Search

91 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 11
    Applying
  • 33
    Names
    Loading...
  • 8
    Manufacturer
  • 8
    Made in
  • Additional
    Loading...
View:
91 products
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
Generator of Pure Nitrogen and Zero Air GCHA-21D-72V
from 450 000 ₽
It is intended for obtaining nitrogen of the highest purity and zero air in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I Volume fraction of nitrogen is not less than 99,999 % vol. (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.0005 % vol. (5 ppm) Volume fraction of water vapor in nitrogen is not more than 0.0007 % vol. (7 ppm) The volume fraction of hydrogen in nitrogen is not detected Volume fraction of the sum of carbon-containing compounds in nitrogen in terms of methane is not more than 0.00001 % vol. (0.1 ppm) Maximum nitrogen capacity is not less than 21 liters/hour (350 ml/min) Nominal output pressure of nitrogen is 4 ati Volume fraction of water vapor in the generated air is not more than 0.0007 % vol.(7 ppm) The volume fraction of the amount of hydrocarbons in the produced air in terms of methane is not more than 0.00001 % vol. (0.1 ppm), (with a concentration of methane in the supply air not more than 5 ppm) Maximum air capacity is not less than 72 liters/hour (1200 ml/min) Nominal output air pressure is not less than 3.5 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6.0 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is not less than 5.5 ati Compressed air consumption, at nominal inlet pressure is no more than 480 l/h (8 l/min) Power consumption is not more than 150 VA Overall dimensions, (width x depth x height) are not more than 230x525x510 mm Weight is not more than 28 kg Operating conditions: ambient temperature, ° C, from +10 to +35 electric power supply from a single-phase AC network with voltage, V, 220 ± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator meets the electrical safety requirements of class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
THERMAL DESORBER TDS-2
THERMAL DESORBER TDS-2
TDS-2 is a syringe (see Fig. 1), which is installed on the evaporator of the chromatograph. The device is equipped with a crane that cuts off the carrier gas line when removing the rod with the sorption tube from the thermal desorber. When the tap is open, the stem is lowered to the lower position and the sorption tube is inserted into the evaporator brought to the desired temperature. In the conditions of the upper position of the rod, it is also possible to displace air by purging the sorption tube with a carrier gas. Technical characteristics of TDS-2 The heating time to the desorption temperature is no more than 1 sec. The cooling time when moving to a cold zone is no more than 10 seconds. Outer diameter 5-0.1 mm Dimensions of the sorbent chamber: diameter 3.4+0.3 mm length 52 mm (470 µl) Volume (for solid samples) 90 µl Operating temperature ranges* from 50° to 400 °C Overall dimensions (height with the rod fully extended) 320 mm. Weight 0.325 kg.
Produced in: Yoshkar-Ola, Mari El
CRYOSTATING DEVICES
CRYOSTATING DEVICES
The separation of some substances (the classic case is the separation of oxygen and argon) requires negative temperatures of the thermostat of chromatographic columns. technical specifications The lower temperature limit of the thermostat of columns with a cooling device based on an air conditioner is minus 5 °C. The error in maintaining the temperature of the thermostat of columns with a cooling device based on an air conditioner is + 0.05 °C. The power consumption of the cooling device based on an air conditioner, no more than — 640 VA. Overall dimensions of the cooling device based on the air conditioner, (width × depth × height), no more than — 620×480× 410 mm. The weight of the cooling device based on the air conditioner, no more than 32 kg. The lower limit of the temperature of the thermostat of columns with a liquid nitrogen cryoclap is minus 100 °C. The error of maintaining the temperature of the thermostat of columns with a liquid nitrogen cryoclave (in the temperature range less than 25 °C) + 0.1 °C. The power consumption of a cooling device with a liquid nitrogen cryoclave, no more than — 10 VA. Consumption of liquid nitrogen, not more than 0.1 l/h.
Produced in: Yoshkar-Ola, Mari El
Nitrogen generator GA-200-N
Nitrogen generator GA-200-N
from 320 400 ₽
The GA-200-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-200 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-200, the GA-200-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than, % by volume (including impurities of inert gases — argon, neon, helium) 99.4 Volume fraction of oxygen is not more than, % vol. 0.6 Volume fraction of water vapor is not more than, % vol. 0.002 (20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati is at least 200 l/hour (3.33 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 1800 l/hour(30 l/min) Factory setting of the maximum pressure in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than, VA, 100 Overall dimensions (width x depth x height) are not more than, mm, 230x525x510; Weight is not more than 27 kg. Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
CRYSTAL-2000 CHROMATOGRAPH
CRYSTAL-2000 CHROMATOGRAPH
Technical characteristics: DETECTOR - TYPE OF CHROMATOGRAPH - DETECTION LIMIT, G/S (G/ML) -STANDARD DEVIATION, % - LEVEL OF FLUCTUATIONAL NOISES, A (V) -DRIFT, А/H (V/H) FID Crystall-2000 5×10⁻¹² 2 2×10⁻¹⁴ 4×10 ⁻¹³ TCD Crystall-2000 (5×10⁻⁹) 2 (2×10⁻⁷) (2×10⁻⁵) ADC Crystall-2000 5×10⁻¹⁴ 4 1×10⁻¹² 8×10⁻¹¹ FPD-Р Crystall-2000 2×10⁻¹² 6 2×10⁻¹¹ 4×10⁻¹⁰ FPD-S Crystall-2000 2×10⁻¹¹ 10 2×10⁻¹¹ 4×10⁻¹⁰
Produced in: Yoshkar-Ola, Mari El
Nitrogen generator GA-400-N
Nitrogen generator GA-400-N
from 432 000 ₽
The GA-400-N nitrogen generator (hereinafter referred to as the generator) is a modification of the GA-400 nitrogen generator and is designed primarily to work with a storage tank (receiver) in which a certain "reserve" of nitrogen can be created. Unlike the GA-400, the GA-400-H generator has a built-in pressure monitoring system for nitrogen accumulated in the receiver, which puts the generator into "standby" mode when the maximum pressure value is reached in the receiver, and restarts the generator when the pressure drops below the minimum value. This work allows you to reduce energy consumption and increase the service life of the compressor feeding the generator. Technical specifications Volume fraction of nitrogen is not less than 99.5% by volume (including impurities of inert gases — argon, neon, helium) Volume fraction of oxygen is not more than 0.5 % vol. Volume fraction of water vapor is not more than 0.002 % vol.(20 ppm) Maximum nitrogen capacity, with nitrogen pressure in the storage tank below 2 ati, is not less than 400 l/hour (6.66 l/min) Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 8 ati Minimum inlet air pressure is 5.5 ati Compressed air consumption, at nominal inlet pressure and maximum flow rate is no more than 3000 l/h (50 l/min) Factory setting of the maximum pressure value in the storage tank is 3.5± 0.2 ati Factory setting of the minimum pressure value in the storage tank is 2.4 ±0.4 ati Power consumption is not more than 100 VA Overall dimensions, (width x depth x height) are not more than 230x580x680 mm; Weight is not more than 35 kg Working conditions: ambient temperature, C°, from +10 to +35 Electric power supply from single-phase AC mains voltage, V, 220± 10% and frequency, Hz, 50 ± 1 Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
SPEAKER SWITCHING DEVICES
SPEAKER SWITCHING DEVICES
To switch the nozzle columns, conventional taps (reverse purge, 6-, 8- and 10-port) are used, which, however, are not suitable for switching capillary columns. An alternative way to switch capillary columns is to change the flows in the capillary columns, which is produced by the so-called "Dins switches" (PD). TECHNICAL CHARACTERISTICS of PD The switching time setting range is from 0.1 to 999 min. Switching time is 0.1 s. The dead volume of the crane is less than 1 µl. The temperature of the tap is no more than 350 °C. The pressure in the crane line is not more than 0.4 MPa. Electric power supply — 5 V.
Produced in: Yoshkar-Ola, Mari El
Pure Hydrogen Generator GVCH-12M1
Pure Hydrogen Generator GVCH-12M1
from 190 800 ₽
The characteristics of the device are similar to the GVCH-12A model; the difference is in the absence of an autoregeneration system for fine gas filters. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% The concentration of water vapor at 20 ° C and 1 atm is not more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 12 l/h The time of setting the operating mode, with the output turned off is no more than 30 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 12 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 150 VA maximum (at startup) is no more than 200 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 ± 1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
NV-1500 LX-O Table for chromatograph (1500×700×850)
NV-1500 LX-O Table for chromatograph (1500×700×850)
from 20 657 ₽
The NV-1500 LX-O are specialized laboratory tables on a reinforced metal frame with a countertop width of 1500 mm. They are designed to accommodate heavy instruments, such as chromatographs or other analytical equipment. In the upper right corner of the table there is an electric panel with two sockets. Both sockets with grounding and shutters are designed for current up to 16 A and voltage up to 250 V. Working surface material: porcelain tile. It is moisture-resistant and perfectly withstands high temperatures. It is resistant to prolonged exposure to concentrated acids, alkalis and organic solvents. It has limited resistance to hydrofluoric acid. This is one of the most popular types of countertops for laboratory furniture. The tables have a metal frame painted with durable powder paint. The side laminated panels (chipboard with a thickness of 16 mm) are edged with a durable PVC edge with a thickness of 2 mm, which increases their impact resistance and mechanical strength. The legs of the table are adjustable in height within two centimeters, allowing you to place it even on a rather uneven floor. Dimensions of the table when assembled: 1500×700×850 mm. It is designed for standing work.
NV LAB
Moscow
Produced in: Moscow, Moscow region
TRANSFORMER OIL INPUT DEVICE
TRANSFORMER OIL INPUT DEVICE
When determining the total gas content (air) and humidity of transformer oil, direct injection of transformer oil into the evaporator of the chromatograph is used. The sample volume is up to 25 µl, the evaporator temperature is 250-350 °C. The main problem with such an input is the protection of the chromatographic column from transformer oil. For this purpose, a special evaporator is used with the possibility of oil accumulation at the bottom of the evaporator and its subsequent discharge, and a replaceable pre-column that protects the column from oil residues that have passed the evaporator. technical specifications The volume of the evaporator is 10 ml. The number of replaceable pre—columns in the device kit is 5. The temperature of the evaporator is from 250 to 350 °C. The possibility of draining the transformer oil accumulated in the evaporator.
Produced in: Yoshkar-Ola, Mari El
Pure Nitrogen Generator GCHA-18D-K
Pure Nitrogen Generator GCHA-18D-K
from 408 000 ₽
The characteristics of the device are similar to the GCHA-18D model; The difference is that the oil–free compressor built into the GCHA-18D-K generator provides complete autonomy of the device. The warranty for the device is 18 months, for the built-in compressor - 12 months from the date of sale. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 18 liters/hour (300 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than, min, * 45 Noise level generated by the compressor is no more than 45 dB Power consumption is not more than 300 VA Overall dimensions, (width x depth x height) are not more than, mm 230x470x510 Weight, not more than, kg 25 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow