Laboratory scales VLTE-8100
Laboratory scales VLTE-8100
from 49 990 ₽
Technical characteristics: NIP, G8100 Discreteness, g0,1 External calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g5,0 The price of the verification scale division, mg1000 Limits of permissible error during primary verification, mgot 5.0g to 5000g incl. ± 500; sv. 5000g to 8100g incl. ±1000 in accordance with GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The time of setting the readings, s, no more than ~2 Weight adjustment 5kgF2* 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Microassembly RB1S8KN009
Microassembly RB1S8KN009
Two-channel analog switch with signal summation function Designed for use in oscilloscopes with a bandwidth up to 350 MHz. Technical specifications: The value of the voltage between the outputs of the switch at load resistance RN = (50 ± 2.5) ohms and opening voltages UU1 = (2.0 ± 0.2) V and locking UU2 = (4.2 ± 0.2) V channels supplied alternately to the corresponding inputs (start 1, start 2) of the switches must be: in the absence of an input signal from minus 0.1 to plus 0.1 V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of the open channel (0.45 ± 0.1) V with an input signal UC = (0.3 ± 0.05) V supplied to one of the inputs of both open channels (0.45 ± 0.1) V
MNIPI
Minsk
Produced in: Belarus, Minsk
MS-10 Magnetic Structuroscope
MS-10 Magnetic Structuroscope
from 310 500 ₽
Distinctive features: - Non-destructive testing of strength, plasticity and viscosity of parts and structures made of ferromagnetic steels and cast iron according to the following standards: GOST 30415-96, OST 14-1-184-65, TU-14-1016-74 - Non-destructive testing of the depth and hardness of surface-hardened layers on steel and cast iron parts; - Quality control of low-temperature tempering of cutting and measuring tools, bearing steels; - Control of uniaxial elastic stresses; - Control of the uniformity of the properties of massive parts. Technical specifications: The range of coercive force of the material of the controlled products, A/cm, is 1.0...60. The limit of the permissible basic absolute error of measurements of the coercive force (Ns) on standard samples at a normal ambient temperature of 20 ± 5°C does not exceed the values of 0.1+0.04 Ns (Ns stands for the measured value of the coercive force of the standard sample). This error probability is provided with a gap between the converter and the surface of the controlled product not exceeding 0.5 mm. Basic version: The structroscope is powered by a battery. Extended version: It is possible to work on 220V/50Hz grid. The time of setting the operating mode after power on, min: no more than 2 Time of one measurement, sec: no more than 6 Continuous operation time (without recharging), h: at least 16 Internal memory: up to 512 series of 512 measurements each with the possibility to view the results Operating temperature range: -20°C to +40°C; Overall dimensions, (length x width x thickness), mm: electronic unit: 190x140x80 converter: 135x75x100 Weight, kg: the electronic unit with a battery: 2.3 ± 0.05 the converter: 1.3± 0.05 Basic version kit: Ia5.173.023 Electronic unit: 1 pc. Ia5.125.061 Converter: 1 pc. Ia8.896.121 Control sample of coercive force (plate PN-1): 1 pc. Ia8.896.122 Control sample of coercive force (plate PN-2): 1 pc. Bag-case: 1 pc. Charger: 1 pc. Ia2.778.042 RE Operating Manual: 1 copy. Ia2.778.042 FO Form: 1 copy. Ia2.778.042 MP Verification instructions: 1 copy. Extended version: Additionally, it can be equipped with a Bluetooth® module for communication with a PC and software for receiving and processing data. It can also be equipped with a small-sized converter.
Produced in: Moscow
Software and hardware complex with a set of sensors for physics classrooms
Software and hardware complex with a set of sensors for physics classrooms
The software and hardware complex with a set of sensors for physics classrooms is designed to measure physical quantities during demonstration work on various sections of physics, as well as to perform experimental work on physics. The set of units of the measuring system is compatible with a PC, has software with an instruction manual. The sensor kit includes 10 sensors for measuring the following physical quantities: - temperature sensor DTV-1 (measuring range -200C + 1100 S); - air humidity sensor DTV-1 (measuring range 10-100%); - pressure sensor DD-1 (measuring range 0-700 kPa); - acceleration sensor DUIMP-1 (measuring range - 4 – + 4 g); - permanent magnetic field induction sensor DUIMP-1 (- 8 – + 8 Gs); - illumination sensor DSCH-1 (measuring range 1 -60 000 lux); - distance sensor DR-1 (measuring range 0.04 – 4.0 m); - angular velocity sensor DUPUS-1 (remote) (measuring range 0 – 210 0/ c); - rotation angle sensor DUPUS-1 (measuring range ±3600); - flame temperature sensor DTP-1 (measuring range 100 – 11000 S).
MNIPI
Minsk
Produced in: Belarus, Minsk
POWDIX 600 X-ray powder diffractometer
POWDIX 600 X-ray powder diffractometer
A feature of the POWDIX 600 X-ray diffractometer scheme is the vertical Bragg-Brentano optical scheme with a fixed horizontal sample position, which makes working with powdery materials, gels and other viscous substances more practical and convenient. The high detector resolution and precise positioning of the POWDIX 600 X-ray goniometer achieve an accuracy better than +/- 0.02° (2θ) over the entire angular range. In the POWDIX 600 diffractometer, the X-ray tube is cooled by an integrated closed water circuit, which can be serviced by any laboratory employee. A wide variety of sample holders (holder for massive samples, holder with rotation, phoneless cuvettes) expands the functionality of the POWDIX 600 and makes it an invaluable tool for scientific research in solid-state physics, materials science, chemistry, geology and other fields of science The diffractometer is included in the Russian State Register of Measuring Instruments.
Produced in: Belarus, Minsk
Laboratory scales VLTE-2100/5100S
Laboratory scales VLTE-2100/5100S
from 87 490 ₽
Technical characteristics: NIP, G2100/5100 Discreteness, g0,01/0,1 Calibration, self-calibration The size of the scale bowl / platform, mm175x145 The smallest weighing limit, g0.5/5.0 The price of the verification scale division, mg100/1000 Limits of permissible error during initial verification, mgot 0.5g to 500g incl. ±50/±500; sv. 500g to 2000g incl. ±100/±500; sv. 2000g to 2100g incl. ±150/±500; sv. 2100g to 5000g incl. ±500; sv. 5000g to 5100g incl. ±1000 according to GOST OIML R 76-1-2011 Accuracy class according to GOST OIML R 76-1-2011II is high The weight adjustment is built-in The time of setting the readings, s, no more than ~3 /~2 7 years warranty
Gosmetr
Saint Petersburg
Produced in: Saint Petersburg
Sound and Vibration Analyzer ASHV-004
Sound and Vibration Analyzer ASHV-004
Designed for measuring and spectral analysis of sound and vibration. Description: Small dimensions and weight High measurement accuracy (Class I according to IEC 61672-1:2002) Three-channel vibration parameter meter Built-in digital octave and third octave filters USB interface Graphic LCD display with backlight Powered by the built-in battery or network adapter.
MNIPI
Minsk
Produced in: Belarus, Minsk
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
Universal energy dispersive X-ray fluorescence spectrometer BRA-135F
The XRF analyzer BRA-135F is an energy dispersive spectrometer which can simultaneously determine the presence of up to twenty chemical elements - from 9F to 92U - in the analyzed sample. Samples can be in liquid, solid, powdered or deposited on a substrate. The analyzer captures concentrations from tenths of mg/kg. The model BRA-135F performs quantitative/semi-quantitative spectral analysis of steel and alloys. It also performs spectral analysis of oil, petroleum and other petroleum products, detecting in their composition even the smallest concentrations of impurities of various metals. The vacuum sample chamber and ultra-slim detector inlet provides a low detection limit in the range of light elements from 9F to 17Cl. The high-performance silicon drift detector (SDD) with an energy resolution of less than 135eV allows the separation of spectral lines of almost all elements, which makes the analysis of complex multicomponent substances (high-alloy steels, precision alloys, polymetallic ores, etc.) possible.
Burevestnik
Kolomyagi
Produced in: Saint Petersburg
 Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
Magnetometer - Measuring Residual Magnetization ION-3701 Conveyor
It is a modern high-precision device (a variant of the ION-3701 device) and used for a wide range of tasks in areas where it is necessary to determine the magnitude of the magnetic field and residual magnetization in shop conditions, on the conveyor, during acceptance and inspection of parts and workpieces. It is equipped with a three-dimensional magnetic field sensor and has outstanding technical characteristics and extensive functionality.
NPP "ELEKTRONNYE PRIBORY"
Naberezhnye Chelny
Produced in: Tatarstan, Naberezhnye Chelny
AF011B Microassembly
AF011B Microassembly
A high-speed signal limiter amplifier. Designed for use in electronic counting frequency meters. Description: The magnitude of the input signals for selecting the switch input and inverting the signal of the limiter amplifier at a supply voltage of ± 5 V: - logical "0" not more than 0.2 V; - logical "1" at least 4.8 V. The value of the input signals of switching on / off the switch at a supply voltage of ± 5 V: - logical "0" no more than 3.3 V; - logical "1" at least 4.1 V. The magnitude of the output signals of the switch at a supply voltage of ± 5 V and a load of 300 ohms connected to zero potential: - logical "0" from 3.1 V to 3.4 V; - logical "1" from 4.0 V to 4.3 V. The minimum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz should be no more than 30 mV. The maximum input voltage of the sinusoidal shape in the frequency range from 10 Hz to 200 MHz must be at least 1 V. The value of the supply voltage: - positive 5±0.2 V; - negative -5±0.2 V. The current consumption should be no more than: - from a positive power source 110 mA; - from a negative power supply 35 mA.
MNIPI
Minsk
Produced in: Belarus, Minsk