Search

113 products
View:
  • Selected: 0
    Areas of use
  • Selected: 0
    Item names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
All filters
  • 13
    Areas of use
  • 26
    Item names
    Loading...
  • 7
    Manufacturer
  • 10
    Made in
  • Additional
View:
113 products
Installation for measuring the parameters of the air flow multichannel USPVM
Installation for measuring the parameters of the air flow multichannel USPVM
The installation is intended for use in gas-aerosol emission control systems in order to determine the volumetric air flow in ventilation systems by measuring the linear air flow velocity at local points of the dimensional section, as well as for measuring air temperature and humidity at local points. The measuring system of the installation complies with GOST 12.3.018-79 (SSBT. Ventilation systems. Methods of aerodynamic tests).
Doza
Zelenograd
Produced in: Moscow
Individual gamma and neutron radiation dosimeter DVS-02D
Individual gamma and neutron radiation dosimeter DVS-02D
Purpose: measurement of individual dose equivalent (IED) of mixed gamma-neutron radiation; measurement of individual dose equivalent (IED) of neutron radiation;
Doza
Zelenograd
Produced in: Moscow
Monochromators "LM-3" and "LM-4"
Monochromators "LM-3" and "LM-4"
1 supp.
Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
INSTALLATION OF DOSIMETRIC BETA RADIATION UDB‑AT200
Transmission of units of absorbed dose, directed, individual dose equivalents and their beta radiation power as part of the working standard of absorbed dose (PD) and absorbed dose power (MPD) of beta radiation in a tissue equivalent substance. ▪ Use of closed radionuclide beta radiation sources 90Sr+90Y (BIS-50, 22 GBk), 85Kr (KAC.D3, 15 GBk) and 147Pm (BIP-50, 10 GBk) ▪ Formation of a reference field from sources by a mobile emitter unit using smoothing filters ▪ Source holders with shutter and protective screens ▪ Calibrated length rods and laser device for centering and digitizing ▪ A video surveillance system of readings ▪ The possibility of using an automated extrapolation chamber as part of the installation to reproduce the absorbed dose (absorbed dose rate) of beta radiation in the tissue ▪ Measurement of ionization currents from 1 fA when using an extrapolation chamber and a precision electrometer ▪ Software for installation operation, calibration and calculations ▪ An alarm and blocking system, control of photon radiation levels in the measurement room and operator room
Produced in: Belarus, Minsk
Power injector IP-2
Power injector IP-2
Purpose: provision of connected equipment with constant voltage; conversion of the RS-485 interface to USB (version 01 only) data transmission via the RS-485 interface (version 02 only).
Doza
Zelenograd
Produced in: Moscow
LAMPIX8 Portable instrument for real-time isothermal DNA amplification,  1 channel, 8×0,2 ml
LAMPIX8 Portable instrument for real-time isothermal DNA amplification, 1 channel, 8×0,2 ml
1 supp.
LAMPIX 8 uses the method of Loop-Mediated Isothermal Amplification of DNA and RNA (LAMP and RT-LAMP) for genetic analysis of any kind.
Key features.
  • Compact: supports 8 standard 200μL tubes in a single test run.
  • Portable:provides genetic testing in an on-site or mobile laboratory.
  • Fast: Result within 15 minutes after the start of the analysis.
  • Real-time: Detection of the results with our built-in software.
  • Open system: can work with any test kits with FAM / SYBR dyes for isothermal amplification.
  • Flexible: possibility to adjust settings for your research purposes.
LAMP TEST KITS: LAMP LYME KIT (Detection of the B.burgdorferi in ixodid ticks) *sensitivity from 50 copies of DNA. SARS-CoV-2 test (COVID-19).
Technical Specifications.
  • Excitation source 8 LEDs,
  • Excitation detection 8 photodiodes,
  • Number of Fluorophores 1 FAM/SYBR/EvaGreen,
  • Excitation wavelength 470 nm,
  • Detection range 510-530 nm,
  • Sample capacity 8 х 200 μl tubes,
  • Tube type separate tubes / strips with flat lid,
  • Operating temperature range 37˚C to 75˚C with 0.5˚C resolution,
  • Lid type heated lid,
  • Heated lid temperature range 37.0 ˚C to 75.0 ˚C with 0.5˚C resolution,
  • PC connection USB type С port,
  • Dimensions W × D × H 115 х 80 х 65 mm,
  • Weight 250 g,
  • Power 12 V / 18 W external power supply / power bank,
  • Software Operating system Win 7-10.
    Aivok
    Zelenograd
    Produced in: Moscow, Zelenograd
    Universal reader UZS-01D / UZS-02D
    Universal reader UZS-01D / UZS-02D
    Purpose: to provide bidirectional data exchange with individual dosimeters DKG-05D, DVS-02D.
    Doza
    Zelenograd
    Produced in: Moscow
    Portable flow meter-sampler of gas-aerosol mixtures PVP-06
    Portable flow meter-sampler of gas-aerosol mixtures PVP-06
    Purpose measurement and control of the pumping speed and the total volume of the aerosol mixture pumped through the filters installed on the product during sampling in order to determine the content of aerosol pollutants in the air
    Doza
    Zelenograd
    Produced in: Moscow
    Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
    Flow meter-sampler of radioactive gas-aerosol mixtures "BREEZE"
    Appointment: continuous pumping of atmospheric air with a constant flow rate through a filter element based on Petryanova fabric. measurement of ionizing radiation parameters at a controlled point in accordance with the capabilities of the unit used.
    Doza
    Zelenograd
    Produced in: Moscow
    Spectrometric installation MKG-01D "GARDENER"
    Spectrometric installation MKG-01D "GARDENER"
    The mobile spectrometric installation MKG-01D is designed to measure the energy spectrum of gamma radiation and is used to determine the isotopic composition and specific activity of gamma-emitting radionuclides of radioactive waste (RW) in light-duty containers of various shapes and geometries (metal barrels, plastic containers), in non-returnable protective reinforced concrete containers of the NPC type, as well as to determine activity of extended objects. Purpose: implementation of a fully automated system designed to measure, process and present spectrometric information about the sources of controlled gamma radiation
    Doza
    Zelenograd
    Produced in: Moscow
    Atom Fast 77100 - scintillation radiation detector and application with android
    Atom Fast 77100 - scintillation radiation detector and application with android
    from 45 000 ₽
    1 supp.
    Overall dimensions of the device (mm) 113*25*14 The service life of the built-in battery is at least 300 cycles within the warranty period of the device Full charge time The time to fully charge the built-in battery from a PC USB port or charger is no more than 4 hours. Operating time from a fully charged built-in battery under natural radiation conditions without the use of sound/vibration alarms is at least 2 weeks. Maximum counting speed (imp/sec) is not less than 10,000 imp/s (600,000 imp/min). Device weight (g) no more than 60 Note Atom Fast can withstand irradiation with a dose rate of up to 2000 R/h for 2 s without damage and fully restores functionality after cessation of irradiation in no more than 2 s. Operating temperature range from -40 to +40 degrees. C (for the “new” detection block edition from the fall of 2019, the range is from -20 to +40). When the temperature rises above +40 degrees. C, the device will warn the user about this with the sound of a two-tone siren repeating once a minute. With a further increase in temperature, correct operation of the device is not guaranteed. Energy range of recorded photon radiation (keV) is not less than 60 - 3000. Working size of scintillation detector (mm) 7.5*7.5*100 Contents of delivery USB cable for charging the built-in lithium-ion battery 1 pc. Dosimeter attachment Atom Fast 77100 - 1 pc. Packing box 1 pc. Carrying case - 1 pc.
    Produced in: Moscow, Troitsk