Filter holder FD-1D
Filter holder FD-1D
The filter holder is designed to install an aerosol filter of the AFA type in it. It is used in sampling systems of gas-aerosol media at radiation-hazardous and other production facilities.
Doza
Zelenograd
Produced in: Moscow
Installation radiometric UDGB-01
Installation radiometric UDGB-01
The installation provides continuous measurement, indication on the built-in indicator and transmission over the information network of the value of the volumetric activity of radioactive gases, including tritium and carbon-14. The detection units of the installation can be either built-in or remote. The installation is available in three versions: UDGB-01T, UDGB-1T1, UDGB-01T2, differing in metrological characteristics and design features. Purpose: measurement of the volumetric activity of beta-emitting inert gases (argon, krypton, xenon), as well as gases containing tritium and carbon-14 in the air of working rooms and ventilation systems.
Doza
Zelenograd
Produced in: Moscow
SPECTROMETERS MKS‑AT6104DM, MKS‑AT6104DM1
SPECTROMETERS MKS‑AT6104DM, MKS‑AT6104DM1
Determination of the position of the detection device in space during measurements A cable coil with current transfer Presentation of measurement results in the form of distribution maps of the content of controlled radionuclides or the dose rate of gamma radiation Expert mode for the analysis of the instrument spectrum with automatic identification of the radionuclide composition of the sample GARM expert software for subsequent data processing and analysis, as well as radiation mapping
Produced in: Belarus, Minsk
MKS‑AT6101DR SPECTROMETER
MKS‑AT6101DR SPECTROMETER
- Measurement of pollution density and specific activity of radionuclides 134Cs and 137Cs in soils and soils; - Measurement of the specific activity of radionuclides 137Cs, 134Cs, 131I in water, food, forestry products, agro-industrial complex and liquid radioactive waste; - Determination of the content of natural radionuclides 40K, 226Ra, 232Th; - Identification of radionuclides: 134Cs, 137Cs, 131I, 40K, 226Ra, 232Th; - Measurement of the ambient dose equivalent of gamma radiation Measurements without sampling with GPS-binding Intelligent detection unit in an airtight container Automatic determination of the thickness of the contaminated soil layer by radionuclides 137Cs and 134Cs
Produced in: Belarus, Minsk
LAMPIX8 Portable instrument for real-time isothermal DNA amplification,  1 channel, 8×0,2 ml
LAMPIX8 Portable instrument for real-time isothermal DNA amplification, 1 channel, 8×0,2 ml
1 supp.
LAMPIX 8 uses the method of Loop-Mediated Isothermal Amplification of DNA and RNA (LAMP and RT-LAMP) for genetic analysis of any kind.
Key features.
  • Compact: supports 8 standard 200μL tubes in a single test run.
  • Portable:provides genetic testing in an on-site or mobile laboratory.
  • Fast: Result within 15 minutes after the start of the analysis.
  • Real-time: Detection of the results with our built-in software.
  • Open system: can work with any test kits with FAM / SYBR dyes for isothermal amplification.
  • Flexible: possibility to adjust settings for your research purposes.
LAMP TEST KITS: LAMP LYME KIT (Detection of the B.burgdorferi in ixodid ticks) *sensitivity from 50 copies of DNA. SARS-CoV-2 test (COVID-19).
Technical Specifications.
  • Excitation source 8 LEDs,
  • Excitation detection 8 photodiodes,
  • Number of Fluorophores 1 FAM/SYBR/EvaGreen,
  • Excitation wavelength 470 nm,
  • Detection range 510-530 nm,
  • Sample capacity 8 х 200 μl tubes,
  • Tube type separate tubes / strips with flat lid,
  • Operating temperature range 37˚C to 75˚C with 0.5˚C resolution,
  • Lid type heated lid,
  • Heated lid temperature range 37.0 ˚C to 75.0 ˚C with 0.5˚C resolution,
  • PC connection USB type С port,
  • Dimensions W × D × H 115 х 80 х 65 mm,
  • Weight 250 g,
  • Power 12 V / 18 W external power supply / power bank,
  • Software Operating system Win 7-10.
    Aivok
    Zelenograd
    Produced in: Moscow, Zelenograd
    DRK-1M X-ray Dosimeter
    DRK-1M X-ray Dosimeter
    Purpose determination of the effective dose of patients in radiation diagnostics; control of stability of parameters of X-ray machines
    Doza
    Zelenograd
    Produced in: Moscow
    Droplet separator
    Droplet separator
    The drip collector is designed to remove droplet moisture when sampling air from indoor ventilation systems and is installed in gas aerosol sampling systems. Purpose: removal of droplet moisture from the selected air sample; accumulation of droplet moisture; indication of the level of accumulated moisture; draining the accumulated moisture.
    Doza
    Zelenograd
    Produced in: Moscow
    SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
    SPECTROMETERS MKS‑AT6102, MKS‑AT6102A, MKS‑AT6102B
    Monoblock design Multifunctionality A built-in GPS module Audible, vibration and visual alarms The possibility of connecting external detection units Battery life 25 h (AT6102A,V),18 h (AT6102)
    Produced in: Belarus, Minsk
    Individual gamma radiation dosimeter DKG-05D
    Individual gamma radiation dosimeter DKG-05D
    Purpose: measurement of individual dose equivalent (IED); measurement of the power of the individual dose equivalent (MIED).
    Doza
    Zelenograd
    Produced in: Moscow
    DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
    DOSIMETER‑RADIOMETER ISS‑AT1117M (NEUTRON DOSIMETER)
    Measurement of the power of the ambient dose equivalent and the ambient dose equivalent of neutron radiation, as well as simultaneous monitoring of the power of the ambient dose equivalent and the ambient dose equivalent of gamma radiation. A wide energy range Automatic recording and storage of at least 10,000 GPS-linked measurement results when using BOI4 The possibility of automatic data transfer to a remote server, as well as processing them in export application software when using BOI4 Audible and visual alarm of exceeding threshold levels
    Produced in: Belarus, Minsk
    Monochromators "LM-3" and "LM-4"
    Monochromators "LM-3" and "LM-4"
    1 supp.
    Technical specifications: LM-3 operating range 220-650 nm LM-4 operating range 220-900 nm Diffraction grating (replica) 1200 strokes per millimeter Radius of curvature DR 125 mm The area of maximum energy concentration is 300-400 nm Inverse linear dispersion in the specified spectral range of 6.7 nm/mm Relative opening 1:3.3 The slits are fiber optical fibers with a diameter of 200 microns, stacked in 1 row. The height of the slots is 5 mm The resolution of the monochromator with the specified slits in the ranges of 220-650 nm is not worse than 1.5 nm The resolution of the monochromator with the specified slits in the range of 650-900 nm is not worse than 2.5 nm The accuracy of the wavelength setting is not worse than 0.2 nm Dimensions no more than 205x125x150 mm Weight not more than 3 kg Supply voltage 90-120 / 187-242 V Power consumption not more than 12 W Current frequency 50/60 Hz
    Lumeks
    Saint Petersburg
    Produced in: Saint Petersburg