Search

92 products
View:
  • Selected: 0
    Applying
  • Selected: 0
    Names
    Loading...
  • Selected: 0
    Manufacturer
  • Selected: 0
    Made in
  • Selected: 1
    Additional
    Loading...
All filters
  • 11
    Applying
  • 33
    Names
    Loading...
  • 9
    Manufacturer
  • 9
    Made in
  • Additional
    Loading...
View:
92 products
CRYOEXTRACTOR EVC-2
CRYOEXTRACTOR EVC-2
The device is designed to extract target organic substances from liquid and solid samples. Implements the latest method of sample preparation in chemical analysis - extraction freezing with centrifugation of EVCB (Patents of the Russian Federation RU2303476/2007, RU2564999/2015, Patent of the Kyrgyz Republic KG388/2020, International Application PCT/RU2015/000615). Scope of application - hydrochemistry, chemical and toxicological analysis, biochemistry, food research, etc. technical specifications The temperature range of extraction freezing with centrifugation is from -(minus) 28 to +25 °C. Rotor speed with the possibility of programming the mode 100-8000 rpm Separation factor up to 6600 g Cryoextractor power supply from AC 220 V, 50 Hz Power consumption, not more than 0.3 kW The mass of the cryoextractor is not more than 50 kg Overall dimensions (HxWxD), mmxmmxmm no more than 900x600x600 Number of simultaneously extracted samples (individually on request)
Produced in: Yoshkar-Ola, Mari El
Pure hydrogen generator GVCH-25A
Pure hydrogen generator GVCH-25A
from 402 000 ₽
The characteristics of the device are similar to the GVCH-12A model. The difference is the generator capacity of 25 liters / hour, the purity of the produced hydrogen is lower (99.9995% vol). Technical specifications Purity of hydrogen in terms of dry gas шы about 99.9995% Concentration of water vapor at 20OC and 3 atm is no more than 7 ppm Total hydrogen capacity reduced to normal conditions is 25 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.04 l/h Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 0.5 years Average pump life (for single-shift operation) is at least 0.5 years Power consumption: in stationary mode is no more than 250 VA maximum (at startup) is no more than 280 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is. not more than 18 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 +1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pure Hydrogen Generator GVCH-12A
Pure Hydrogen Generator GVCH-12A
from 303 600 ₽
The device is equipped with an automatic regeneration system of fine filters, which reduces the maintenance of the device to a minimum. In terms of the totality of technical characteristics and ease of operation, it has no equal among similar laboratory hydrogen generators. The hydrogen capacity is 12 liters/hour (200 ml/min). Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% Concentration of water vapor at 20OC and 1 atm is not more than 5ppm Total hydrogen capacity, reduced to normal conditions is not less than 12 l/h The range of the specified output pressure of hydrogen is from 3.0 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati The time of setting the operating mode, with the output turned off is no more than 30 min Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of the replaceable cartridge of the deionization filter (at maximum performance and single-shift operation) is not less than 1 year Average power consumption: in stationary mode is no more than 180 VA maximum (at startup) is no more than 220 VA Overall dimensions of the generator, (width x depth x height) is not more than 230x470x450 mm The mass of the generator is not more than 16 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage 220 V(+10 -15)% and frequency 50 +1 Hz The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Electronic Gripper (E3D)
Electronic Gripper (E3D)
Selective detector for organochlorine compounds and other halogens. It is also sensitive to compounds containing oxygen, phosphorus or aromatic rings, but to a lesser extent. Paraffins and simple hydrocarbons almost do not capture electrons and are not registered. The selectivity to hydrocarbons is 108. It is available in two versions — conventional EDD and micro-EDD, mainly for capillary columns (the second version is characterized by increased sensitivity). The level of fluctuation noise is up to 300 MV, the maximum signal is up to 5 V, the design of the ECD allows the use of argon, helium, and hydrogen as a carrier gas, in addition to nitrogen. Technical characteristic: 4.0*10-15 g/s for lindane
Produced in: Yoshkar-Ola, Mari El
Pure nitrogen generator GCHA-21D
Pure nitrogen generator GCHA-21D
from 276 000 ₽
An analogue of GCHA-21, but equipped with a built-in system of catalytic purification of the resulting nitrogen from hydrocarbons. GCHA-21D nitrogen generators are designed to produce nitrogen of the highest purity in laboratory conditions. The warranty period of operation of the generator is 18 months from the date of sale by the manufacturer. Technical specifications The grade of nitrogen produced according to GOST 9293-74 is high purity, grade I The volume fraction of nitrogen is not less than, % vol. (including impurities of inert gases: argon, neon, helium) 99,999 The volume fraction of oxygen is not more than, % vol. (ppm) 0.0005 (5 ppm) The volume fraction of water vapor is not more than, % vol. (ppm) 0.0007 (7 ppm) The volume fraction of hydrogen is not more than, % vol. (ppm) 0.0002 (2 ppm) The volume fraction of the sum of carbon-containing compounds in terms of methane is not more than, % vol. (ppm) (with a concentration of methane in the supply air not more than 5 ppm)* 0.00001 (0.1 ppm) Maximum nitrogen capacity is not less than 21 liters/hour (350 ml/min) Nominal output pressure of nitrogen is 4 ati The time of setting the operating mode for single-shift operation is no more than 45 min Nominal inlet air pressure is 6 ati Maximum allowable inlet air pressure is 7 ati Minimum inlet air pressure is 5 ati Compressed air consumption, at nominal inlet pressure is no more than 300 l/h (5 l/min) Power consumption is not more that 110 VA Overall dimensions, (width x depth x height) are not more than, mm 230x425x510 Weight, not more than, kg 25 Working conditions: Ambient temperature, °C from +10 to +35 Electric power supply from a single-phase AC network with a voltage of 220 ± 10% and a frequency of 50 ± 1 Hz Average full service life is at least 6 years The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
Pulsating Discharge Detector(PRD)
Pulsating Discharge Detector(PRD)
It operates in the mode of a helium ionization detector (GID) and is considered the most sensitive device for determining permanent gases. In addition, it is able to work in the EDD mode. Technical characteristic: 2.0*10`13 g/s by. methane or hydrogen
Produced in: Yoshkar-Ola, Mari El
PCU-1 Laboratory catalytic unit
PCU-1 Laboratory catalytic unit
The PCU-1 laboratory catalytic unit is designed to perform the following tasks: 1. Educational and scientific research of chemical processes; 2. Improvement of current industrial processes and development of new ones; 3. Studies of homogeneous and heterogeneous catalysts. The PCU-1 laboratory catalytic unit is manufactured in accordance with the technical requirements of customers so as to correspond to a wide range of technological parameters. Additionally, embedded equipment is designed to control the flow of raw materials and products, as well as data collection and processing. The unit can be subsequently modernized for new purposes. Main advantages: 1. A reliable and high-precision system of control and regulation of technological parameters; 2. Easy replacement of catalyst samples; 3. The possibility of conducting long-term tests in continuous mode; 4. The possibility of upgrading the unit for new purposes; 5. The possibility of conducting tests in flow and flow-circulation modes; 6. Control and accurate reproduction.
Produced in: Rostov region, Novocherkassk
HYDROGEN GENERATORS (75 L)
HYDROGEN GENERATORS (75 L)
These generators are designed to supply hydrogen to flame chromatographic detectors. The produced hydrogen meets the requirements of GOST 3022-80. Technical specifications for GV-75 iGV-75-O: Productivity H2, l/h 0-75 0-75 O2 capacity, l/h - 37 Maximum output pressure, atm 2 2 Hydrogen pressure stability, not worse, atm 0.0025 0.0025 Hydrogen water content, not more than, ppm 5 5 Purity of hydrogen, % 99.995 99.995 Time to enter the mode, min 30 30 Water consumption, g/l H2 1.0 1.0 Working time without refilling water, hour 4 4 Tank volume O2, l 2.5 2.5 The volume of water to be added to the O2 tank when the "Top up water" alarm is triggered is no more than 1,4 1,4 liters Power consumption, max, VA 800 800 Overall dimensions (width×depth×height), not more than, mm 260×438×550 260×438×550 Weight, not more than, kg 25 26
Produced in: Yoshkar-Ola, Mari El
Pure Hydrogen Generator GVCH-12M1
Pure Hydrogen Generator GVCH-12M1
from 190 800 ₽
The characteristics of the device are similar to the GVCH-12A model; the difference is in the absence of an autoregeneration system for fine gas filters. Technical specifications Purity of hydrogen in terms of dry gas is about 99.9999% The concentration of water vapor at 20 ° C and 1 atm is not more than 5 ppm In the output pressure stabilization mode The range of the specified output pressure of hydrogen is from 1.5 to 6.1 ati Stability of the output pressure of hydrogen is not worse than ± 0.02 ati Maximum hydrogen capacity reduced to normal conditions is 12 l/h The time of setting the operating mode, with the output turned off is no more than 30 min In the performance stabilization mode: The range of the specified hydrogen performance is from 0 to 12 l/h Maximum developed pressure in performance mode is 5.0 ati Volume of distilled water to be poured is 1.0 l Distilled water consumption is no more than 0.02 l/hour Water consumption is 1.6 g/l of hydrogen The average life of a replaceable deionization filter cartridge (at maximum performance and single-shift operation) is at least 1 year Average power consumption: in stationary mode is no more than 150 VA maximum (at startup) is no more than 200 VA Overall dimensions of the generator, (width x depth x height) are not more than 230x470x450 mm The mass of the generator is not more than 15 kg Operating conditions: ambient temperature, °C, from +10 to +35 powered by single-phase AC voltage, V, 220 (+10 -15)% and frequency, Hz, 50 ± 1 The generator for electrical safety meets the requirements of Class 1, type H according to GOST 12.2.025-76
Produced in: Moscow
REVERSE PURGE VALVE
REVERSE PURGE VALVE
The reverse purge valve is a 4-way valve designed to change the direction of the flow of the eluent through the nozzle column and blow off heavy components from the beginning of the column in the opposite direction into the detector. The crane is attached to the bottom panel (bottom) of the module, while taking the temperature of the column thermostat. The two upper fittings (see Fig.) are used to connect the column, the other two are connected to the evaporator and the detector.
Produced in: Yoshkar-Ola, Mari El