Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
Vacuum combined chemical-resistant membrane pump PL.HM02 up to 10 or 50x2 mbar Primelab
from 145 000 ₽
1 supp.
Characteristics Valve(s) material Standard: chloroprene copolymer NO-68-1 (TU 38 0051166-98) A country Russia Overall dimensions, L×W×H, mm 322x140x200 Protection class acc. to DIN EN60529 IP20 Noise level, dB 75 dBA Nutrition 230 V, 50 Hz Material working chamber PTFE (fluoroplastic) Ultimate vacuum, mbar abs. 10 for serial, 50 for parallel, 50x2 for independent connection Excess pressure, bar. Maximum permissible excess operating pressure 0.5 bar Productivity, l/min 76 with parallel, 38 with serial, 38x2 with independent connection Maximum current, A 1.2 Equipment Vacuum pump, cable, instructions, passport, packaging (vacuum regulator and spare parts are not included in the kit and must be ordered separately). Device weight, kg 8.6
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Generator of pure nitrogen and zero air GCHA-18D-60V
Generator of pure nitrogen and zero air GCHA-18D-60V
from 330 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than, 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol.(0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol. (7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 60 liters/hour (1000 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift work is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x425x510 mm Weight is not more than 25 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Vacuum membrane pump PL.HM04.02.01 Primelab
Vacuum membrane pump PL.HM04.02.01 Primelab
from 490 000 ₽
Vacuum membrane pump PL.HM04.02.01 PrimeLab is a compact laboratory device with which you can create a vacuum in the laboratory. It is equipped with innovative membrane technology that ensures high gas pumping speed. Suitable for pumping vapors and gases up to 1 mbar. The PL.HM04.02.01 pump has an excellent safety system. Protection against overheating and overload is provided. All contacting media are made of PTFE, which has rare chemical and physical properties. All control is carried out through vacuum control, which also ensures maximum accuracy and control of all operating parameters. It has a low noise level (75 dB), which does not cause discomfort to the working class.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Pure nitrogen generator GCHA-120
Pure nitrogen generator GCHA-120
from 382 800 ₽
GCHA-120 nitrogen generators are designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments, boxes with an inert atmosphere. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) Volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm)* (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is at least 120 (2.0 l/min), l/h Nominal nitrogen output pressure (with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/h, 3600 (60 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 230x580x680; Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure nitrogen generator GCHA-60
Pure nitrogen generator GCHA-60
from 342 000 ₽
The pure nitrogen generator (hereinafter referred to as the generator) is designed to produce in laboratory conditions nitrogen of the highest purity that is used to power analytical instruments (chromatographs, including those equipped with an electronic capture detector, express analyzers of hydrogen content in metals, organic carbon concentration meters, sample evaporators, etc.). Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.999 Volume fraction of oxygen is not more than, % vol. 0.0005 (5 ppm) Volume fraction of water vapor is not more than, % vol. 0.0007 (7 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) * (with a methane content in the supply air of not more than 4 ppm) 0.0003 (3 ppm) Maximum nitrogen capacity is not less than 60 l/hour (1.0 l/min) Nominal output pressure of nitrogen with the throttle open) is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min. Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than, l/hour, 1800 (30 l/min) Power consumption is not more than, VA, 100 Overall dimensions, (width x depth x height) are not more than, mm, 220x540x670 Weight is not more than, kg 32 Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
META-CHROME AIR COMPRESSORS
META-CHROME AIR COMPRESSORS
The KOV-4 type air compressor is designed to supply flame detectors of gas chromatographs with air. Technical specifications: Capacity, at least, l/min 3 Outlet air pressure, 0.25+5 MPa% Pressure stability at constant flow rate, not more than 0.0007 MPa Engine power consumption, max, VA 100 Receiver volume, l 9 Noise level, no more, 60 dBa Weight, not more than, kg 19 Overall dimensions (width×depth×height), not more than, mm 235×755×440 Single-phase mains voltage 220 V, 50 Hz
Produced in: Yoshkar-Ola, Mari El
Pure Air Generator GCHV-2.0-3.5
Pure Air Generator GCHV-2.0-3.5
from 200 400 ₽
The generators are designed to supply analytically clean air to flame ionization detectors and gas analyzers. They are available in two versions depending on performance and output pressure. Thanks to the presence of a system of catalytic purification of air from hydrocarbons, the generator can significantly improve the accuracy and sensitivity of chromatographic analyses. Technical specifications Air capacity reduced to normal conditions is not less than 2.0 l/min Outlet air pressure is 355 ± 5% kPa (3.5 ati) Output pressure stability at constant flow rate is not worse than ± 10 kPa The stability of the output pressure when the flow rate changes from 0.3 to the maximum value is not worse than ± 10 kPa Output concentration of hydrocarbons is not more than 0.1 ppm Water vapor concentration at 20°C and 100 kPa is no more than 10 ppm Ready time after switching on is no more than 30 min Power consumption is not more than 200 VA Overall dimensions of the generator (width x depth x height) are not more than 230x425x510 mm The mass of the generator is not more than 18 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Vacuum membrane pump PL.HM03.02.45 Primelab
Vacuum membrane pump PL.HM03.02.45 Primelab
from 110 000 ₽
Vacuum membrane pump PL.HM03.02.45 Primelab is an effective device for creating a vacuum, pumping gases and vapors. It has a high pumping speed (38 l/min) with a maximum residual pressure of 45 mbar. All materials in contact with the working fluid are made of PTFE. This material has rare chemical and physical properties. In this case, the pump does not require regular maintenance. Ease of use and reliability make the PL.HM03.02.45 diaphragm vacuum pump an ideal option for laboratories of any scale and production that require high-quality and controlled evacuation.
Primelab
Mytishchi
Produced in: Mytishchi, Moscow region
Dry Air Compressor KSV-6/450
Dry Air Compressor KSV-6/450
from 195 600 ₽
The oil-free compressor is designed to supply air to laboratory nitrogen and oxygen generators, purge optical systems of laboratory devices with dry air, etc. A feature of the device is the presence of a built-in automatic regeneration system of the air drying filter, which frees the user from routine maintenance. Small dimensions, low noise level, lack of maintenance work allow the compressor to be placed in the laboratory room and make working with it easy. Technical specifications Rated output, reduced to normal conditions is 7.0 l/min Maximum output, reduced to normal conditions is 9.0 l/min The range of the set output pressure is from 1.0 to 6.0 ati Output pressure stability at constant flow rate is not worse than ± 0.2 ati Stability of the output pressure when the flow rate changes from 0.5 to the maximum value is not worse than ± 0.4 ati The dew point of the outlet air at an ambient temperature of 20 ° C and rated capacity is not higher than minus 30 ° C The dew point of the outlet air at an ambient temperature of 20 ° C and maximum performance is not higher than minus 15 ° C Volume of the built-in receiver is 6 l The noise level of the device is not more than 50 db Ready time after switching on is no more than 10 min Power consumption is not more than 600 VA Overall dimensions of the device (width x depth x height) are not more than 230x580x530 mm Weight of the device is not more than 27 kg Working conditions: ambient temperature, °C from +10 to +35 relative humidity of the ambient air, % 80 power supply from a single-phase network: AC voltage, 220 ± 10% and frequency, Hz 50 ± 1
Produced in: Moscow
Pure Hydrogen Generator GVCH-9M
Pure Hydrogen Generator GVCH-9M
from 158 400 ₽
The characteristics of the device are similar to the GVCH-12D model; the difference is in the absence of a reactor to remove traces of oxygen and the performance, respectively, is 9 / hour (150 ml/min). Optionally equipped with a reactor for using hydrogen as a carrier gas. Technical specifications Purity of hydrogen in terms of dry gas is about 99.998% Concentration of water vapor at 20 OC and 1atm is no more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 9 l/h The time of setting the operating mode, with the output turned off is no more than 15 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 9 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.015 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 80 VA maximum (at startup) is no more than 100 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
GAS FLOW REGULATOR
GAS FLOW REGULATOR
The flow regulator consists of the following parts: Body. It includes a connector for connection to the control controller and fittings for connecting the input and output gas lines. Calorimetric converter. Due to the heating of the gas along the flow section, the temperature difference is determined. The actuator (solenoid valve). The control board. A system of elements responsible for converting the signals that the user submits. TECHNICAL CHARACTERISTICS OF RD The gas pressure at the inlet is (0.4 + 0.04) MPa. Ranges of working gas flow rates — from 5 to 800 ml/min. The ability to specify the type of gas (nitrogen, helium, hydrogen, argon, air). Pressure ranges — from 0.001 to 0.40 MPa with a discreteness of 0.0001 MPa. The deviation of the carrier gas flow rate from the average value is + 1.5% in the flow range from 50 to 100 ml/min and + 0.5 ml/min in the flow range from 3 to 50 ml/min. Relative deviation of the average steady-state gas flow rate from the set value in the range from 3 to 100 ml/min: + 2.5%, but not less than 0.5 ml/min; from 100 to 200 ml/min.: + 5%; from 200 to 800 ml/min.: + 10%. The gas pressure at the inlet is (0.4 + 0.04) MPa. The deviation of the regulated output pressure of the regulator from the set value is not more than 1%.
Produced in: Yoshkar-Ola, Mari El
Pure Nitrogen Generator GCHA-18D-K
Pure Nitrogen Generator GCHA-18D-K
from 408 000 ₽
The characteristics of the device are similar to the GCHA-18D model; The difference is that the oil–free compressor built into the GCHA-18D-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than, min, * 45 Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 300 VA Overall dimensions, (width x depth x height) are not more than, mm 230x470x510 Weight, not more than, kg 25 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow