Search

211 products
View:
  • Selected: 1
    Areas of use
    Loading...
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 0
    Additional
    Loading...
All filters
  • Areas of use
    Loading...
  • 81
    Item names
    Loading...
  • 32
    Manufacturer
    Loading...
  • 18
    Made in
    Loading...
  • 53
    Additional
    Loading...
View:
211 products
IMK-30 Torsion testing machine
IMK-30 Torsion testing machine
Technical specifications: Maximum load (torque): 30 N·m Maximum twisting angle: 50000° The discreteness of the twisting angle: 0.01° Twisting angle error: ±0.1° Torque discreteness: 0.001 N·m Relative error of torque measurement: no more than 1% in the measurement range from 0.6 to 30 Nm Torque measurement error: no more than 0.01 N·m in the measurement range from 0 to 0.6 N · m Maximum rotation speed: 10 rpm Weight: 150 kg Overall dimensions (length x width x height): 1000 x 500 x 500 mm Diameter of the universal testing device: 80 mm Maximum spring length: 300 mm or more
Produced in: Ivanovo
Nanolab based on NTEGRA PRIMA AFM
Nanolab based on NTEGRA PRIMA AFM
Scanning Probe Microscopy In air and in liquid: AFM (contact + semi-contact + non-contact) / Lateral Force Microscopy/ Phase Mapping/ Force Modulation/ Adhesive Force Mapping/ Lithographs: AFM (Power) Only in air: STM/MSM/ESM/SEM/ Kelvin Probe Method/ Display of Spreading Resistance/ AFAM (on demand)/Lithographs: AFM (Current), STM/.
NT-MDT
Zelenograd
Produced in: Moscow, Zelenograd
Scanning probe microscope SMM-2000
Scanning probe microscope SMM-2000
Viewing and measuring grains and defects in the structure of materials, resolution to atoms (Nobel Prize in 1986), replacement of metal-graphic and electron microscopes Increase: from x2 thousand to x10 million. Measuring range: 0.2 nm to 30 microns All basic (STM, contact and vibro-AFM) modes, and more than 25 extras.modes
Produced in: Moscow, Zelenograd
Chromatograph Milichrome A-02
Chromatograph Milichrome A-02
Overall dimensions: 550x230x350 mm Weight (without computer): ~17 kg Power consumption: up to 200 watts Warranty service : 1 year   Detector Two-beam spectrophotometer Spectral range – 190-360 nm Simultaneous detection at 1-8 wavelengths Cell volume – 1.2 µl Noise <0.0001 E.O.P. at 250 nm Drift <0.00005 E.O.P./hour at 250 nm Column Ø2x75 mm stainless steel The efficiency of the column is up to 6000 theoretical plates Thermostat Solid-state electric Set temperature from 35 to 90°C The discreteness of the temperature setting is 1 °C Temperature control error ±0.3°C      Pump Two-pronged, gradient The feed rate is from 5 to 1000 µl/min, the maximum pressure is 70 atm . The gradient is formed from 1 to 20 linear sections Automatic doser Automatic, programmable Number of test tubes – 46 The number of analyses in the series is from 1 to 200 The dosed volume is from 1 to 99 µl Test tubes made of glass with a volume of 200 µl Polyethylene tube stoppers Software OS: Windows® XP/7/10 Milichrome A-02™, Multichrome™, Alphachrome, Alphaspectrum
EkoNova
Novosibirsk
Produced in: Novosibirsk