Search

61 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 3
    Applying
  • 5
    Names
  • 4
    Manufacturer
  • 6
    Made in
  • Additional
View:
61 products
RUNWAY-32 platform scales
RUNWAY-32 platform scales
from 107 490 ₽
Technical specifications NIP, kg32 Discreteness, g0.5/(0,2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g50 Accuracy class according to GOST OIML R 76-1-2011II is high Limits of error allowed during initial verification, goth 50g to 5 kg incl. ±0.5; sv.5kg to 20kg incl. ±1.0; sv.20kg to 32kg incl.± 1.5 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 10kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-310P-V
Technical laboratory scales VLTE-310P-V
from 47 490 ₽
Technical specifications: NIP, g310 Discreteness, g0,005/(0.002)* Internal calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0,1 The limits of permissible error during initial verification, mgot 0.1g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Weight adjustment is built-in The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-124
Analytical scales VL-124
from 129 990 ₽
Technical characteristics: NIP, G120 Discreteness, g0,0001 External calibration The smallest weighing limit, g0.01 Diameter of the scale bowl, mm91 The price of the verification division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 120g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.0 Adjustment weight 100gE2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-150S
Laboratory scales VLTE-150S
from 67 490 ₽
Technical characteristics: NIP, G150 Discreteness, g0,001 Calibration,self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 150g incl. ±10 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The adjustment weight is built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
RUNWAY-101 platform scales
RUNWAY-101 platform scales
from 114 990 ₽
Technical specifications NIP, kg101 Discreteness, g5/(2)* External calibration The size of the weighing platform, mm350x320 The smallest weighing limit, g500 Accuracy class according to GOST OIML R 76-1-2011II high Limits of error allowed during initial verification, goth 500g to 50 kg incl. ±5.0; sv.50kg to 52kg incl. ±10.0 Dust and moisture protection (IP)54/65 (on request) The setting time, s, no more than ~ 1 - 1.5 Weight adjustment 40kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-410T
Technical laboratory scales VLTE-410T
from 34 990 ₽
Technical characteristics: NIP, G410 Discreteness, g0,01 External calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.2 The limits of the permissible error during the initial verification, mgot 0.2g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 410g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 200gF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-320S
Analytical scales VL-320S
from 214 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, seconds, no more - fast mode - 3; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty Price with VAT, rub214,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLE-6202CI
Laboratory scales VLE-6202CI
from 204 990 ₽
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g1,0 The price of the verification scale division, mg100 The limits of the permissible error during the initial verification, mgot 1g to 5000g incl. ±50; sv. 5000g to 6200g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 30 in the entire range of the adjustment weight built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-310S
Laboratory scales VLTE-310S
from 87 490 ₽
Technical characteristics: NIP, G310 Discreteness, g0,001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Adjustment weight built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg