Search

149 products
View:
  • Selected: 0
    Applying
    Loading...
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
    Loading...
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 22
    Applying
    Loading...
  • 59
    Names
    Loading...
  • 18
    Manufacturer
    Loading...
  • 15
    Made in
  • Additional
    Loading...
View:
149 products
Flame Ionization (PID) for chromatograph
Flame Ionization (PID) for chromatograph
The most common, universal detector that is suitable for the analysis of a wide range of organic compounds. The sensitivity depends mainly on the number of carbon atoms. In combination with a methanator, it allows the analysis of carbon oxides at the level of 0.1 Rt. The level of fluctuation noise is up to 50 MV, the maximum signal is up to 2500 V. Technical characteristic: 1.2*10712 gs/s for hydrocarbons
Produced in: Yoshkar-Ola, Mari El
Digital oscilloscope C8-43
Digital oscilloscope C8-43
It is designed to study periodic signals in the frequency band 0-50 MHz and single electrical signals by registering them in digital memory with a sampling frequency of up to 50 MHz, observing their shape on a liquid crystal display (LCD), measuring the amplitude and time parameters of the signal under study. Description: 2 mV...10 V/div; 10 ns...100 s/del ADC: 2 channels, 100 MHz, 8 bits, 64 KB/channel Equivalent sampling rate of 10 GHz Marker measurements U: ±2.5%,T: ±1.5% Pre-start, averaging,filtering Familiar management interface High-quality, "live" image Additional modes in the "MENU" Low price Screen 80x100 mm (CRT made in Holland) Dimensions, weight: 120x300x380 mm, 7 kg Power supply: ~220V, 80 VA
MNIPI
Minsk
Produced in: Belarus, Minsk
Measuring antenna P6-61
Measuring antenna P6-61
Technical specifications: Frequency range (26.0 - 300) MHz SWR < 2 The limit of permissible error of the antenna coefficient, not more than ± 2.0 dB Orthogonal polarization signal level -20 dB Ambient air temperature from - 50 to + 60 Relative humidity of 95 % at + 35 ° C Overall dimensions (HxWxD) 145x75x1720 mm Weight 0.7 kg
MNIPI
Minsk
Produced in: Belarus, Minsk
Energy dispersive sulfur-in-oil analyzer ASE-2
Energy dispersive sulfur-in-oil analyzer ASE-2
The ASE-2 energy dispersive sulfur analyzer is designed to measure the mass fraction of sulfur in unleaded gasoline, diesel fuel, crude oil, kerosene, oil residues, lubricating oil bases, hydraulic oils, jet fuels and other distillate oil products. X-ray radiation from a low-power X-ray tube, converted by a primary radiation filter, excites fluorescence emission from the atoms of the sample being analyzed. The fluxes (primary X-rays scattered on the sample and secondary fluorescence) of radiation fall on a gas proportional counter, whereby the fluorescence radiation of sulfur atoms (SKa) is separated from the radiation with other energies by means of selective filters. The intensity of the fluorescence emission of sulfur atoms registered by the gas proportional counter is proportional to the mass fraction of sulfur in the analyzed sample.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
ION-3701 Version "North"
ION-3701 Version "North"
from 77 245 ₽
A small-sized digital magnetometer (gaussmeter, teslameter), a residual magnetization meter ION-3701 version "North" is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in adverse climates, conditions of negative temperatures, the Far North and etc . It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
 Electronic Stopwatch-Meter IVPR-203M
Electronic Stopwatch-Meter IVPR-203M
from 40 940 ₽
The electronic stopwatch - time parameter meter IVPR-203M is a universal shield device of a new type for monitoring and measuring the time parameters of relays, switches and switches of electrical equipment, relay protection, automation and telemechanics.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
Technical laboratory scales VLTE-2100T
Technical laboratory scales VLTE-2100T
from 27 490 ₽
Technical characteristics: NIP, G2100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5 The limits of permissible error during primary verification, mgot 0.5g to 500 g incl. ±50; sv. 500g to 2000g incl. ±100; sv. 2000g to 2100g incl. ±150 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high Weight adjustment 2KGF2* The time of setting the readings, s, no more than ~ 1 - 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Fischer coulometric Titrator
Fischer coulometric Titrator
from 690 000 ₽
The Fischer titrator is designed to measure the moisture content in non-aqueous media in substances that do not interact with the Fischer reagent, such as petroleum, petroleum products, oils (transformer, turbine, hydraulic, motor, etc.), organic solvents, etc. in accordance with GOST ISO 12937:2000, GOST 24614-81, GOST 33733-2016, GOST R 54284-2010, GOST R IEC 60814, GOST 14870-77, ASTM D 4928-00 (2010), ASTM D6304-07, ASTM D 1533-00, ASTM E 1064-05.
EKROSKHIM
Saint Petersburg
Produced in: Saint Petersburg
Mercury Monitor type RA-915AM for Natural Gas Analysis
Mercury Monitor type RA-915AM for Natural Gas Analysis
1 supp.
Technical specifications: Absorption coefficient of mercury vapor by the built-in sorption filter, %, not less than 98 Volume flow rate of the analyzed gas at the monitor inlet, dm3/min, not less than 4 Monitor power supply from AC mains: voltage, V frequency, Hz 220 ± 22 50 ± 1 Power consumption, In × A, not more than 150 Overall dimensions (LXC), mm, no more 665x482x222 Weight, kg, not more than 25 Operating conditions: - ambient temperature, °C from 10 to 35 - relative humidity (at 25 °C), %, not more than 80 - atmospheric pressure, kPa from 84 to 106.7 - relative humidity of the analyzed gas (at 20 °C), %, not more than 99 Average time to failure, h 12000 Average service life, 5 years
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Voltmeters B7-91, B7-91/1
Voltmeters B7-91, B7-91/1
Technical specifications: DC voltage , Measuring range, 10 MV - 1000 V Measurement error, ± 0.03% AC voltage , Measuring range, 1 mV - 750 V Measurement error, ± 0.4% Frequency range, 20 Hz- 100 kHz Direct current , Measuring range, 1 mkA - 2 A (B7-91/1) Measuring range, 1 mkA - 20 A (B7-91) Measurement error, ± 0.03%
MNIPI
Minsk
Produced in: Belarus, Minsk
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
X-ray fluorescence wavelength dispersive flowstream pulp, suspension and solution analyzer AR-35
The AP-35 analyzer is a fully automated analytical complex designed for continuous X-ray fluorescence analysis of the chemical composition of slurries and solutions in flow. The instrument has a movable software-controlled measuring head with an X-ray tube and fixed spectrometric channels (up to 8), each of which can be set up for any chemical element (from Ca to U). In operation, up to 15 flow cells are measured by the head according to a preset program. Multi channel capability (up to 15 products to be measured). Compatibility with automation systems for sampling, sample delivery, data handling and presentation, data archiving. Link to factory process control system High expressiveness, high analytical precision, low detection limits, reproducibility High reliability. The principle of operation is based on the excited fluorescence produced by the atoms of the material under analysis through the radiation of an X-ray tube. The fluorescence radiation of a particular chemical element is picked up by the crystal analyzer, and then the radiation at a specific wavelength is detected by an X-ray tube detector. The intensity of the recorded fluorescence radiation of a certain wavelength is directly proportional to the mass fraction of the chemical element in the substance under study.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
MF-23IM Flaw detection magnetometer
MF-23IM Flaw detection magnetometer
from 168 000 ₽
The MF-23IM flaw detection magnetometer allows you to determine the compliance of the ratio of the tangential and normal components of the magnetic field strength during magnetic particle testing using both the applied field method (AFM) and the remanent magnetization method (RMM) in accordance with the requirements of current regulatory documentation. The MF-23IM flaw detection magnetometer meets the requirements in the field of non-destructive testing for the main industries: nuclear, energy, oil and gas complex, general and special engineering, railway transport, aerospace industry, elevator and crane facilities.

The flaw detection magnetometer is included in the State Register of Measuring Instruments (GRSI) under No. 20106-00. The magnetometer (milliteslameter) is also included in the register of measuring instruments, testing equipment and measurement methods used at JSC Russian Railways. The flaw detection magnetometer MF-23IM from the manufacturer is used to measure the parameters of constant, variable (industrial frequency) and pulsed magnetic fields when testing ferromagnetic products using the magnetic particle method, as well as to control the level of industrial interference. Specifications.
Magnetic field induction (strength) measurement range: - constant and variable (amplitude and average values) 0.5…1000 mT (4…8000 A/cm) - pulsed (amplitude value) 2…1000 mT (18…8000 A/cm) Indication of measurement results digital or digital + graphic Indicator liquid crystal display Power supply from 1 PP3 battery Current consumption, mA, no more than 15 Memory capacity for storing results 4080 Communication with a computer via infrared channel Dimensions of the electronic unit, mm, no more than 120x60x25 Weight of the electronic unit with battery, g 150

The minimum dimensions of the Hall transducer for the MF-23IM magnetometer make it possible to measure the induction and magnetic field strength in grooves, grooves, corner transitions, i.e. in those areas of the controlled product that are stress concentrators and the most dangerous from the point of view of crack formation; · Measurement of pulsed magnetizing field with pulse duration from 0.5 ms; · Small measurement error (see technical specifications table) · Compact size and low power consumption;

· The magnetometer has 2 modes for displaying measurement results – digital and graphic). The MF-23IM magnetometer in graphical display mode allows you to detect a demagnetizing pulse by displaying its shape and amplitude on a graphic display, as a result of which changes can be made to the magnetization circuit in a timely manner. · The software of the MF-23IM magnetometer allows you to flexibly configure not only the response thresholds, but also the time base, which allows you to tune out false indications caused by reverse emissions of the magnetic field or electromagnetic interference from operating power equipment (magnetizing devices or magnetic particle flaw detectors).

· Determination of the effective magnetization region, within which the tangential component of the magnetic field strength is sufficient for magnetic particle testing, and the ratio of the normal and tangential components of the magnetic field strength is less than or equal to 3. · Checking the mode of magnetization/demagnetization of test objects for compliance with the methodology/technological instructions for magnetic particle testing for a given object.

BASIC SET: Electronic unit Converter 1 Converter 2 Caliber PP3 battery CD with program Case Flaw detection magnetometer MF-23IM. Passport
Produced in: Moscow