Search

485 products
View:
  • Selected: 0
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
    Loading...
  • Selected: 1
    Additional
    Loading...
All filters
  • 16
    Areas of use
  • 103
    Item names
    Loading...
  • 31
    Manufacturer
    Loading...
  • 23
    Made in
    Loading...
  • Additional
    Loading...
View:
485 products
Water Bi-distiller BWD-3500F
Water Bi-distiller BWD-3500F
Capacity 3 - 3.5 l/h Dimensions (mm), W x D x H 510 x 465 x 490 Heater 2 x 3.0 kW Cooling water consumption, l/h about 30 — 50 l/h Power supply 230 V ±10%, 50 Hz
Produced in: Belarus, Minsk
Laboratory drying cabinets SHS-14/2,5-C (glass door)
Laboratory drying cabinets SHS-14/2,5-C (glass door)
The electric drying cabinet SHS-14/2.5-C is designed for drying, heating various materials in an air environment at a maximum temperature of 250 ° C. Technical specifications The electric cabinet operates at ambient temperature from 10 to 35 ° C and relative humidity up to 80% at 25 ° C. Operating temperature- 250 ⁰C Power consumption - 1000 watts Dimensions of the working chamber WxDxH- 195x340x195 mm Dimensions WxDxH- 325x600x345 mm Weight - 16 kg
MIUS
Tula
Produced in: Tula
Tip d/dispensers Universal type with filter 100-1000 µl, blue, pack.500 pcs/10000pcs
Tip d/dispensers Universal type with filter 100-1000 µl, blue, pack.500 pcs/10000pcs
from 1 790 ₽
The polymer tip is suitable for most modern dispensers of the Lenpipet,Finpipette, Gilson, Eppendorf, Socorex brands. With filter, non-sterile.
MiniMed
Suponevo
Produced in: Bryansk region
Biosafety cabinet BA-Safe 90
Biosafety cabinet BA-Safe 90
Distinctive features of biological safety cabinet of ODO "BELAKVILON" four versions with different working area widths: 90, 120, 150, 180; ease of operation and ease of operation; highly efficient shadowless diffused panoramic illumination of increased brightness (at least 1500 lux) with brightness adjustment for comfortable operation; a stable air barrier and a constant downward flow in the work area ensures maximum protection of personnel and the sample. These conditions are constantly monitored by automation; the front screen is made of 6 mm tempered glass with 2 handles and a tilt angle of 10°, with 20 cm (available 16– 25 cm) working lifting height; the front working glass has no edge, which allows you to observe the working process without interference; availability of all spare parts in stock (including metal body panels and glass).
Produced in: Belarus, Minsk
Laboratory scales VLE-8201S
Laboratory scales VLE-8201S
from 154 990 ₽
Technical characteristics: NIP, G8200 Discreteness, g0,1 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5g to 5000g incl. ±500; sv. 5000g to 8200g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * ± 300 in the entire range The adjustment weight is built-in The time of setting the readings, s, no more than ~0.7 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-3100
Laboratory scales VLTE-3100
from 67 490 ₽
Technical specifications: NIP, g3100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during primary verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 3100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~3 Weight adjustment 2kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-1100
Laboratory scales VLTE-1100
from 59 990 ₽
Technical specifications: NIP, g1100 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 1100g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Adjustment weight 1kg F2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-8100
Laboratory scales VLTE-8100
from 49 990 ₽
Technical characteristics: NIP, G8100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 8100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Freeze dryer LS-1000
Freeze dryer LS-1000
1 supp.
For vacuum dewatering of pre-frozen substances with condensation of evaporated moisture on a low-temperature condenser, the company "Prointech" offers a new FREEZE DRYER LS-1000. (RF Patent No. 2213916 of 06/18/2011) Characteristic features - the shortest trajectory of vapors - visual inspection of the product - minimum volume to achieve rapid pumping to vacuum - sterilizable stainless steel chamber - compactness, lightness
Prointekh
Pushchino
Produced in: Moscow region, Pushchino
Laboratory scales VLE-6202S
Laboratory scales VLE-6202S
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 6200g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 500g ± 30; sv. 500g ± 50 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Freeze dryer LS-500
Freeze dryer LS-500
1 supp.
• The frozen product is placed in the dryer in stainless steel trays, or in separate containers with a flat bottom up to 105 mm high (test tubes, ampoules, vials, vials, cones, Petri dishes, glass laboratory glasses, etc.). A low-temperature chamber must be provided for freezing the product.  • Drying speed of at least 100 g/h.  • Additional devices: - manifold with vacuum taps for drying from flasks; - centrifuge for drying in ampoules; - collector with taps for sealing ampoules in vacuum; - low temperature trap; • The temperature of the condenser is -50 °C (5 ° C), the capacity is 6 kg of ice.  • The working pressure in the vacuum chamber of the dryer is 6.67 Pa (5•10-2 mmHg), a vacuum pump with a gas ballast device.  • Adjustable shelf temperature from -15°C to +45°C. • Monitoring of vacuum parameters and temperature of the condenser and the product. • Continuous operation time of at least 30 hours. • The dryer is powered by a three-phase 380 V AC mains. The power consumption is 1.3 kW. • External dimensions: 590x660x820 mm, weight 120 kg.
Prointekh
Pushchino
Produced in: Moscow region, Pushchino
Biosafety cabinet BA-Safe 150
Biosafety cabinet BA-Safe 150
Biosafety cabinet Belaquilon BA-safe 150 (for biological protection). The Class II Type A2 biological safety cabinets are designed to reduce the risk of infection to the operator during work with dangerous or potentially dangerous microorganisms and to protect the specimen, is the result of the production of biological safety cabinets based on user feedback. Technical specifications Voltage, frequency, 230V ±10%/Hz Engine 1-phase 230 V, 50 Hz, speed 1150 rpm UV lamp TUV UV lamp, UV lamp timer, 6000 hours of operation Wavelength 254 nm Number of LEDs, pcs at least 380 Lighting power, 55 W Work area illumination at least 1500 lux, brightness adjustable, color of luminous flux 6000 K (cold white light) Internal dimension of the working area, at least 1530×504 mm Working height of front screen elevation, 200 mm Max. height of front screen elevation, 510 mm Frontal screen position alarm Audible position warning. Warning appears on display Outer dimension, mm 1668.5x766.2x1506.6 Height of base, mm 690
Produced in: Belarus, Minsk