Automated device for measuring the content of toxic trace elements (As, Cd, Pb, Cu, Zn, Mn, Hg, Se, I, Ni, Co, Fe, Ag, Sb, Bi, Fe, Sn) in water, soil, food products by voltammetric methods with sensitivity at 1/10 of the permissible level (MPC) and below.
Produced in: Tomsk
Small-sized multichannel spectrometer - "Hummingbird-2"
Small-sized multichannel spectrometer - "Hummingbird-2"
The spectrometer was created according to the Cherni-Turner scheme based on a flat diffraction grating and an MAES analyzer with one line of photodetectors. It has increased photometric accuracy due to cooling and temperature stabilization of the photodetector range, as well as due to its shell-less design, in which there is no re-reflection of radiation on the cover glass and the background level in the recorded spectrum decreases. The optical scheme and design of the spectrometer are optimized to obtain a high-quality spectrum with a low level of background radiation in any of the regions lying in the spectral range of 190-1100 nm. The choice of the working area is carried out by changing and rotating the diffraction gratings. The sealed case of the spectrometer is filled with an inert gas. The radiation is injected into the spectrometer using a quartz capacitor or a fiber-optic cable with an SMA-905 connector. The optical scheme and design of the spectrometer are protected by patents.
Produced in: Novosibirsk
Spectrometer SPECTROSCAN MAX-G
Spectrometer SPECTROSCAN MAX-G
The spectrometer is designed to determine the contents of elements in the range from Ca to U in substances in solid, powdery, dissolved states, as well as deposited on the surface or deposited on filters. The principle of operation of the spectrometer is based on irradiation of the sample with primary radiation from an X-ray tube, measurement of the intensity of secondary fluorescent radiation from the sample at wavelengths corresponding to the elements being determined, and subsequent calculation of the mass fraction of these elements according to a pre-constructed calibration characteristic, which is the dependence of the content of the element being determined on the measured intensity. Secondary fluorescent radiation is decomposed into a spectrum using a crystal analyzer. Due to this, the spectrometer has a high resolution, and therefore the ability to accurately analyze complex multicomponent substances.
NPO Spektron
Saint Petersburg
Produced in: Saint Petersburg
ACID-RESISTANT REAGENT CABINET MODELS: LK-600 SHRP, LK-600 SHRP (WITH DRAWERS)
ACID-RESISTANT REAGENT CABINET MODELS: LK-600 SHRP, LK-600 SHRP (WITH DRAWERS)
from 74 850 ₽
The acid-resistant SHRP reagent cabinet is recommended for storing particularly aggressive chemicals, including concentrated acids. It is made of monolithic polypropylene sheet, which is characterized by high chemical resistance. It can be used in conditions of high humidity - there are no parts in the cabinet that are prone to corrosion. 1. LK-600 SHRP Width - 600 POLYPROPYLENE- 69 210 ₽ 2. LK-600 SRP (with drawers) Width- 600 POLYPROPYLENE- 82 730 ₽
SpetsBaltMebel
г. Санкт- Петербург
Produced in: Saint Petersburg
MARK-5010 Hydrogen Purity Analyzer
MARK-5010 Hydrogen Purity Analyzer
High-precision measurements of hydrogen concentration in the range of 95-100% Monitoring of the operation of electrolyzers, control of hydrogen purity in the processes of hydrogen cooling of generators, in the technological processes of chemical, petrochemical, metallurgical and other industries 24 months warranty for deliveries across the Russian Federation A new patented measurement method The device does not require calibration Selectivity of measurement Direct method of measuring molecular hydrogen Insensitivity to humidity, carbon dioxide, oil vapor Measurement time 3-5 min Simple, intuitive interface Minimum maintenance Self-diagnosis Routine maintenance no more than 1 time per year Long-lasting, highly stable sensor The service life of the sensor is at least 10 years Color touch screen
VZOR
Nizhny Novgorod
Produced in: Nizhny Novgorod, Moscow