Analytical scales VL-320S
Analytical scales VL-320S
from 214 990 ₽
Technical characteristics: NIP, G320 Discreteness, g0,0001 Calibration,self-calibration Diameter of the scale bowl, mm80 The smallest weighing limit, g0.01 The price of the calibration division, mg1 The limits of permissible error in the weighing intervals during verification, mgot 0.01g to 50g incl. ± 0.5; sv. 50g to 200g incl. ± 1.0; sv. 200g to 320g incl. ± 1.5 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 0.45 in the entire range The time of setting the readings, seconds, no more - fast mode - 3; - standard mode - 6 Overall dimensions of the scales (LxWxH), mm356x220x338 Weight of the scales, kg, no more than 7,6 The adjustment weight is built-in 7 years warranty Price with VAT, rub214,990
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Flame Photometric(FD)
Flame Photometric(FD)
Selective detector for phosphorus and organosulphide compounds. It is used mainly for the analysis of sulfur-containing substances (hydrogen sulfide, mercaptans, thiophenes, etc.). The sensitivity for sulfur reaches 0.1. ppm. In addition, PFD has sufficient sensitivity and selectivity to compounds containing nitrogen, boron, tin, chromium, selenium, germanium, as well as CO, POPS, MgOx, $02, Ma, NOT C52. The selectivity of 5-containing compounds to hydrocarbons is 105. Technical characteristic: 8,0*10-13 g5/s by sulfur 1.0*10`13 g/s for phosphorus
Produced in: Yoshkar-Ola, Mari El
Voltmeters V7-65, V7-65/1, V7-65/2
Voltmeters V7-65, V7-65/1, V7-65/2
Technical specifications: Measuring range 20 mv-1000 V Measurement error ± (0.03% +5 E.M.R.) AC voltage Measuring range 1 mV - 700 V Measurement error ± (0.3% +200 E.M.R. - 4% +800 E.M.R.) Frequency range 20 Hz-100 kHz Direct current Measuring range 1 mA - 2 A Measurement error ± (0.12% +10 E.M.R.) Alternating current Measuring range 10 mA - 2 A Measurement error ± (0.6% +300 E.M.R.) Frequency range 20 Hz - 5 kHz
MNIPI
Minsk
Produced in: Belarus, Minsk
Installation for measuring radio technical characteristics of dielectric materials
Installation for measuring radio technical characteristics of dielectric materials
Designed for: measurements of the relative permittivity and the tangent of the dielectric loss angle of materials at a frequency of 9 GHz in accordance with GOST R 8.623-2015 "GSI.
VNIIFTRI
Mendeleevo
Produced in: Mendeleevo, Moscow region
Laboratory scales VLE-6202CI
Laboratory scales VLE-6202CI
from 204 990 ₽
Technical characteristics: NIP, G6200 Discreteness, g0,01 Calibration,self-calibration The size of the scale bowl / platform, mm170x180 The smallest weighing limit, g1,0 The price of the verification scale division, mg100 The limits of the permissible error during the initial verification, mgot 1g to 5000g incl. ±50; sv. 5000g to 6200g incl. ±100 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011I special The actual typical error limits of the scales, mg * ± 30 in the entire range of the adjustment weight built-in The time of setting the readings, s, no more than ~ 1.5 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
CRYSTAL-2000 CHROMATOGRAPH
CRYSTAL-2000 CHROMATOGRAPH
Technical characteristics: DETECTOR - TYPE OF CHROMATOGRAPH - DETECTION LIMIT, G/S (G/ML) -STANDARD DEVIATION, % - LEVEL OF FLUCTUATIONAL NOISES, A (V) -DRIFT, А/H (V/H) FID Crystall-2000 5×10⁻¹² 2 2×10⁻¹⁴ 4×10 ⁻¹³ TCD Crystall-2000 (5×10⁻⁹) 2 (2×10⁻⁷) (2×10⁻⁵) ADC Crystall-2000 5×10⁻¹⁴ 4 1×10⁻¹² 8×10⁻¹¹ FPD-Р Crystall-2000 2×10⁻¹² 6 2×10⁻¹¹ 4×10⁻¹⁰ FPD-S Crystall-2000 2×10⁻¹¹ 10 2×10⁻¹¹ 4×10⁻¹⁰
Produced in: Yoshkar-Ola, Mari El
Digital oscilloscopes S8-54
Digital oscilloscopes S8-54
Designed to study and measure the parameters of electrical signals in the frequency band from 0 to 200 MHz. Description: 200 MHz bandwidth 2 channels, external synchronization input Vertical sensitivity 2 mV/div Sampling rate up to 400 Mbps, in real time Color LCD screen with LED backlight Saving signals on external media in graphic and text form Cursor measurements and 22 types of digital measurements USB and Ethernet interface Frequency meter function Logger function.
MNIPI
Minsk
Produced in: Belarus, Minsk
Frequency meters H3-96
Frequency meters H3-96
Designed for measuring the frequency and period of sinusoidal and pulse signals, measuring pulse duration, time intervals, pulse duty cycle, frequency ratio of electrical signals, counting the number of pulses, output of reference frequency signals. Technical specifications: Input to (sinusoidal signal) - range 100 - 3200 MHz Input A, C (sine, pulse) - range 0.01 - 200 MHz The number of averages. the period of the input signal is 1 ... 105 Borehole measurement by inputs – 1.000001- 999999999 Frequency ratio in channels: A/S, C/A, B/C and B/A - up to 999999999 Quartz thermostatic generator The nominal frequency value is 5 MHz Error: ± 2•10-8 - in 30 days, ± 5•10-8 - in 12 months Overall dimensions (HXHL) - 345x285x106 mm Weight: 4 kg Reference generator: ±5x10-8 for 12 months. Operating conditions: - 10° C ... +50° C
MNIPI
Minsk
Produced in: Belarus, Minsk
Laboratory scales VLTE-310S
Laboratory scales VLTE-310S
from 87 490 ₽
Technical characteristics: NIP, G310 Discreteness, g0,001 Calibration, self-calibration The size of the scale bowl / platform, mm116 The smallest weighing limit, g0.02 The price of the verification scale division, mg10 The limits of the permissible error during the initial verification, mgot 0.02g to 50 g incl. ±5; sv. 50g to 200g incl. ±10; sv. 200g to 310g incl. ±15 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II high Adjustment weight built-in The time of setting the readings, s, no more than ~3 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Liquid analyzer "FLUORAT®-02-4M"
Liquid analyzer "FLUORAT®-02-4M"
1 supp.
Technical specifications: Limit of detection of the control substance (phenol) in water, mg/dm3, not more than 0.005 Measurement range of the mass concentration of the control substance (phenol) in water, mg / dm3 from 0.01 to 25 Measurement range of the directional transmission coefficient, % from 5 to 100 Limits of permissible absolute error of measurements of the directional transmission coefficient, % ±2 Warm-up time, min, not more than 30 Continuous operation time, h, not less than 8 Overall dimensions, mm, no more than 305x320x110 Weight, kg, not more than 6.5 AC power supply: - AC power supply voltage, V - frequency, Hz (220 ±22) (50 ±1) Power consumption, V× A, no more than 36 Operating time for failure, h, no less than 2500
Lumeks
Saint Petersburg
Produced in: Saint Petersburg
Infrared analyzer INFRASKAN 4200
Infrared analyzer INFRASKAN 4200
1 supp.
The INFRASKAN 4200 analyzer has been tested at the D.I. Mendeleev VNIIM, entered into the unified State Register of measuring instruments under No. 83050-21. All manufactured devices undergo primary verification and have the appropriate certificate. Analyzes a wide range of quality indicators (protein, moisture, quantity and quality of gluten (IDC), fat/oil content, water absorption capacity, acid number, peroxide number, m.d. phosphorizing substances, etc.) Is calibrated to assess moisture and protein in whole grains (wheat, barley). The cuvette compartment for the analysis of bulk, liquid and pasty products allows to analyse liquid vegetable oils without the use of additional devices. The built-in whiteness module allows to determine the whiteness of the product simultaneously with other quality indicators (moisture, protein, amount of gluten). A wide spectral range (400-2500nm) provides measurement of the zonal reflection coefficient to determine the whiteness of flour in accordance with the GOST 26361-2013 methodology. It is possible to calculate the amino acid composition of feed components. To organize the work of analyzers in the ECANET network, the INFRASCAN-4200 analyzer can be used as a server for storing and transmitting data. The remote access mode allows to remotely update existing calibrations, install additional calibration models and develop new calibration models for new products, as well as make adjustments to technical settings if necessary.
GK EKAN
Saint Petersburg
Produced in: Saint Petersburg
Software and hardware complex with a set of sensors for physics classrooms
Software and hardware complex with a set of sensors for physics classrooms
The software and hardware complex with a set of sensors for physics classrooms is designed to measure physical quantities during demonstration work on various sections of physics, as well as to perform experimental work on physics. The set of units of the measuring system is compatible with a PC, has software with an instruction manual. The sensor kit includes 10 sensors for measuring the following physical quantities: - temperature sensor DTV-1 (measuring range -200C + 1100 S); - air humidity sensor DTV-1 (measuring range 10-100%); - pressure sensor DD-1 (measuring range 0-700 kPa); - acceleration sensor DUIMP-1 (measuring range - 4 – + 4 g); - permanent magnetic field induction sensor DUIMP-1 (- 8 – + 8 Gs); - illumination sensor DSCH-1 (measuring range 1 -60 000 lux); - distance sensor DR-1 (measuring range 0.04 – 4.0 m); - angular velocity sensor DUPUS-1 (remote) (measuring range 0 – 210 0/ c); - rotation angle sensor DUPUS-1 (measuring range ±3600); - flame temperature sensor DTP-1 (measuring range 100 – 11000 S).
MNIPI
Minsk