Voltmeter V7-72
Voltmeter V7-72
Technical specifications: DC voltage Measuring range 2 mv-1000 V Measurement error ± (0.001 - 0.004)% AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.1-8)% Frequency range 10 Hz -1 MHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Support-rotary device OPU-1
Support-rotary device OPU-1
Technical specifications: Azimuth rotation angle from 0° to 360° with vernier ± 15° The angle of rotation according to the angle of the place from minus 30° to plus 90° The angle of the polarization plane is from minus 5° to plus 95° The installation height of the axis of the orientation mechanism is from 1.15 to 2.1 m in the version of USHIAI.301554.001 and from 1.4 to 2.35 m in the version of USHIAI.301554.001-01 Smooth adjustment of the height of the axis of the orientation mechanism 0.15 m In terms of strength under climatic and mechanical influences, the tripod complies with the norms of group 6 GOST 22261-94 The overall dimensions of the tripod are - 2080x2080x2100 mm (USHIAI.301554.001), – 2080x2080x2350 mm (USHIAI.301554.001-01) (shown in the unfolded state at maximum height. The size Ø2080 is the diameter of the circumscribed circle along the vertices of the triangle occupied by the tripod on a horizontal platform) Operating conditions of the tripod: ambient temperature from minus 50 to plus 60oC Tripod weight – 20.5 kg (USHIAI.301554.001), 21.5 kg (USHIAI.301554.001-01)
MNIPI
Minsk
Produced in: Belarus, Minsk
FT-801 IR Fourier spectrometer
FT-801 IR Fourier spectrometer
It is designed for recording absorption spectra of solid, liquid and gaseous substances in the near and middle IR region (including drugs, lacquers and paints, petroleum products, explosives, pharmacological preparations, polymer films and fibers) with their subsequent identification, as well as for qualitative and quantitative analysis of mixtures containing several components.
SIMEKS
Novosibirsk
Produced in: Novosibirsk
Educational laboratory complex KUL-1
Educational laboratory complex KUL-1
It is intended for use in higher and secondary educational institutions during laboratory workshops on training specialists in engineering and technical specialties and natural science disciplines. Technical specifications: Upost.- 0.1 mV - 500 V; Uperem.- 1 mV-300 V (40 Hz-20 kHz) Ippost. - 0.1 mkA- 2 A; Iperem. - 1.0 mkA - 2 A (40 Hz-1 kHz) Rpost. - 0.1 Ohm – 20 mOhm Generation of triangles, pilobr., "meander", sinusoid. signal in the frequency range 0.1 Hz – 1 MHz Frequency measurement in the range of 0.1 Hz – 1 MHz The form of the measured signals is sine, pulse Constant voltage: at a current of 1 A - + 5 V at a current of 0.5 A for each channel - ± 12 V Adjustable Uppost. at a current of up to 1 A - 0 – 30 V Dimensions - 170x340x380 mm Power supply – 230 V, 50 Hz, 200 VA - max. Weight – 8.0 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory scales VLE-6202S
Laboratory scales VLE-6202S
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g0.5 The price of the verification scale division, mg100 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 6200g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The actual typical error limits of the scales, mg * up to 500g ± 30; sv. 500g ± 50 The adjustment weight is built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Analytical scales VL-84V
Analytical scales VL-84V
from 184 990 ₽
Technical characteristics: NIP, G82 Discreteness, g0,0001 Internal calibration The smallest weighing limit, g0.01 The diameter of the scale bowl, mm91 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 82g incl. ± 1.0 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more - fast mode - 2; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x213x338 Weight of the scales, kg, not more than 6.2 The adjustment weight is built-in 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 77 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
AF011B Microassembly
AF011B Microassembly
A high-speed signal limiter amplifier. Designed for use in electronic counting frequency meters. Description: The magnitude of the input signals for selecting the switch input and inverting the signal of the limiter amplifier at a supply voltage of ± 5 V: - logical "0" not more than 0.2 V; - logical "1" at least 4.8 V. The value of the input signals of switching on / off the switch at a supply voltage of ± 5 V: - logical "0" no more than 3.3 V; - logical "1" at least 4.1 V. The magnitude of the output signals of the switch at a supply voltage of ± 5 V and a load of 300 ohms connected to zero potential: - logical "0" from 3.1 V to 3.4 V; - logical "1" from 4.0 V to 4.3 V. The minimum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz should be no more than 30 mV. The maximum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz must be at least 1 V. The value of the supply voltage: - positive 5±0.2 V; - negative -5±0.2 V. The current consumption should be no more than: - from a positive power source 110 mA; - from a negative power supply 35 mA.
MNIPI
Minsk
Produced in: Belarus, Minsk
Hygrometer-thermometer digital GTC-2
Hygrometer-thermometer digital GTC-2
It is designed to measure relative humidity and air temperature in industrial, warehouse and residential premises, in climatic chambers and technological highways, in open areas (weather stations). Technical specifications: Measurement of relative humidity measuring range (10-100) % resolution 0.1% basic measurement error ± 3% Temperature measurement measuring range (-60 ... +300) ° C resolution 0.1 °C measurement error ± (0.5 - 1.5) ° C Power supply network adapter, built-in battery USB 2.0 interface Weight 1.5 kg The verification interval is 1 year
MNIPI
Minsk
Produced in: Belarus, Minsk
TA-Lab Voltammetric Analyzer
TA-Lab Voltammetric Analyzer
Automated device for measuring the content of toxic trace elements (As, Cd, Pb, Cu, Zn, Mn, Hg, Se, I, Ni, Co, Fe, Ag, Sb, Bi, Fe, Sn) in water, soil, food products by voltammetric methods with sensitivity at 1/10 of the permissible level (MPC) and below.
Produced in: Tomsk
Analytical scales VL-220C
Analytical scales VL-220C
from 194 990 ₽
Technical specifications: PV, g220 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the verification division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 220g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.3 in the entire range The time of setting the readings, seconds, no more-fast mode - 3; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 Adjustment weight built 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Digital oscilloscope S8-52
Digital oscilloscope S8-52
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 120 MHz. Technical specifications: Number of channels 2 120 MHz bandwidth Sampling rate 250 MHz Equivalent sampling rate of 10 GHz Rise time of PH <= 2.9 ns Input active resistance (1±0.02) Mom Input capacitance <= 25 pF 120 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 250 Mbps, in real time Recording length up to 16K counts in each channel Color LCD screen with LED backlight Cursor and automatic measurements USB and RS-232 interface
MNIPI
Minsk